Page 89

Chapter 6 Setting This chapter describes in detail the setting procedure for each function of the BLV35E, the setting contents and the meaning of the setting parameters.

6.1

Setting Procedure ............................................................... 80

6.1.1 Starting set mode ................................................................... 80 6.1.2 Exiting set mode .................................................................... 82 6.2

Setting Parameters of the BL-V35E .................................. 83

6.2.1 6.2.2 6.2.3 6.2.4 6.2.5

Menu list ................................................................................ 83 Communication set mode for serial port 1 ............................. 84 Communication set mode for serial port 2 ............................. 90 Main setting mode ................................................................. 91 Option set mode .................................................................... 94

6.3

Initialization of Each Setting .............................................. 97

Page 90

Chapter 6

6.1

Setting

Setting Procedure Set mode is used to change various internal settings of the BL-V35E. This section describes each setting procedure.

6.1.1 Starting set mode Change each setting of the BL-V35E using the following procedure.

Procedure 1. Press and hold the [0] key for 2 seconds. The message shown below appears on the LCD display. The main set mode menu appears.

PRESET

TIM 1 TIM 2

BL - V35

4 3 2 1 OUT

RUN mo d e Se t up

PRESET No.

DATA

SHIFT SYMBOL

OPTION

7

8

4

5

8 7 6 5 OK 10 9 NG

PRESET

CANCEL

ENTER

KEYENCE

1

2

0

CLEAR

PROGRAM

MONITOR

2. Press the ▲ or ▼ key to select the setting menu. The selected setting menu is indicated by "_" below the number. When the ▲ key is pressed several times, the next menu (5 to 7) appears.

6

PRESET

TIM 1 TIM 2 4 3 2 1 OUT

1 ) Po r t 1 3 ) Ma i n

2 ) Po r t 2 4 ) Op t i o n

PRESET No.

DATA

SHIFT SYMBOL

OPTION

7

8

4

5

8 7 6 5 OK 10 9 NG

PRESET

CANCEL

ENTER

KEYENCE

1

2

0

CLEAR

PROGRAM

MONITOR

3. Press the [ENTER] key. When the [ENTER] key is pressed, the parameters of the selected setting menu are displayed. The display below shows the parameters of "3) Main".

PRESET

TIM 1 TIM 2 4 3 2 1 OUT

01 0 )

Mo d e S e t u p N oma l

PRESET No.

DATA

SHIFT ABC..

OPTION

7

8

4

5

8 7 6 5 OK 10 9 NG

PRESET

KEYENCE

80

CANCEL

ENTER

1

2

0

CLEAR

PROGRAM

MONITOR

Page 91

Chapter 6 Setting 4. Select the parameter to be changed. Press the

▲ or key to select the parameter.

▼

PRESET

TIM 1 TIM 2 4 3 2 1 OUT

0 5Co u n t e r 1 ) OF F

PRESET No.

DATA

SHIFT ABC..

OPTION

7

8

4

5

8 7 6 5 OK 10 9 NG

PRESET

CANCEL

ENTER

KEYENCE

1

2

0

CLEAR

PROGRAM

MONITOR

5. Press the [Enter] key to change the parameter setting. "_" appears on the lower line in the display. Press the ▲ or ▼ key to change the parameter setting in the lower line. Continue until the desired parameter setting appears. The parameter indicated by "_" can be changed.

PRESET

P TIM 1 TIM 2 4 3 2 1 OUT

PRESET No.

DATA

SHIFT SYMBOL

OPTION

7

8

4

5

0 5 C o u n t e r 1 ) OF F

8 7 6 5 OK 10 9 NG

PRESET

CANCEL

ENTER

KEYENCE

1

2

0

CLEAR

PROGRAM

MONITOR

Select the parameter setting.

6

6. Press the [ENTER] key to save the parameter setting. When the [CANCEL] key is pressed, the setting is canceled. When the parameter is saved, "_" disappears.

PRESET

P TIM 1 TIM 2 4 3 2 1 OUT

0 5Co u n t e r 1 ) OF F

PRESET No.

DATA

SHIFT SYMBOL

OPTION

7

8

4

5

8 7 6 5 OK 10 9 NG

PRESET

KEYENCE

CANCEL

ENTER

1

2

0

CLEAR

PROGRAM

MONITOR

Press the [Enter] key to save the parameter.

Change the other settings by repeating the above procedure.

81

Page 92

Chapter 6

Setting

6.1.2 Exiting set mode Procedure 1. Press the [CANCEL] key. The main set mode menu appears. From this display, you can select another setting menu to change parameters.

PRESET

TIM 1 TIM 2

1 ) Po r t 1 3 ) Ma i n

4 3 2 1 OUT

2 ) Po r t 2 4 ) Op t i o n

PRESET No.

DATA

SHIFT SYMBOL

OPTION

7

8

4

5

8 7 6 5 OK 10 9 NG

PRESET

CANCEL

1

2

0

CLEAR

PROGRAM

MONITOR

ENTER

KEYENCE

2. Press the [CANCEL] key again. The BL-V35E exits set mode.

PRESET

TIM 1 TIM 2 4 3 2 1 OUT

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

8 7 6 5 OK 10 9 NG

PRESET

KEYENCE

6

CANCEL

ENTER

0

CLEAR

PRGRAM

MONITOR

This completes set mode operation.

82

BL-V35E

Page 93

Chapter 6 Setting

6.2

Setting Parameters of the BL-V35E This section lists the setting menus and parameters of the BL-V35E. For details about each parameter, see the appropriate section.

6.2.1 Menu list Main menu 1) Port 1 ............................................. Communication settings for serial 1 (➮ See p.84) Serial communication Communication settings with a bar code reader PLC link 2) Port 2 ............................................. Communication settings for serial 2 (➮ See p.90) Communication settings with a bar code reader 3) Main

............................................. Main setting mode (➮ See p.91) RUN mode setting Counter setting

4) Option ............................................. Option setting mode (➮ See p.94)

6

Beep Digit designation Key protect Details of parallel Output setting 5) OutNo ............................................. Parallel output setting (➮ See p.71) 6) Ref

............................................. Reference data setting (➮ See p.75)

7) Init

............................................. Initialization of each setting (➮ See p.97)

83

Page 94

Chapter 6

Setting

6.2.2 Communication set mode for serial port 1 ■ Menu list Communication settings for serial port 1 Port 1 Baud Port 1 Form (data length, parity and stop bit length) Connect Unit PC Send Form Send Data Protocol RTS/CTS Rcv 1 Timer Enter Key= BL Reader Receive Form Rcv 1 Timer PLC Link Connected PLC MELSEC-A Station No. Support Unit Block No. SYSMAC-C Unit No. KEYENCE KV DM Address PLC Tim Area Enter Key= Printer Auto Print OFF OK Only Auto Print Form NG Only Auto Print Form ON Auto Print Form Port 2 Direct (direct communication) Rcv 1 Timer Direct Display Enter Key=

6

84

Page 95

Chapter 6 Setting ■ Detailed settings

Parameter

Baud rate

LCD display

01 Port 1 Baud 3) 9600

Data format *Data length: 7 or 8 Parity: n (none), e (even) or o (odd) Sop bit length: 1 or 2

Connected unit * Select an external unit connected to serial port 1.

02 Port 1 Form 01 7e1

Set item 0) 1) 2) 3) 4) 5) 6) 7)

38400 31250 19200 9600 4800 2400 1200 600

00) 7n1 01) 7e1 02) 7o1 03) 7n2 04) 7e2 05) 7o2 06) 8n1 07) 8e1 08) 8o1 09) 8n2 10) 8e2 11) 8o2

03 Connect Unit 0) PC

6

0) PC 1) BL Reader 2) PLC Link 3) Printer 4) Port 2 Direct

When selecting “0) PC”, proceed to p.86. When selecting “1) BL Reader”, proceed to p.87. When selecting “2) PLC Link”, proceed to p.88. When selecting “3) Printer”, proceed to p.89. When selecting “4) Port 2 Direct”, proceed to p.89. Note: When “Connected Unit” is set to “PC” and “Printer”, set the data length to “8 bits”.

85

Page 96

Chapter 6

Setting ■ When “Connect Unit” is set to “0) PC” 0) PC

Parameter Send format * See p.102. When “No Sending” is selected, data is not output.

LCD display 04 Send Form

Send data * See p. 102.

Communication protocol

* See p. 101.

0) 1) 2) 3) 4) 5)

2) [data]+CR

0) No Sending

Set item No Sending stx+[data]+etx [data]+CR [data]+CRLF esc+[data]+CR esc+[dat]+CRLF

Any other than 0)

05 Send Data 0) Bar Code Data

0) 1) 2) 3)

Bar Code Data Preset No. Out No. Ref Data

06 Protocol 0) No Handshaking

0) No Handshaking 1) PASS/RTRY 2) ACK/NAK

RTS/CTS protocol

08 RTS/CTS

* See p. 101.

0) OFF

0) OFF 1) ON

6 Port 1 receive timer

09 Rcv 1 Timer

* When the specified amount of time has elapsed, received characters are automatically deleted. This parameter does not normally need to be changed.

5.0S

ENTER key function

19 Enter Key=

0) Out Port 1

* Determines whether a serial output is provided when the [ENTER] key is pressed

0) Out Port 1

1) Out OFF

Returns to 01 Port 1 Baud

86

Infinite 0.1 to 25.5S (Initial value) 5.0S

Page 97

Chapter 6 Setting ■ When “Connected Unit” is set to “1) BL Reader” 1) BL Reader

Parameter Receive format * Align this format to the send data format of the connected bar code reader.

LCD display

Set item

07 Receive Form

0) stx+[data]+etx

1) [data]+CR

1) [data]+CR 2) esc+[data]+CR Infinite

Port 1 receive timer * When the specified amount of time has elapsed, received characters are automatically deleted. This parameter does not normally need to be changed.

*

09 Rcv 1 Timer

5.0S

0.1 to 25.5S (Initial value) 5.0S

Returns to

01 Port 1 Baud

Change the parameters according to the connected bar code reader. These parameters do not need to be changed when a BL series bar code reader is used. When a bar code reader manufactured by another company is connected, check its communication specifications and change only the required parameters.

6

87

Page 98

Chapter 6

Setting ■ When “Connect Unit” is set to “2) PLC Link” 2) PLC Link

Parameter Connected PLC

LCD display

Set item

10 Connected PLC 0) MELSEC-A

0) MELSEC-A 1) SYSMAC-C 2) KEYENCE KZ

0) MELSEC-A 11 Station No.

Station No.

0

0 to 31 (Initial value) 0

1) SYSMAC-C 12 Support Unit 0) Data Register

Support device * See p. 113

Block No

1) KEYENCE KZ

* See p. 113

Unit No.

DM head address * See p. 116

6

PLC timing area * See p. 116

ENTER key function * Determines whether data is output when the [ENTER] key is pressed

*

88

14 DM Address 0000 15 PLC Tim Area 0) OFF 19 Enter Key= 0) Out Port 1 Returns to

0) Data Register 1) File Register

13 Block No. 0

0 to 255 (Initial value) 0

11 PLC Unit No. 0

0 to 31 (Default) 0

0000 to 9900 (Initial value)0000

0) OFF 1) ON

0) Out Port 1 1) Out OFF

01 Port 1 Baud.

“13 Block No.” is displayed only when “12 Support Unit” is set to “1) File Register”.