BL-V35E Instruction Manual: Bar Code Display Interface: Chapter 6 Setting, pages 99 to 108

Pages 99 to 108 of 156, from BL-V35E Instruction Manual: Bar Code Display Interface

The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Keyence BL-V35E

Page 99

Chapter 6 Setting ■ When “Connect Unit” is set to “3) Printer” 3) Printer

Parameter Automatic printout * See p. 126. When this parameter is set to ON, data is automatically printed every time OK or NG is output.

LCD display

Set item

16 Auto Print 0) OFF

0) OFF

1) OK only 0) OFF

1) OK only

2) NG only 3) ON

2) NG only 3) ON

Automatic printout format

17 Auto Print= 0) No. + Data

* See p. 126.

0) No. + Data 1) No, only 2) Data only

Returns to 01 Port 1 Baud.

■ When “Connect Unit” is set to “4) Port 2 Direct” 4) Port 2 Direct

Parameter

LCD display

Set item

6 Infinite

Port 1 receive timer * When the specified amount of time has elapsed, received characters are automatically deleted. This parameter does not normally need to be changed.

Direct display

0.1 to 25.5 S

09 Rcv 1 Timer 5.0S

(Initial value) 5.0S

18 Direct Read

* Sets data from which the serial interface is displayed on the LCD display.

0) Port 2

ENTER key function

19 Enter Key=

* Determines whether a serial output is provided when the [ENTER] key is pressed

0) Out Port 2

0) Port 2 1) Port 1, 2

0) Out Port 1 1) Port OFF

Returns to

2) Out Port 2

01 Port 1 Baud.

* When “4) Port 2 Direct” is selected, direct communication is enabled. Direct communication is described on p.9. Before starting direct communication, the following setting procedure should first be performed. • •

Align the baud rate of serial port 1 to that of the connected personal computer. Align the data format (data length, parity and stop bit) of serial port 1 to that of the connected personal computer.

89

Page 100

Chapter 6

Setting

6.2.3 Communication set mode for serial port 2 ■ Menu list Communication settings for serial port 2 Port 2 Baud Port 2 Form (data length, parity and stop bit) Receive Form Rcv 2 Timer ■ Detailed settings

Parameter

Baud rate

Data format Data length: 7 or 8 Parity: n (none), e (even) or o (odd) Stop bit length: 1 or 2

LCD display

01

Port 2 Baud

3)

9600

02

Port 2 Form

0) 1) 2) 3) 4) 5) 6) 7)

Receive format

Port 2 receive timer * When the specified amount of time has elapsed, received characters are automatically deleted. This parameter does not normally need to be changed.

*

90

03

Receive Form

1)

[data]+CR

02

Rcv 2 Timer

0) stx+[data]+etx 1) [data]+CR 2) esc+[data]+CR

5.0S

Returns to 01 Port 2 Baud.

38400 31250 19200 9600 4800 2400 1200 600

00) 7n1 01) 7e1 02) 7o1 03) 7n2 04) 7e2 05) 7o2 06) 8n1 07) 8e1 08) 8o1 09) 8n2 10) 8e2 11) 8o2

01) 7e1

6

* Align this format to the send data format of the connected bar code reader.

Set item

Infinite 0.1 to 25.5 S (Initial value) 5.0S

Change the parameters according to the connected bar code reader. These parameters do not need to be changed when a BL series bar code reader is used. When a bar code reader manufactured by another company is connected, check its communication specifications and change only the required parameters.

Page 101

Chapter 6 Setting

6.2.4 Main setting mode ■ Menu list Main setting Normal (Normal operation) ............ See p. 32 Parallel output form Max. No. of Presets Auto increment Counter Counter protect Preset active function .................... See p. 46 Max. No. of Presets Auto increment Counter Counter protect Verify step function ........................ See p. 50 Max. No. of Presets Auto increment Counter Counter protect Serial No. check function ............... See p. 54 Serial No. direction Starting digit Max. No. of digits Amount of change Serial No. protect

6

Note: The parameters of the main setting mode cannot be changed when the connected device is set to "Serial 2 Direct" in the Serial 1 Communication setting mode.

91

Page 102

Chapter 6

Setting ■ Detailed settings for Normal (Multi-preset) operation, Preset active function, or Verify step function

Parameter Operation setting

LCD display 01 Mode Setup 0) Normal 0) Normal

Set item

0) Normal 1) Active 2) Varify Step 3) Serial No.

1) Active 2) Verify Step

Parallel output form * See p.45

Max. No. of Presets * Set the maximum number of data presets to be registered.

Auto increment * See p.33

02 Out 1. 0) Bit 03 Max Preset No. MAX 10 04 AutoIncrement 0) ON

0) Bit 1) Binary 2) BCD 0 to 399 (Initial value)10 0) ON 1) OFF

Counter * See p.42

05 Counter 1) OFF

0) ON 1) OFF

1) OFF

6 Counter protect 1 * See p.44

Counter protect 2 * See p.44

Counter protect 3 * See p.44

0) ON

06 Counter Mode1 1) Reset @ OFF 07 Counter Mode2 1) Hold @ Preset 08 Counter Mode3 2. 1) Hold @ Print

0) Reset @ OFF 1) Hold @ OFF 0) Reset @ Preset 1) Hold @ Preset 0) Reset @ Print 1) Hold @ Print

Returns to 01 Mode Setup

1. "02 Out" is displayed only when the "01 Mode Setup" is set to "0) Normal". 2. "08 Counter Mode 3" is displayed only when the device connected to serial port 1 is set to "Printer".

92

Page 103

Chapter 6 Setting ■ Detailed settings for the serial No. check function

Parameter Operation setting

LCD display 01 Mode Setup

Set item 0) Normal 1) Active 2) Verify Step 3) Serial No.

3) Serial No. 3) Serial No.

Serial No. direction

09 No. Direction

0) Forward

* See p. 54.

1) Reverse

1) Reverse

Serial No. start digit

10 Start Digit

1 to 32. 1

* See p. 54.

Serial No. effective digits

11 Max Digits

1 to 6. 6

* See p. 54.

Serial No. increment

(Initial value) 1

-128 to +127.

12 No. Change +1

* See p. 56.

Serial No. protect

13 No. Protect

* See p. 56.

0) Reset

(Initial value) 6

(Initial value) +1

0) Reset 1) Continue 2) Repeat

6

Returns to 01 Port 2 Baud.

93

Page 104

Chapter 6

Setting

6.2.5 Option set mode ■ Menu list Optional settings Beep Digit Specify Max. Digits Start Digit Key (Preset) Key (Cancel) Key (Enter) Input (Preset) Input (Cancel) Input (Enter) Input Type Input Time Input User Out ON Timer Out Delay OUT5-1 User, OUT10-6 User NG Output Preset Output ■ Detailed settings

6

Parameter Buzzer sound

LCD display 01 Beep

* Sets the buzzer output timing. When “ON” is selected, a buzzer sound is output when a key operation is performed or data is read. When “Key Only” is selected, a buzzer sound is output only when a key operation is performed.

0) ON

Digit designation function

02 Digit Specify

* See p. 68.

0) OFF

0) ON 1) Key 2) OFF

1) OFF

Digit designation effective digits

Set item

0) OFF 1) Forward 2) Reverse

Any other than 0) OFF

03 Max. Digits 16

* See p. 68. Continued on the next page.

94

Continued on the next page

Continued on the next page

1 to 32 (Initial value) 16

Page 105

Chapter 6 Setting

Parameter

LCD display

Digit designation start digit

04 Start Digit

Set item

1 to 32 (Initial value) 1

1

*See p. 68.

Key protect * Inadvertent pressing of each key is prevented. When the key protect time is set, each key press is accepted only when the key is pressed and held for the specified period (1 to 5 seconds).

05 Key(Preset) 0) 0 Sec Protect

06 Key(Cancel) 0) 0 Sec Protect

07 Key(Enter) 0) 0 Sec Protect

08 Input(Preset) 0) 0 Sec Protect

09 Input(Cancel) 0) 0 Sec Protect

10 Input(Enter) 0) 0 Sec Protect

Parallel input polarity

11 Input Type

* The input polarity can be changed to between I1 and I5 only.

0) N.O.

Continued on the next page

Continued on the next page

0) 1) 2) 3) 4)

0 Sec Protect 1 Sec Protect 3 Sec Protect 5 Sec Protect OFF

0) 1) 2) 3) 4)

0 Sec Protect 1 Sec Protect 3 Sec Protect 5 Sec Protect OFF

0) 1) 2) 3) 4)

0 Sec Protect 1 Sec Protect 3 Sec Protect 5 Sec Protect OFF

0) 1) 2) 3) 4)

0 Sec Protect 1 Sec Protect 3 Sec Protect 5 Sec Protect OFF

0) 1) 2) 3) 4)

0 Sec Protect 1 Sec Protect 3 Sec Protect 5 Sec Protect OFF

0) 1) 2) 3) 4)

0 Sec Protect 1 Sec Protect 3 Sec Protect 5 Sec Protect OFF

6

0) N.O.

1) N.C.

95

Page 106

Chapter 6

Setting

Parameter

Parallel input time constant

LCD display

Set item

12 Input Time

1 to 99 ms

10ms

(Initial value) 10 ms

Parallel input release to user

00000

0 : Released 1 : Not released * Order: IN5, IN4, IN3, IN2 and IN1

500ms

(Initial value) 500 ms

5ms

(Initial value) 5 ms

13 Input User

* See p.73.

Parallel output ON time

10 to 2550 ms

14 Out ON Timer

* See p.45.

OK/NG output delay time

0 to 255 ms

15 Out Delay

* See p. 45.

Parallel output release to user

16 Out5-1 User 00000

* See p.73.

NG output selection

18 NG Ouput

0 : Released 1 : Not released * Order: OUT10, OUT9, OUT8, OUT7 and OUT6

* Determines whether the NG output is turned on when the verification result is NG (At Verify NG) or when an error such as PLC link error has occurred (At Error). (See p. 144)

0) At Verify NG

0) At Verify NG

Preset output selection

19 Preset Output

* It can be output when the preset data is updated or the preset mode is selected. When “ON at Update” is selected, OUT10 and OK are turned on when the preset data is updated. When “ON in Preset” is selected, the OUT10 remains ON while the preset mode is selected.

0) OFF

17 Out10-6 User 00000

6

96

0 : Released 1 : Not released * Order: OUT5, OUT4, OUT3, OUT2 and OUT1

1) At Error

Returns to 01 Beep

0) OFF 1) ON at Update 2) ON in Preset

Page 107

Chapter 6 Setting

6.3

Initialization of Each Setting Each setting parameter in the BL-V35E can be initialized to the default value set at the time of shipment. ■ Initializing the setting Procedure 1. Select “7) Init” in “Setup”. 5 ) 7 )

Ou t No I n i t

6 )

Re f

2. Select an item to be initialized using the ▼ and ▲ key, and press the [ENTER] key. The following items can be initialized. 1) Init All: Initializes all settings to the default values at the time of shipment. 2) Init Preset: Clears all preset data. 1 ) 2 )

I n i t

A l l

I n i t

P r e s e t

3) Init Out: Initializes parallel settings to the default values at the time of shipment. 4) Init Counter: Initializes all counter values. 3 ) 4 )

I n i t I n i t

6 Ou t Coun t e r

5) nit Ref Data: Clears the reference data. 5 ) 1 )

I n i t I n i t

Re f A l l

Da t a

3. The message shown below is displayed to request confirmation for the initialization. Press the [ENTER] key to execute initialization. Press the [CANCEL] key to cancel initialization.

PRESET

TIM 1 TIM 2 4 3 2 1 OUT

I n i t ?

PRESET No.

DATA

SHIFT ABC..

OPTOIN

7

8

4

5 y e s = E n t e r

N o = C a n c e l

8 7 6 5 OK 10 9 NG

PRESET

KEYENCE

CANCEL

ENTER

1

2

0

CLEAR

PROGRAM

MONITOR

Executes initialization. Cancels initialization.

97

Page 108

Chapter 6

6

98

Setting