Page 260

Control Panel Applets

APPENDIX A

Code 128 Options

Set the following for the Code 128 parameter: Action: Tap (+) to expand the Code 128 parameter, select a setting, then select an option to change this setting. Options: EAN 128 ]C1 Identifier CIP 128 French Pharmaceutical Bar code length Minimum length

0 1 0 1 0 1 001–254

Remove Include (default) Not active (default) Active Any length (default) Minimum length Minimum length 1–254 (6)

700 Series Color Mobile Computer User’s Manual

A-11

Page 261

Control Panel Applets

APPENDIX A

Code 128 FNC1 Character

The Code 128 FNC1 character (EAN 128 norms) can be any ASCII character and is used as a separator when multiple identifiers and their fields are concatenated. Non-printable ASCII characters can be entered using the following syntax where HH is the hexadecimal value of the character. \xHH

For example, the GS character, whose hexadecimal value is 1D, would be entered as \x1D. In addition,the following characters have their own identifiers: BEL BS FF LF CR HT VT

\a \b \f \n \r \t \v

Action: Tap (+) to expand the Code 128 parameter, then type the ASCII characters to be set for the Code 128 FNC1 character parameter. SNMP OID: 1.3.6.1.4.1.1963.15.3.3.1.1.21.1 Options: Any ASCII character (default is the GS function character, ID hex)

A-12

700 Series Color Mobile Computer User’s Manual

Page 262

Control Panel Applets

APPENDIX A

Plessey

Plessey is a pulse-width modulated symbology like most other bar codes. It includes a start character, data characters, an eight-bit cyclic check digit, and a termination bar. The code is continuous and not self-checking. You need to configure two parameters for Plessey code: Start Code and Check Digit. Action: Tap (+) to expand the Plessey parameter, select the setting to be changed, then select an option to change this setting or select an option from the drop-down list. SNMP OID: 1.3.6.1.4.1.1963.15.3.3.1.1.10.1 Options: Decoding Check digit Bar code length Minimum length " NOTE:

0 1 0 1 0 1 001–254

Not active (default) Active Not transmitted (default) Transmitted Any length (default) Minimum length Minimum bar code length 1–254 (6)

If “1” is selected for Bar code length, then Minimum length is entered.

700 Series Color Mobile Computer User’s Manual

A-13

Page 263

Control Panel Applets

APPENDIX A

MSI

MSI is a symbology similar to Plessey code (page A-13) that includes a start pattern, data characters, one or two check digits, and a stop pattern. Action: Tap (+) to expand the MSI parameter, select the setting to be changed, then select an option to change this setting or select an option from the drop-down list. SNMP OID: 1.3.6.1.4.1.1963.15.3.3.1.1.15.1 Options: Decoding Check digit

Bar code length Minimum length " NOTE:

A-14

0 1 0 1 2 3 0 1 001–254

Not active (default) Active Mod 10 transmitted (default) Mod 10 Not transmitted Double Mod 10 transmitted Double Mod 10 not transmitted Any length Minimum length (default) Minimum length 1–254 (6)

If “1” is selected for Bar code length, then Minimum length is entered.

700 Series Color Mobile Computer User’s Manual

Page 264

Control Panel Applets

APPENDIX A

PDF 417

PDF 417 is a stacked two-dimensional symbology that provides the ability to scan across rows of code. Each row consists of start/stop characters, row identifiers, and symbol characters, which consist of four bars and four spaces each and contain the actual data. This symbology uses error correction symbol characters appended at the end to recover loss of data. Because the virtual wedge translates incoming data into keypad input, the size of the keypad buffer limits the effective length of the label to 128 characters. Longer labels may be truncated. For PDF 417 labels of more than 128 characters, you can develop an application that bypasses the keypad buffer. Action: Tap the PDF 417 parameter, then select an option to change this parameter setting. Tap (+) to access either the Macro PDF Options parameter or the Micro PDF 417 parameter. SNMP OID: 1.3.6.1.4.1.1963.15.3.3.1.1.17.1 Options: 0 Not active 1 Active (default)

700 Series Color Mobile Computer User’s Manual

A-15

Page 265

Control Panel Applets

APPENDIX A

Macro PDF

Macro PDF is used when a long message requires more than one PDF 417 label. Note that this is not available when you use an imager with your 700 Series Computer. Select Buffered to store a multi-label PDF 417 message in the Sabre buffer, thus transmitting the entire message when all labels have been read. " Select Unbuffered for multi-label PDF 417 messages that are too long for the Sabre buffer (memory overflow). Each part of the PDF 417 label is transmitted separately, and the host application must then assemble the message using the macro PDF control header transmitted with each label. Control Header is only present in macro PDF codes and is always transmitted with unbuffered option. Action: Tap (+) to expand the PDF 417 parameter, tap (+) to expand the Macro PDF parameter, select a setting to be changed, then select an option to change this setting. "

SNMP OID: 1.3.6.1.4.1.1963.15.3.3.1.1.22.1 Options: Macro PDF Control header File name Segment count Time stamp Sender Addressee File size Checksum

A-16

0 Unbuffered 1 Buffered (default) 0 Not transmitted (default) 1 Transmitted 0 Not transmitted (default) 1 Transmitted 0 Not transmitted (default) 1 Transmitted 0 Not transmitted (default) 1 Transmitted 0 Not transmitted (default) 1 Transmitted 0 Not transmitted (default) 1 Transmitted 0 Not transmitted (default) 1 Transmitted 0 Not transmitted (default) 1 Transmitted

700 Series Color Mobile Computer User’s Manual

Page 266

Control Panel Applets

APPENDIX A

Micro PDF 417

Micro PDF 417 is a multi-row symbology derived from and closely based on PDF 417 (page A-15). A limited set of symbology sizes is available, together with a fixed level of error correction for each symbology size. Note that this is not available when you use an imager with your 700 Series Computer. Action: Tap (+) to expand the PDF 417 parameter, tap (+) to expand the Micro PDF 417 parameter, select a setting to be changed, then select an option to change this setting. SNMP OID: 1.3.6.1.4.1.1963.15.3.3.1.1.27.1 Options: Decoding Code 128 Emulation

0 1 0 1

Not active (default) Active Not active (default) Active

700 Series Color Mobile Computer User’s Manual

A-17

Page 267

Control Panel Applets

APPENDIX A

Interleaved 2 of 5

Interleaved 2 of 5 (I 2 of 5) is a high--density, self--checking, continuous, numeric symbology used mainly in inventory distribution and the automobile industry. " NOTE:

An Interleaved 2 of 5 bar code label must be at least three characters long for the 700 Series Computer to scan and decode correctly.

Action: Tap (+) to expand the Interleaved 2 of 5 parameter, select the setting to be changed, then tap an option to change this setting or select an option from the drop-down list. SNMP OID: 1.3.6.1.4.1.1963.15.3.3.1.1.23.1 Options: Decoding

0 1 Check digit 0 1 2 3 4 Bar code length 0 1 2 Minimum length 003–254 Fixed length 1 003–254 Fixed length 2 003–254 Fixed length 3 003–254

" NOTE:

A-18

Not active (default) Active Not used (default) Mod 10 transmitted Mod 10 not transmitted French CIP transmitted French CIP not transmitted Any length Minimum length (default) Fixed lengths Minimum length 3–254 (6) Fixed length 3–254 (0) Fixed length 3–254 (0) Fixed length 3–254 (0)

If “1” is selected for Bar code length, then Minimum length is entered. If “2” is selected for Bar code length, then Fixed length 1, Fixed length 2, or Fixed length 3 is entered.

700 Series Color Mobile Computer User’s Manual

Page 268

Control Panel Applets

APPENDIX A

Matrix 2 of 5

Matrix 2 of 5 is a numerical symbology. Note that this is not available when you use an imager with your 700 Series Computer. Action: Tap (+) to expand the Matrix 2 of 5 parameter, select the setting to be changed, then tap an option to change this setting or select an option from the drop-down list. SNMP OID: 1.3.6.1.4.1.1963.15.3.3.1.1.24.1 Options: Decoding

0 1 Bar code length 0 1 Minimum length 001–254

" NOTE:

Not active (default) Active Any length Minimum length (default) Minimum length 1–254 (6)

If “1” is selected for Bar code length, then Minimum length is entered.

700 Series Color Mobile Computer User’s Manual

A-19

Page 269

Control Panel Applets

APPENDIX A

Telepen

Telepen is an alphanumeric, case-sensitive, full ASCII symbology. Note that this is not available when you use an imager with your 700 Series Computer. Action: Tap (+) to expand the Telepen parameter, select the setting to be changed, then tap an option to change this setting. SNMP OID: 1.3.6.1.4.1.1963.15.3.3.1.1.25.1 Options: Decoding Format

A-20

0 Not active (default) 1 Active 0 ASCII (default) 1 Numeric