Page 33

Chapter 3 Setup Software

Page 34

3.1 Controlling the BL-180

3.1 Controlling the BL-180 The BL-180 can be controlled by computer using an RS-232C serial communication with Windows™ Terminal software or using BL-180 Setup Software. This chapter describes how to set the BL-180 using the BL-180 setup software. For more information on using the serial communication, see “Chapter 4” on page 45.

3.1.1 Setup Software Requirements The BL-180 Setup Software for Windows operates in the following environments: Personal Computer IBM PC/AT or compatible model (100% compatible) CPU: 80386 or higher Memory: 4 MB or more Floppy drive: One or more 3.5 inch drives RS-232C: One serial port (COM 1 or COM 2) DOS: Windows 3.1 * The BL-180 Setup Software applies to COM 1 only.

Starting the setup software

1. Prepare the following items before starting. • BL-180 • Power supply unit for BL-180 (5 VDC) or the BL-U1 • RS-232C cable described on p. 2 to 4 in this manual • Setup software • Personal computer • Mouse 2. Connect the PC with the BL-180 or BL-U1 using the RS-232C cable. 3. Set the DIP switches on the BL-U1 to RS-232C when you use the BL-U1. 4. Install the setup software. Turn the PC’s power switch ON to start Windows. 5. Insert the setup software into the floppy disk drive. 6. Select File - Run on the menu bar of the program manager.

7. When the following screen appears, type the name of the floppy disk drive and the name of the installed file “SETUP” in the “Command Line”. After typing the above, click on the OK button.

Example

When the floppy drive is drive A, type as follows:

A:\SETUP Then, the target directory for installation is displayed.

“C:\BL180” is displayed. 26

Page 35

3.1 Controlling the BL-180 8. To accept the directory name, click on the OK button. 9. To change the directory name, click on the column displying the directory name, type a desired directory name using the keyboard, and click on the OK buttonAfter the installation is completed, the “KEYENCE Barcode

Reader” window is created in the program manager. In this window, icon “BL18WIN” is created. 10. To start the setup software, double-click on the “BL18WIN” icon.

11. After the setup software gets started, the following screen appears: Note

When using a monochrome display on a laptop PC, the display appears in reverse video. To make the display clearer, set the laptop’s display to reverse video and then restart the setup software.

27

Page 36

3.2 Operating Procedure

3.2 Operating Procedure 3.2.1 Outline of Operation To operate the setup software, place the mouse pointer on the item to be changed, and click the left button of the mouse. Use the Down Arrow button to select an item from a list. Place the mouse pointer on a desired item, and click on the item.

Click on the Option button to select one of several items.

In the above settings, Read mode is set to “Single” and Data-send is set for “At trigger input.” The Check Box is used to enable special functions. An “X” in the Check Box indicates that a function has been enabled.

In the above settings, “Inspect check-digit[Modulus43]” is enabled. To enter characters or a value in a field, insert the mouse pointer over the field. The pointer will change to a cursor. Click inside the field and type in the desired value.

If the specified value exceeds the setting range, an error message will appear To shift to a different screen, click the mouse cursor one of the buttons in the window. For example to return to the previous screen, click on the button.

28

Page 37

3.3 Setup Software Operating Procedure

3.3 Setup Software Operating Procedure After the setup software is started, the following screen (main setting screen) is displayed. The function of each display is as follows. Title (Name of the current setting screen)

Current file name The initial file name is “Untitled. CFG”.

Menu bar (*)

Parameter

Setting screen selector buttons

The setup software provides the following setting screens according to the parameters. Main setting [Main] • Type of the bar code to be read • Read mode and its setup • Decoding match count • Additional information Setting details for the specified code type [Code setup] • Setting No. of bar code length, inspection of check-digit, etc. Trigger input setup [Setup Trigger input] • Setting the operation mode and the trigger input • Selecting the test mode starting method • Setting characters for the trigger ON/OFF command Communication parameters [Setup comm] • Setting the baud rate, data bits, stop bit and parity • Setting the protocol • Setting the Communication strings (header string, delimiter, read error code, etc.) Utility [Utility] • Setting the beeper • Duration of OK/NG output • Registration of preset data For the operating procedure, see “Setup Software Operating Procedure” on page 29. For the error messages displayed during operation, see page 41.

29

Page 38

3.3 Setup Software Operating Procedure Menu Bar

The following operations can be performed using the menu bar. File Menu (Alt+F) Specifies a file name/Saves a file. Exits the setup software. Send Settings (Alt+S) Sends settings to the BL-180. Info (Alt+I) Indicates the version number of this software.

3.3.1 File Operation The following is the procedure for specifying a file name, saving a file or exiting the setup software. Click on File in the menu bar. The following menu appears.

New Cancels the current setting file and calls the initial setting. Open Calls the previously stored file. Save As Saves a file with a specified file name. Save Saves a file. Exit Exits the setup software.

New

1. Click on New. The following message appears.

2. To cancel the current settings and call the initial setting, click on the OK button. If you wish not to execute this operation, click on Cancel .

30

Page 39

3.3 Setup Software Operating Procedure Open

1. Click on Open. 2. The following screen is displayed for selection of the file to be read.

Select a desired file from those listed in the file selection column, and click on the OK button. If you wish to cancel this operation, click on the Cancel button. To change the directory or drive, select a desired directory or drive in the directory/drive selection column. 3. When you click on the OK button on the above screen, the following message appears.

To cancel the current setting and call a new file, click on the OK button. If you wish not to execute this operation, click on the Cancel button.

Save As

1. Click on Save As. 2. The “Save As” screen appears. 3. Click in the file name entry field and type a file name using the keyboard. Type a file name of up to 8 characters. Be sure to add extension “CFG” to the file name.

31

Page 40

3.3 Setup Software Operating Procedure Example

When the file name is “TEST”: 1. Click on the file name entry column. 2. Enter “TEST. CFG” as the file name . 3. Click on the OK button. If you wish cancel this operation, click on the Cancel button. To change the directory or drive, select a desired directory or drive in the directory/drive selection column. 4. If the specified file name has already been stored, the following message will appear.

To save the setting by overwriting the existing file, click on the OK button. If you wish not to save the setting, click on the Cancel button.

Save

A file name must be entered before the file can be saved 1. Click on Save. The file will be saved.

Exit

1. Click on Exit. The following message appears.

2. To exit the setup software, click on the OK button. If you wish cancel, click on Cancel. Save the current settings before exiting the setup software.

3.3.2 Main setting screen

1. Place the mouse cursor at the item to be changed and click it, or move to the target item by pressing [TAB]. Then, change the setting using [Space]. 2. To codes 1 to 4, specify the types of bar codes to be read. If you specify 4 different types of bar codes, the BL-180 can read them without changing the settings. 3. To set the code length or the inspect for check-digit, click Setup or press [ENTER] to move to the setup screen for each code (see page 33 to 36).

32

Page 41

3.3 Setup Software Operating Procedure 4. When selecting Single for Read mode, the following appears on the screen:

When selecting Multi 1 or Multi 2, the following appears on the screen:

Set the time within the range from 1 to 255 (100 ms to 25.5 s). When selecting Multi 3, none of the above information appears. 5. In the Additional information field, you can select one or more items. However, the scan count is given only when the decode count is selected.

Note

Read mode --> Page 12 Data-send --> Page 11 Repeating-reading time --> Page 12 Decoding match count --> Page 10 Additional information --> Page 21

3.3.3 CODE39 setup When setting CODE39 to any one of codes 1 to 4 and trying to set details, this setting screen appears.

1. Place the mouse cursor at the item to be changed and click it, or move to the target item by pressing [TAB]. Then, change the setting using [Space]. 2. Setting Max code length and Min code length allows the BL-180 to read bar codes having the specified range of digits. If you want to read bar codes with the specific code length, set the same value to both Max code length and Min code length. The allowable setting range is 3 to 32 digits including the start/stop character. 3. When you select Send start/stop character, * is added to the data when being sent.

33

Page 42

3.3 Setup Software Operating Procedure 4. When you select Inspect check-digit, the following information appears:

The above setting sends the data together with the check-digit. Modulus 43 is used to calculate the check-digit. 5. When you select Max code length output, the following information appears:

Set Effective and Starting from 1 to 32. 6. When you select Specify label orientation, the following information appears:

7. Click the Return button or press [ENTER] to return to the main setting screen. Note

Max. code length output --> Page 23 Specify label orientation --> Page 16

3.3.4 ITF setup

1. Setup is the same as the CODE39 setup. However, ITF does not have Start/ stop character. 2. Set code length using a even value within the range from 2 to 32. 3. Modulus 10/Weight3 is used to calculate the check-digit. Note

When reading the standard distribution code (bar code on the corrugated fiberboard box), set the code length to 14 or 16 and select the Inspect check-digit.

3.3.5 Setup for Industrial 2 of 5 and COOP 2 of 5 1. Setup is the same as the CODE39 setup. However, a start/stop character and Inspect check-digit are not provided. 2. Set code length within the range from 1 to 32.