3.3 Setup Software Operating Procedure 3.3.6 Codabar setup
1. Set code length from 3 to 32 including the start/stop character. 2. When you select Send start/stop character, A, B, C, and D are added to the data to be sent. In this case, the following information appears:
You can select lowercase or uppercase for the start/stop character. 3. When you select Inspect check-digit, the following information appears:
Specify the check-digit calculation method and whether or not the check-digit is sent. 4. Set the other parameters in the same manner as for CODE39.
35
Page 44
3.3 Setup Software Operating Procedure 3.3.7 UPC/EAN setup
1. Select Read EAN 8 code, Read UPC-A[EAN13] code or Read UPC-E to enable to read. If you select Read UPC-A[EAN13] code, the following information appears, asking you to select which digits you want to output on UPC-A.
If you select Read UPC-E, the following information appears, asking if you want to send data with the leading zero-suppressed.
2. You can use the same setting procedure as for CODE39 for Max code length output and Specify label orientation. However, the setting range of Effective and Starting in Max code length output is limited to the code length of the readout UPC/E code. • Although the check-digit parameter is not provided on the screen, the system internally calculates it using modulus 10/Weight3. (The calculated data is sent.)
3.3.8 CODE128 setup
1. The setting range of code length depends on the start character type CODEA to C (see page 70). • CODE-A and B --- 1 to 32 • CODE-C --- 2 to 64 The code length does not include the start/stop character or check-digit. Also, FNC1 to 4 (function codes), SHIFT, and CODE-A to C are excluded from the code length.
36
Page 45
3.3 Setup Software Operating Procedure 2. Check that the double-character start pattern is regulated in the UPC/EAN128 standard. It means the combination of start character (CODE-C) and FNC1 (function code 1). The standard specifies that the UPC/EAN-128 bar codes should start with the double character start pattern. Using this parameter, you can specify that reading will not start without the double character start pattern. 3. You can use the same setting procedure as for CODE39 for Max code length output and Direction. However, the setting range of Effective and Starting in Max code length output is 1 to 64 if the start character is CODE-C. • Although the check-digit parameter is not shown on the screen, the system internally calculates it using modulus 10/Weight3. (The calculated data is not sent.)
3.3.9 Trigger input setting
1. Place the mouse cursor at the item to be changed and click it, or move to the target item by pressing [TAB]. Then, change the setting using [Space]. 2. Select Level synchronization or One-shot synchronization as the scanning method. When you select One-shot, the following information appears, asking you to set the scanning time:
Set the scanning time within the range from 1 to 255 (100 ms to 25.5 s). 3. When you select “Test mode initiated with trigger input ON” or “Test mode initiated at startup,” the following information appears, asking you which test mode you want to start:
If you select both “Test mode initiated with trigger input ON” and “Test mode initiated upon power-up,” “Test mode initiated with trigger input ON” is used. 4. In the Command for trigger input parameter, you can freely change the characters for the Trigger ON/OFF command (within 8 characters). Normally, you should use the default setting (Lon, LOff). 5. Click the Return button or press [ENTER] to return to the main setting screen.
Note
Scanning method --> Page 10 Starting the test mode --> Page 17 Trigger ON/OFF command --> Page 51
37
Page 46
3.3 Setup Software Operating Procedure 3.3.10 Communication setting
1. Place the mouse cursor at the item to be changed and click it, or move to the target item by pressing [TAB]. Then, change the setting using [Space]. 2. When setting the header string, delimeter, and read error, click [Communication strings] or press [ENTER] to move to the communication strings setting screen. 3. Click the Return button or press [ENTER] to return to the main setting screen. Note
(Communication) protocol --> Page 47 The setup software does not allow you to set the baud rate to 19200 to 38400 bit/ s. If you want to set the baud rate within this range, use the serial commands (see page 58).
3.3.11 Communication strings setup
1. Place the mouse cursor at the item to be changed and click it, or move to the target item by pressing [TAB]. Then, change the setting using [Space]. 2. Select appropriate values for Header string and Delimiter from among the displayed items. When you select Custom, the following appears: Then, you can enter the desired value from the keyboard (within 5 characters).
38
Page 47
3.3 Setup Software Operating Procedure 3. When you select Default[:] for Partition mark and Intermediate delimiter, these parameters are set as below:
When you select Custom, the following appears: Then, you can enter the desired value from the keyboard (using one character for the partition mark and 5 characters or less for the intermediate delimiter). 4. Input the Read error using the keyboard. You can change the code as desired (within 8 characters). Normally, you should use the default setting (ERROR). You can chose not to send the read error by selecting a null value for the read error. 5. Click the Return button or press [ENTER] to return to the communication setting screen. Note
Header string, delimeter --> Page 48 Partition mark --> Page 21 Intermediate delimiter --> Page 13 Read error --> Page 48
3.3.12 Other setting
1. Place the mouse cursor at the item to be changed and click it, or move to the target item by pressing [TAB]. Then, change the setting using [Space]. 2. By setting Bepper for OK/NG output, the beeper beeps to indicate reading stability during the normal reading operation. 3. To set OK/NG output duration, enter the appropriate numeric value from the keyboard. The setting range is from 1 to 255 (10 ms to 2.55 s). 4. To set Compare with, enter the preset data to be registered from the keyboard. Usually, specify the data within 32 characters. If you are using CODE128 and the start character is CODE-C, you can set the data using up to 64 characters. 5. Click the Return button or press [ENTER] to return to the main setting screen. Note
STABILITY LED --> Page 19 OK/NG output duration --> Page 10 Preset data --> Page 20 39
Page 48
3.3 Setup Software Operating Procedure 3.3.13 Sending Settings 1. Choose Send from the menu bar. The following screen appears.
2. Set the baud rate, data bits, stop bit and parity according the BL-180’s settings. The BL-180’s default settings are shown above. 3. Specify whether the parameter settings are to be saved in the EEPROM or not. If the current settings are not saved in the EEPROM, the setup software will start with the previous settings when the power is turned on again. 4. After setting the communication parameters, click on OK. Data transmission will begin. If a communication error occurs, the following message will appear.
If you are not sure of the communication parameter settings of the BL-180, turn ON the BL-180’s power switch before executing data transmission, and set the communication parameters as shown in step 1. * The BL-180’s communication parameters are set as shown above for 5 seconds after the power is turned ON. (see page 46.)(See p. 58 of the Users’ Manual.) 5. If the setup software is normally exited, it will return to the main setting screen.
3.3.14 Version Display 1. Click on Info on the manu bar. 2. The following screen appears, where you can confirm the version of this setup software.
40
Page 49
3.4 List of Error Messages
3.4 List of Error Messages If an error occurs, the following messages will appear on the screen. Click on OK and delete the error message. Then, take the necessary corrective action. Error message File not found.
The file specified for Open Setting does not exist.
Drive is not ready.
The specified disk is not prepared.
Write protected.
Overwrite protection is set to the disk.
Illegal filename (must be in format of xxxxxxxx.CFG.)
The remaining disk capacity is insufficient. Replace the disk. The file name does not have extension CFG. Enter the file name correctly.
Illegal file.
Use a correct file name.
Path not found.
The pass for the specified file is invalid.
Device not ready.
The specified drive is invalid.
Insufficient memory.
The main memory capacity is insufficient.
Device I/O error
The disk may be damaged or unformatted.
Error during file operation
Insufficient disk space.
Error during setup
Cause of error
The stored file data are incorrect. Specify a correct file name. This is not BL-180 setting file. Data of the BL-180 setup file are different from that of the BL-180. These files are not for common use. The stored file data are damaged. Specify a new file Error in detailed code data. name. An error occurred during communication. The parameter settings (e.g. baud rate) may not be Communication error matched, or the connection may be incorrect. The specified value is exceeding the setting range. Value out of range. Enter a correct value. Min. code length is set larger The minimum code length is set larger than the than Max. code length. maximum code length. Enter a correct number. The serial port is being used for a device other than Device is unavailable. the BL or else “Terminal” is running.
41
Page 50
3.5 How to Use Terminal Software
3.5 How to Use Terminal Software The terminal software allows bar code data to be displayed on a Windows-based personal computer and allows serial commands to be sent to the BL-180. You can use the standard terminal software included in Windows Ver. 3.1. This section describes how to use the terminal software to confirm the operation of the BL-180. For more information on the terminal software and its functions, please refer to theWindows manual. 1. Double-click on the Terminal icon in the Accessory Group.
The terminal software starts up. 2. When the terminal software is started, the following screen appears.
3. First, set the terminal software. When you click on Settings, the following menu appears.
42
Page 51
3.5 How to Use Terminal Software 4. When you click on Terminal Preferences, the setting screen is displayed. Set the displayed parameters as shown below. After setting the parameters, click on OK.
5. Then, Click on Settings then Communications. The following screen appears.
After setting “Connector” to COM1 or COM2, set the baud rate, data bits, stop bits and parity according to the BL-180’s settings. When the data bits is set to “8 bits”, the parity can only be set to “None.” After setting the communication parameters, click on [OK]. 6. When the BL-180 reads a bar code, the read data is displayed on the screen. (When the BL-180’s delimiter is set to CR, data will be displayed with carriage returns. Control codes cannot be displayed.) 7. To send a command, type TEST1/TEST2 using the keyboard, and then press [ENTER]. All commands should be in entered in all uppercase characters. Refer to pages 51 to 52 for available commands and for descriptions of each commnad. In read rate display test mode (TEST 1 mode), the entered command is difficult to see on the screen because the BL-180 is displaying the read data. However, the command will be correctly sent. 8. To exit the terminal software, click on File then Exit. Note
Multi drop link commands cannot be sent. RTS/CTS protocol commands cannot be confirmed. When you start up “Terminal”, you cannot send the setting to BL using SETUP software. Quit on close “Terminal” before you send the setting.
43
Page 52
3.5 How to Use Terminal Software
44