Hand-held Laser Barcode Reader BL-N70 Series User's Manual: 2 Connections

Pages 15 to 20 of 72, from Hand-held Laser Barcode Reader BL-N70 Series User's Manual

The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Keyence BL-N70

Page 15

2 Connections

2

2-1

Connecting the BL-N70VE . . . . . . . . . . . . . . . . 2-2

2-2

Connecting the BL-N70UBE . . . . . . . . . . . . . . . 2-3

2-3

Connecting the BL-N70RE . . . . . . . . . . . . . . . . 2-5

2-4

Connecting the BL-N70RKE . . . . . . . . . . . . . . . 2-6

2-1

Connections

This chapter describes how to connect various BL-N70 series scanners.

Page 16

2-1

Connecting the BL-N70VE

Turn off main power to the PC before proceeding. Power for the BL-N70VE will be supplied through the computer's keyboard receptacle. (BL-N70VE is compatible with PC's running Windows Vista, XP, 2000 or 98) Connect the 6 pin Mini DIN plug (A) to the computer's Keyboard receptacle. Connect the 6-pin Mini DIN receptacle (B) to the plug from a Keyboard (if desired).

2

CAUTION

Connections

BL-N70VE

Do not remove the cables while the computer is turned on as this may cause the computer or BL-N70VE to malfunction.

(B)

PS/2 connector

To keyboard

To computer

(A)

PS/2 connector (Mini DIN 6-pin)

Reference

When connecting a keyboard connector plug to an AT connector, use a commercial AT to PS/2 keyboard conversion adapter for the connection.

z Precautions when using the computer • DO NOT USE THE KEYBOARD WHEN SCANNING BARCODES ! Typing while scanning barcodes will corrupt the data string. • If the computer has multiple language settings, make sure that the input mode is set for half-width alphanumeric characters. • The keyboard specifications can be selected (

2-2 page 3-7).

Page 17

2-2

Connecting the BL-N70UBE

The BL-N70UBE connects to a PC's USB port, power is supplied through the USB port. (BL-N70UBE is compatible with PC's running Windows Vista, XP, 2000 or 98)

BL-N70UBE To computer

2

USB port (A type)

• DO NOT USE THE KEYBOARD WHEN SCANNING BARCODES ! Typing while scanning barcodes will corrupt the data string. • If the computer has multiple language settings, make sure that the input mode is set for half-width alphanumeric characters. • The keyboard specifications can be selected ( page 3-7).

Installing the USB Driver When BL-N70UBE is first connected to a computer running Windows 98, the USB driver installation screen appears. Install the driver by following the directions given on the screen. (This procedure is not necessary when using a computer running Windows Vista/XP/2000).

Note

Connect the barcode reader after turning on the computer to ensure that it is properly detected.

Procedure

1 The "Add New Hardware Wizard" dialog appears and the message "This window searches for new drivers for: USB human interface device" is displayed. Click on the [Next] button.

2 The message "What do you want Windows to do?" is displayed. Select [Search for the best driver for your device (Recommended).] and click on the [Next] button.

2-3

Connections z Precautions when using the computer

Page 18

2-2 Connecting the BL-N70UBE

3 Click on the [Next] button. "USB human interface device" is displayed and the message "Windows driver search for the device:" appears. Click on the [Next] button. Note

The CD-ROM (Windows) may be required at this point.

4 Windows begins installing the driver. When installation is complete, the message

2

"Windows has finished installing the software that your new hardware device requires." appears. Click on the [Finish] button.

Connections

2-4

Page 19

2-3

Connecting the BL-N70RE

The BL-N70RE directly connects to the serial port (RS-232C D-sub 9-pin connector) of a DOS/V computer. Supply power by using the included AC adapter. • Be sure to use the AC adapter provided with the device. Connecting to other CAUTION power sources may cause damage.

• Supply the AC adapter with a power source of AC 120 V ±10%. Using other power sources may cause damage.

BL-N70RE

2 DOS/V computer (D-sub 9-pin)

AC adapter

‹Connector pins for BL-N70RE 54321 9876 D-sub 9-pin (female) #4-40 screws

Pin No.

Symbol

Description

2 3 4 5 6 7 8

SD (TXD) RD (RXD) SG CS (CTS) RS (RTS)

Sends data Receives data N/C Signal ground N/C Ready to send data Request to send data

Signal direction Output Input Input Output z Communication Settings The following values represent factory settings for the BL-N70RE. The settings can be changed ( page 4-22). Make sure that the settings for BL-N70RE and the connected computer are the same. • Baud rate : 9600 bit/s • Data length : 7 bits • Parity : Even • Stop bit : 1 bits • Communication protocol : No protocol

2-5

Connections

To computer

Page 20

2-4

Connecting the BL-N70RKE

BL-N70RKE can be connected to the AutoID data controller DV-90 and to the dedicated communication units BL-U1, BL-U2, and N-42. These components have a regulated 5VDC power supply on Pin 9 of the D-sub connector.

BL-N70RKE

To Keyence products

2 (D-sub 9-pin)

Connections

‹Connector pins for BL-N70RKE 54321 9876 D-sub 9-pin (female) #4-40 screws

CAUTION

Pin No.

Symbol

Description

2 3 4 5 6 7 8 9

RD (RXD) SD (TXD) SG RS (RTS) CS (CTS) Vcc

Receives data Sends data Does not make any connection Signal ground Does not make any connection Request to send data Ready to send data Inputs +5V DC power supply

Signal direction Input Output Output Input Input

Although it may be possible to connect the BL-N70RKE to external power supplies, it is not recommended. Applying more than 5VDC +/-5% may damage the scanner.

z Communication Settings The following values represent factory settings for the BL-N70RKE. The settings can be changed ( page 4-22). Make sure that the settings for BL-N70RKE and the connected equipment are the same. • Baud rate : 9600 bit/s • Data length

: 7 bits

• Parity

: Even

• Stop bit

: 1 bits

• Communication protocol : No protocol

2-6