BL-V35E Instruction Manual: Bar Code Display Interface: Chapter 6 Setting, pages 89 to 98
Pages 89 to 98 of 156, from BL-V35E Instruction Manual: Bar Code Display Interface
The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Keyence BL-V35E
Page 89
Chapter 6 Setting This chapter describes in detail the setting procedure for each function of the BLV35E, the setting contents and the meaning of the setting parameters.
6.1
Setting Procedure ............................................................... 80
6.1.1 Starting set mode ................................................................... 80 6.1.2 Exiting set mode .................................................................... 82 6.2
Setting Parameters of the BL-V35E .................................. 83
6.2.1 6.2.2 6.2.3 6.2.4 6.2.5
Menu list ................................................................................ 83 Communication set mode for serial port 1 ............................. 84 Communication set mode for serial port 2 ............................. 90 Main setting mode ................................................................. 91 Option set mode .................................................................... 94
6.3
Initialization of Each Setting .............................................. 97
Page 90
Chapter 6
6.1
Setting
Setting Procedure Set mode is used to change various internal settings of the BL-V35E. This section describes each setting procedure.
6.1.1 Starting set mode Change each setting of the BL-V35E using the following procedure.
Procedure 1. Press and hold the [0] key for 2 seconds. The message shown below appears on the LCD display. The main set mode menu appears.
PRESET
TIM 1 TIM 2
BL - V35
4 3 2 1 OUT
RUN mo d e Se t up
PRESET No.
DATA
SHIFT SYMBOL
OPTION
7
8
4
5
8 7 6 5 OK 10 9 NG
PRESET
CANCEL
ENTER
KEYENCE
1
2
0
CLEAR
PROGRAM
MONITOR
2. Press the ▲ or ▼ key to select the setting menu. The selected setting menu is indicated by "_" below the number. When the ▲ key is pressed several times, the next menu (5 to 7) appears.
6
PRESET
TIM 1 TIM 2 4 3 2 1 OUT
1 ) Po r t 1 3 ) Ma i n
2 ) Po r t 2 4 ) Op t i o n
PRESET No.
DATA
SHIFT SYMBOL
OPTION
7
8
4
5
8 7 6 5 OK 10 9 NG
PRESET
CANCEL
ENTER
KEYENCE
1
2
0
CLEAR
PROGRAM
MONITOR
3. Press the [ENTER] key. When the [ENTER] key is pressed, the parameters of the selected setting menu are displayed. The display below shows the parameters of "3) Main".
PRESET
TIM 1 TIM 2 4 3 2 1 OUT
01 0 )
Mo d e S e t u p N oma l
PRESET No.
DATA
SHIFT ABC..
OPTION
7
8
4
5
8 7 6 5 OK 10 9 NG
PRESET
KEYENCE
80
CANCEL
ENTER
1
2
0
CLEAR
PROGRAM
MONITOR
Page 91
Chapter 6 Setting 4. Select the parameter to be changed. Press the
▲ or key to select the parameter.
▼
PRESET
TIM 1 TIM 2 4 3 2 1 OUT
0 5Co u n t e r 1 ) OF F
PRESET No.
DATA
SHIFT ABC..
OPTION
7
8
4
5
8 7 6 5 OK 10 9 NG
PRESET
CANCEL
ENTER
KEYENCE
1
2
0
CLEAR
PROGRAM
MONITOR
5. Press the [Enter] key to change the parameter setting. "_" appears on the lower line in the display. Press the ▲ or ▼ key to change the parameter setting in the lower line. Continue until the desired parameter setting appears. The parameter indicated by "_" can be changed.
PRESET
P TIM 1 TIM 2 4 3 2 1 OUT
PRESET No.
DATA
SHIFT SYMBOL
OPTION
7
8
4
5
0 5 C o u n t e r 1 ) OF F
8 7 6 5 OK 10 9 NG
PRESET
CANCEL
ENTER
KEYENCE
1
2
0
CLEAR
PROGRAM
MONITOR
Select the parameter setting.
6
6. Press the [ENTER] key to save the parameter setting. When the [CANCEL] key is pressed, the setting is canceled. When the parameter is saved, "_" disappears.
PRESET
P TIM 1 TIM 2 4 3 2 1 OUT
0 5Co u n t e r 1 ) OF F
PRESET No.
DATA
SHIFT SYMBOL
OPTION
7
8
4
5
8 7 6 5 OK 10 9 NG
PRESET
KEYENCE
CANCEL
ENTER
1
2
0
CLEAR
PROGRAM
MONITOR
Press the [Enter] key to save the parameter.
Change the other settings by repeating the above procedure.
81
Page 92
Chapter 6
Setting
6.1.2 Exiting set mode Procedure 1. Press the [CANCEL] key. The main set mode menu appears. From this display, you can select another setting menu to change parameters.
PRESET
TIM 1 TIM 2
1 ) Po r t 1 3 ) Ma i n
4 3 2 1 OUT
2 ) Po r t 2 4 ) Op t i o n
PRESET No.
DATA
SHIFT SYMBOL
OPTION
7
8
4
5
8 7 6 5 OK 10 9 NG
PRESET
CANCEL
1
2
0
CLEAR
PROGRAM
MONITOR
ENTER
KEYENCE
2. Press the [CANCEL] key again. The BL-V35E exits set mode.
PRESET
TIM 1 TIM 2 4 3 2 1 OUT
PRESET No.
DATA
COUNT
SHIFT SYMBOL
OPTION
BACK SPACE
7
8
9
4
5
6
1
2
3
8 7 6 5 OK 10 9 NG
PRESET
KEYENCE
6
CANCEL
ENTER
0
CLEAR
PRGRAM
MONITOR
This completes set mode operation.
82
BL-V35E
Page 93
Chapter 6 Setting
6.2
Setting Parameters of the BL-V35E This section lists the setting menus and parameters of the BL-V35E. For details about each parameter, see the appropriate section.
6.2.1 Menu list Main menu 1) Port 1 ............................................. Communication settings for serial 1 (➮ See p.84) Serial communication Communication settings with a bar code reader PLC link 2) Port 2 ............................................. Communication settings for serial 2 (➮ See p.90) Communication settings with a bar code reader 3) Main
............................................. Main setting mode (➮ See p.91) RUN mode setting Counter setting
4) Option ............................................. Option setting mode (➮ See p.94)
6
Beep Digit designation Key protect Details of parallel Output setting 5) OutNo ............................................. Parallel output setting (➮ See p.71) 6) Ref
............................................. Reference data setting (➮ See p.75)
7) Init
............................................. Initialization of each setting (➮ See p.97)
83
Page 94
Chapter 6
Setting
6.2.2 Communication set mode for serial port 1 ■ Menu list Communication settings for serial port 1 Port 1 Baud Port 1 Form (data length, parity and stop bit length) Connect Unit PC Send Form Send Data Protocol RTS/CTS Rcv 1 Timer Enter Key= BL Reader Receive Form Rcv 1 Timer PLC Link Connected PLC MELSEC-A Station No. Support Unit Block No. SYSMAC-C Unit No. KEYENCE KV DM Address PLC Tim Area Enter Key= Printer Auto Print OFF OK Only Auto Print Form NG Only Auto Print Form ON Auto Print Form Port 2 Direct (direct communication) Rcv 1 Timer Direct Display Enter Key=
6
84
Page 95
Chapter 6 Setting ■ Detailed settings
Parameter
Baud rate
LCD display
01 Port 1 Baud 3) 9600
Data format *Data length: 7 or 8 Parity: n (none), e (even) or o (odd) Sop bit length: 1 or 2
Connected unit * Select an external unit connected to serial port 1.
02 Port 1 Form 01 7e1
Set item 0) 1) 2) 3) 4) 5) 6) 7)
38400 31250 19200 9600 4800 2400 1200 600
00) 7n1 01) 7e1 02) 7o1 03) 7n2 04) 7e2 05) 7o2 06) 8n1 07) 8e1 08) 8o1 09) 8n2 10) 8e2 11) 8o2
03 Connect Unit 0) PC
6
0) PC 1) BL Reader 2) PLC Link 3) Printer 4) Port 2 Direct
When selecting “0) PC”, proceed to p.86. When selecting “1) BL Reader”, proceed to p.87. When selecting “2) PLC Link”, proceed to p.88. When selecting “3) Printer”, proceed to p.89. When selecting “4) Port 2 Direct”, proceed to p.89. Note: When “Connected Unit” is set to “PC” and “Printer”, set the data length to “8 bits”.
85
Page 96
Chapter 6
Setting ■ When “Connect Unit” is set to “0) PC” 0) PC
Parameter Send format * See p.102. When “No Sending” is selected, data is not output.
LCD display 04 Send Form
Send data * See p. 102.
Communication protocol
* See p. 101.
0) 1) 2) 3) 4) 5)
2) [data]+CR
0) No Sending
Set item No Sending stx+[data]+etx [data]+CR [data]+CRLF esc+[data]+CR esc+[dat]+CRLF
Any other than 0)
05 Send Data 0) Bar Code Data
0) 1) 2) 3)
Bar Code Data Preset No. Out No. Ref Data
06 Protocol 0) No Handshaking
0) No Handshaking 1) PASS/RTRY 2) ACK/NAK
RTS/CTS protocol
08 RTS/CTS
* See p. 101.
0) OFF
0) OFF 1) ON
6 Port 1 receive timer
09 Rcv 1 Timer
* When the specified amount of time has elapsed, received characters are automatically deleted. This parameter does not normally need to be changed.
5.0S
ENTER key function
19 Enter Key=
0) Out Port 1
* Determines whether a serial output is provided when the [ENTER] key is pressed
0) Out Port 1
1) Out OFF
Returns to 01 Port 1 Baud
86
Infinite 0.1 to 25.5S (Initial value) 5.0S
Page 97
Chapter 6 Setting ■ When “Connected Unit” is set to “1) BL Reader” 1) BL Reader
Parameter Receive format * Align this format to the send data format of the connected bar code reader.
LCD display
Set item
07 Receive Form
0) stx+[data]+etx
1) [data]+CR
1) [data]+CR 2) esc+[data]+CR Infinite
Port 1 receive timer * When the specified amount of time has elapsed, received characters are automatically deleted. This parameter does not normally need to be changed.
*
09 Rcv 1 Timer
5.0S
0.1 to 25.5S (Initial value) 5.0S
Returns to
01 Port 1 Baud
Change the parameters according to the connected bar code reader. These parameters do not need to be changed when a BL series bar code reader is used. When a bar code reader manufactured by another company is connected, check its communication specifications and change only the required parameters.
6
87
Page 98
Chapter 6
Setting ■ When “Connect Unit” is set to “2) PLC Link” 2) PLC Link
Parameter Connected PLC
LCD display
Set item
10 Connected PLC 0) MELSEC-A
0) MELSEC-A 1) SYSMAC-C 2) KEYENCE KZ
0) MELSEC-A 11 Station No.
Station No.
0
0 to 31 (Initial value) 0
1) SYSMAC-C 12 Support Unit 0) Data Register
Support device * See p. 113
Block No
1) KEYENCE KZ
* See p. 113
Unit No.
DM head address * See p. 116
6
PLC timing area * See p. 116
ENTER key function * Determines whether data is output when the [ENTER] key is pressed
*
88
14 DM Address 0000 15 PLC Tim Area 0) OFF 19 Enter Key= 0) Out Port 1 Returns to
0) Data Register 1) File Register
13 Block No. 0
0 to 255 (Initial value) 0
11 PLC Unit No. 0
0 to 31 (Default) 0
0000 to 9900 (Initial value)0000
0) OFF 1) ON
0) Out Port 1 1) Out OFF
01 Port 1 Baud.
“13 Block No.” is displayed only when “12 Support Unit” is set to “1) File Register”.