The text of a manual · part 7 of 8
SF51 Cordless Scanner User's Guide, pages 61 to 70
Pages 61 to 70 of 76
The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec SF51 Scanner
Page 61
Chapter 4, Configuration Command Reference
Character String
Description
AIM ISO/IEC standard
The AIM Standard for symbology identifiers consists of a three-character structure indicating the symbology and the optional features of the symbology. For more information about the AIM Standard for symbology identifiers, refer to the AIM ISO/IEC Standard.
User-defined ASCII character string
The user-defined symbology identifier (UDSI) is one to four ASCII characters in length. You can configure userdefined symbology identifiers to assign custom identifier strings to the bar code symbologies.
Code Mark
The code mark identifier is a single character user-defined symbology identifier. Its value can range from 0x00 to 0xFF.
Telepen Enables or disables decoding of Telepen symbology. Telepen is the only symbology to directly represent the full ASCII character set without shift characters. It is extremely secure as it has negligible risk of misreads and has a double density numeric only mode.
Timeout Between Different Consecutive Codes Use this command to invalidate a second bar code read that occurs before the timeout expires. Use this command when scanning bar codes that contain different data as opposed to the Timeout Between Identical Consecutive Codes command that you use when your bar codes contain identical data. You can set Timeout Between Different Consecutive Codes to a value from 0 to 2550 ms.
Timeout Between Identical Consecutive Codes Use this command to invalidate a second bar code read that occurs before the timeout expires. Use this command when scanning bar codes with identical data as opposed to the Timeout Between Different Consecutive Codes command that you use when your bar codes contain different data. You can set Timeout Between Identical Consecutive Codes to a value from 0 to 2550 ms. 48
SF51 Cordless Scanner User’s Guide
Page 62
Chapter 4, Configuration Command Reference
TLC 39 TLC 39 is a “composite” symbology designed for the Telecommunications Industry. TLC 39 combines a Code 39 symbol, encoding a part number (for items such as plug-in boards at central switching stations) with a “linked” MicroPDF417 symbol encoding a serial number and other optional information. The first 6 characters must be numeric and include the ECI number. The 7th character is a delimiter between the linear data portion and the composite data portion, typically a comma, but other delimiters are allowed. The next piece of data is a mandatory unique Serial Number. There can be other data fields after the Serial Number, usually either AppIDs or DataIDs, which are governed by whether or not there are alpha characters in the serial number. Country Of Origin is another typical data field that is included in this symbology.
Trigger Mode Trigger mode allows you to set different types of triggering for the scanner. Mode
Description
Continuous/ Edge
When you press the Scan button, the red scanner beam turns and stays on. When you press the Scan button a second time, the scanner turns off. Simply releasing the button does not turn off the scanner.
Level
When you press the Scan button, the red scanner beam turns on and stays on until you release the Scan button or until the SF51 successfully decodes a bar code. When you scan a data bar code, data transmission may be slow if there is interference with Bluetooth communications, or if the SF51 is too far from the host device. While the SF51 is waiting, the scanner beam blinks. During this time, you can scan configuration bar codes but not data bar codes. When the SF51 receives acknowledgement from the host, the scanner turns off, and the SF51 beeps.
SF51 Cordless Scanner User’s Guide
49
Page 63
Chapter 4, Configuration Command Reference Mode
Description
Pulse
When you press the Scan button, the red scanner beam turns on. The scanner remains on until the Trigger Timeout period is reached.
Flashing
When you press the Scan button, the red scanner beam turns on and the SF51 checks for a bar code to read. When the Trigger Timeout period is reached, the scanner starts flashing. When the SF51 finds and reads a bar code, it resets the Trigger Timeout period. If you press the Scan button a second time, the scanner turns off.
Autostand
Autostand mode allows you to switch between level mode and flashing mode. The first time you press the Scan button, the scanner beam turns on and the scanner is in flashing mode. You switch to level mode by pressing the Scan button again. If the scanner is idle and the Trigger Timeout period is reached, the scanner returns to flashing mode.
Aim
Aim triggering allows you to turn on the scanner and aim the red scanner beam without causing a decode. Releasing the Scan button enables the decode. Note: EasySet contains a folder, Predefined Modes, in Operating Settings > Trigger Activation. The commands in this folder are currently not supported on the SF51.
Trigger Timeout Set the Trigger Timeout for the Trigger Mode command. You can set Trigger Timeout from 1 to 4095 seconds.
Turn Off After Good Read Sets how the SF51 operates in level and pulse trigger modes.
Trigger Mode
Turn Off After Good Read
Level
Enabled
The SF51 turns off after it successfully reads a bar code.
Level
Disabled
The SF51 stays on until you release the Scan button.
50
SF51 Behavior
SF51 Cordless Scanner User’s Guide
Page 64
Chapter 4, Configuration Command Reference
Trigger Mode
Turn Off After Good Read
Pulse
Enabled
The SF51 turns off after it successfully reads a bar code.
Pulse
Disabled
The SF51 stays on until the Trigger Timeout period is reached.
SF51 Behavior
UPC/EAN Enables or disables decoding of Universal Product Code (UPC)/ European Article Numbering (EAN) symbology. UPC/EAN are fixed-length, numeric, continuous symbologies that use four element widths. A scanner that is configured to decode EAN bar codes can decode UPC, but the reverse is not true. UPC code is a subset of EAN code.
ISBN ISBN (International Standard Book Number) is a 10-digit symbology that uniquely identifies books for tracking and ordering. With ISBN enabled, the first three characters (978) are ignored, and the checksum is calculated on the remaining characters.
GTIN Processing With GTIN (Global Trade Item Number) processing enabled, two zeros are padded to the beginning of UPC-A, and one zero is padded to the beginning of EAN-13 to expand the numbers to 14 digits. To use GTIN processing you also need to enable the corresponding UPC/EAN symbology.
User Reset Factory Defaults Causes the SF51 to perform a restart and restores all configuration commands to their default settings, only if no settings are locked. To reset all settings on the SF51, including locked settings, use the Administrator Reset Factory Defaults command. For more information, see “Administrator Reset Factory Defaults” on page 38. When you restore all configuration commands to their default settings, you need to reestablish Bluetooth communications.
SF51 Cordless Scanner User’s Guide
51
Page 65
Chapter 4, Configuration Command Reference
Vibrate Alert Enables or disables the vibrate alert. When Vibrate Alert is enabled, the scanner vibrates when you scan a valid bar code.
Vibrate Alert Duration Sets the amount of time that the vibrate alert remains on. You can set Vibrate Alert Duration to a value from 0 to 2550 ms.
52
SF51 Cordless Scanner User’s Guide
Page 66
A Appendix
53
Page 67
Chapter A, Appendix
Specifications Use this section to find technical information about the SF51.
Physical Dimensions Length:
15.7 cm (6.1 in)
Height:
3.4 cm (1.3 in)
Width:
4.6 cm (1.8 in) at the scanner, tapered to 3.2 cm (1.26 in) at the handle
Weight:
263 g (9.3 oz)
Power and Electrical Specifications Operating:
Rechargeable lithium-ion battery
Electrical rating:
x 5V; 1.5A
Temperature and Environmental Specifications
54
Operating:
-20°C to 50°C (-4°F to 122°F)
Storage:
-20°C to 60°C (-4°F to 140°F)
Charging:
0°C to 35°C (32°F to 95°F)
Relative humidity:
0 to 95% non-condensing
Environmental rating:
IP52
SF51 Cordless Scanner User’s Guide
Page 68
Chapter A, Appendix
Bar Code Symbologies • Codabar
• MSI
• Codablock A
• PDF417
• Codablock F
• Plessey
• Code 11
• RSS 14
• Code 39
• RSS 14 Stacked
• Code 93/93i
• RSS Limited
• Code 128 / EAN 128
• RSS Expanded
• EAN.UCC Composite
• Standard 2 of 5
• Interleaved 2 of 5
• Telepen
• Matrix 2 of 5
• TLC 39
• Micro PDF417
• UPC/EAN
Note: PDF417 and Micro PDF417 are only available on the SF51 with PDF version.
Bluetooth Radio Radio Type:
Bluetooth Class 1 version 1.2
Frequency:
2.4 GHz
Radio Data Rate:
721 Kbits per second
Communication Range Host radio Class 1:
30.5 m (100 ft)
Host radio Class 2:
10 m (32.8 ft)
Features:
Adaptive Frequency Hopping (ADF)
EV10 Scanner Scan rate:
200 scans per second
Scan range:
up to 50 cm (19.7 in)
Scan angle:
40 degrees
Minimum X dimension: 4 mils (0.1 mm)
SF51 Cordless Scanner User’s Guide
55
Page 69
Chapter A, Appendix
Accessories for the SF51 You can use these accessories (sold and ordered separately) with the SF51. To order accessories, contact your local Intermec sales representative. Accessory
Description
1-Bay Charger
The 1-bay charger (Model 074645) charges the battery in the SF51 and is designed to be mounted on a horizontal or vertical surface.
1-Bay Charger Power Supply
The power supply for the 1-bay charger (P/N 851-086-xxx) provides AC power to the 1-bay charger. It comes with power supply adapters for Australia, Continental Europe, United Kingdom, North America, Central America, Mexico, and Japan. It also comes with a flat plate for use with an AC power cord. The AC power cord is not included.
4-Bay Charger
The 4-bay charger (Model 074646) has the same functionality of the 1-bay charger, except it allows you to charge up to four SF51 scanners at the same time.
4-Bay Charger Power Supply
The power supply for the 4-bay charger (P/N 851-088-xxx) provides AC power to the 4-bay charger.
USB Bluetooth Adapter
The USB Bluetooth Adapter (P/N 203-771-xxx) provides wireless communications to your host computer and data collection application.
RS-232 Bluetooth Adapter
The RS-232 Bluetooth Adapter (P/N 203-768-xxx) provides wireless communications to your host computer and data collection application through an RS-232 serial port on your PC.
Forearm Holster The forearm holster (P/N 074649) provides you with an easy way to carry the SF51 when you are not using it. The holster supports either right-handed or left-handed use. Chest Strap Holder
Use the chest strap holder (P/N 825-173-xxx) to carry the SF51 when you are not using it.
Industrial belt clip holder
Use the belt clip (P/N 825-172-xxx) to carry the SF51 when you are not using it.
56
SF51 Cordless Scanner User’s Guide
Page 70
I Index
59