Page 4

Operating Precautions z Operations • Do not use a voltage other than 5V DC with the BL-N70 series. Doing so may lead to breakdown on the unit. When using the dedicated power sources BLU1, BL-U2, or N-42 use a power supply within the appropriate range for each communication unit. • Be sure to turn the power off to devices attached to the BL-N70 series when you plug or unplug the cables. Failure to do so may cause damage to the BLN70 series. • Do not disassemble or modify the BL-N70 series. Doing so may lead to breakdown on the unit. • Keep the cables away from high-tension cables or power sources. Otherwise, noise could cause malfunctions or accidents. • The BL-N70 series passes the drop impact resistance test, but take care not to expose the unit to excessive shock. • Do not hold the BL-N70 series by its cable. The unit may become damaged.

z Cleaning • Do not allow water, oil, dust, or other foreign substance to stick to the laser emitter/receiver. This may cause read errors. When the BL-N70 series becomes dirty or stained, clean the surface using an eyeglass cleaning cloth or a soft cloth that has been dampened with a specialty cleaner for plastics that can handle acrylic. (Substances such as ethanol can make acrylics cloudy.)

z Operation Environment/Conditions CAUTION

To use the BL-N70 series correctly and safely, avoid installing it in the following locations. Failure to do so may cause fire, electric shock, damage, accidents, or malfunctions. • Locations where the BL-N70 series is exposed to direct sunlight • Locations where the ambient temperature drops below 0°C or exceeds +40°C • Locations where the ambient humidity goes outside of the range of 35 to 85%RH • Locations where the temperature changes rapidly, causing condensation • Locations where there are flammable or corrosive gases • Locations where there is a large amount of airborne dust, salt, iron, and greasy fumes • Locations where the ambient lighting exceeds the regulation range • Locations where the unit may be directly subjected to vibration or impact • Locations where water, oil or chemicals may splash onto the unit • Locations where a strong magnetic or electric field is generated.

z Procedures during Malfunction Turn off the dedicated power source immediately in the following cases. Using the unit in abnormal conditions could cause fire, electric shock, or accidents. Contact your nearest KEYENCE office (listed at the end of the manual) for repair if : • chemicals, debris, or liquids, including water, enter the BL-N70. • the BL-N70 is damaged. • smoke or abnormal odors are emitted from the BL-N70 series.

z For Obtaining the UL Certification Use the NEC Class 2 output power supply for UL application.

2

Page 5

Organization of the Manual

1

Getting Started

This chapter explains the package contents, the names and functions of each part, and the basic methods for operation.

1

2

Connections

This chapter describes how to connect various BL-N70 series scanners.

2

3

Scanning Barcodes

This chapter describes reading data, the format for sending read data, and the connection interfaces.

3

4

Programming BL-N70 Settings

This chapter describes how to change settings on the BL-N70 series.

4

Appendices

This chapter provides specifications, dimensions, settings, and information about replacing the communication cable.

3

Page 6

Table of Contents Introduction Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Operating Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Organization of the Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Chapter 1 Getting Started 1-1

Package Contents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2

1-2

Identifying Part Names and Functions . . . . . . . . . . . . . . . . . . 1-5

1-3

Using Basic Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 Reading a barcode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6

Chapter 2 Connections 2-1

Connecting the BL-N70VE . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2

2-2

Connecting the BL-N70UBE . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3

2-3

Connecting the BL-N70RE . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5

2-4

Connecting the BL-N70RKE . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6

Chapter 3 Scanning Barcodes

4

3-1

Scanning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2

3-2

Trigger Modes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4

3-3

Data Send Format. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5 Data format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5 Inter character delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6

3-4

Interface Settings for RS-232C or Keyboard/USB . . . . . . . . . 3-7 Keyboard/USB settings (BL-N70VE/UBE) . . . . . . . . . . . . . . . 3-7 RS-232C settings (BL-N70RE/RKE). . . . . . . . . . . . . . . . . . . . 3-7

Page 7

Chapter 4 Programming BL-N70 Settings 4-1

Using Program Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2 Setting procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2

4-2

Starting and Ending Program Mode . . . . . . . . . . . . . . . . . . . . 4-3 Start / End Programming Mode . . . . . . . . . . . . . . . . . . . . . . . 4-3 Initialize . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3

4-3

Activating / Deactivating Barcode Symbologies . . . . . . . . . . . 4-4 Symbology settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4 UPC/EAN detailed settings . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6 CODE128 detailed settings . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8 CODE39 detailed settings . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9 CODABAR detailed settings . . . . . . . . . . . . . . . . . . . . . . . . . 4-10 ITF detailed settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11 GS1 Databar Omnidirectional detailed settings . . . . . . . . . . 4-11 GS1 Databar Limited detailed settings . . . . . . . . . . . . . . . . . 4-12 GS1 Databar Expanded detailed settings. . . . . . . . . . . . . . . 4-12

4-4

Trigger Mode Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13

4-5

Buzzer Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14 Tone selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14 Buzzer timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14

4-6

Decode Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15 Decode Match Count settings. . . . . . . . . . . . . . . . . . . . . . . . 4-15 Duplicate Read Prevention settings . . . . . . . . . . . . . . . . . . . 4-16

4-7

Digit Limit Function Settings . . . . . . . . . . . . . . . . . . . . . . . . . 4-17

4-8

Communication Data Format Settings . . . . . . . . . . . . . . . . . 4-20 Data format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-20 Inter character delay settings . . . . . . . . . . . . . . . . . . . . . . . . 4-21

4-9

Communication Interface Settings . . . . . . . . . . . . . . . . . . . . 4-22 Keyboard/USB settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-22 RS-232C settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-22

4-10 Decimal Program Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-24 4-11 Symbology List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-25

5

Page 8

Appendices

6

A-1

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2

A-2

Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-4

A-3

ASCII Code Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-6

A-4

Settings and the Factory Default Values. . . . . . . . . . . . . . . . . A-7 Barcode symbology settings . . . . . . . . . . . . . . . . . . . . . . . . . . A-7 Operation settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-10 Communication data format . . . . . . . . . . . . . . . . . . . . . . . . . A-12 Communication interface settings. . . . . . . . . . . . . . . . . . . . . A-13

A-5

Replacing the Communication Cable . . . . . . . . . . . . . . . . . . A-14