Appendix A
Control Panel Applets "
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
This appendix contains information about the Data Collection, SNMP, and User Information Control Panel applets that may be on your 700 Series Color Mobile Computer. SNMP and Data Collection settings that can appear under Settings are dependent on what hardware configuration is done for each 700 Series Computer at the time of shipment. These settings will currently only appear if a scanner or an imager option is present. Likewise, other control panel applets that are specifically related to the 802.11b radio module will appear when a 802.11b radio module is installed in a 700 Series Computer. Control panel applets that are specific for Wireless Printing, CDMA/1xRTT, and GSM/GPRS radio modules will only appear when each respective hardware configuration is done on the 700 Series Computer. See Section 4, “Network Support,” for more information about the radio modules or the wireless printing.
Configuration Parameters A configuration parameter changes the way the 700 Series Color (700C) Mobile Computer operates, such as configuring a parameter to have the 700 Series Computer emit a very loud beep in a noisy environment. Use any of the following methods to execute configuration parameters: "
"
"
"
Change Data Collection and SNMP parameters via control panel applets later in this appendix. Access the 700 Series Computer via the Unit Manager through a web browser on your desktop PC via the SRDEVMGMT.CAB file. To use the Unit Manager, install this CAB file from the 700 Color Software Tools CDROM. See the Software Tools Help on the 700C Tools CD for assistance. Send parameters from an SNMP management station. See “SNMP Configuration” starting on page 4-37. Scan EasySet bar codes. You can use the EasySet bar code creation software from Intermec Technologies Corporation to print configuration labels. Scan the labels to change the scanner configuration and data transfer settings.
700 Series Color Mobile Computer User’s Manual
A-1
Page 251
Control Panel Applets
APPENDIX A
Changing a Parameter Setting Menus of available parameters for each group are listed. Use the scroll bars to go through the list. Expand each menu (+) to view its parameter settings. Tap a parameter to select, or expand a parameter (+) to view its subparameters. Note that each parameter or subparameter is shown with its default setting or current setting in (< >) brackets. Tap a parameter or subparameter to select that parameter, then do any of the following to change its setting: Tap Apply to apply any changes. Note that these illustrations are from a Symbologies parameter. " " " "
"
Typing a new value in an entry field. Choosing a new value from the drop-down list. Selecting a different option. The selected option contains a bullet. Tap Defaults, then Apply to restore factory-default settings. Tap Yes when you are prompted to verify this action.
Tap Refresh to discard changes and start again. Tap Yes when you are prompted to verify this action.
About Configuration Parameters You can find the following information about each configuration parameter: Name and Purpose: Describes the parameter and its function. Action: Describes what to do with a parameter once that parameter is selected. SNMP OID: Lists the SNMP OID for the parameter. Syntax or Options: Syntax lists the two-character code for the parameter, if the parameter is configurable by scanning a bar code or by sending parameters through a network. Both Syntax and Options list acceptable values for the parameter. Default settings are noted in italic. A-2
700 Series Color Mobile Computer User’s Manual
Page 252
Control Panel Applets
APPENDIX A
Data Collection Control Panel Applet See “Scanner Control and Data Transfer” in the Intermec Windows CE/Pocket PC Software Developer’s Kit (SDK) User’s Manual shipped with the Software Developer’s Kit (SDK) for information about data collection functions. " NOTE:
Icons are shown to the left.
To access the settings from the 700 Series Computer, tap Start → Settings → the System tab → the Data Collection icon to access its control panel applet.
Use the left and right arrows to scroll through the tabs along the bottom of the control panel applet, then tap a tab to access its menus. These tabs represent four groups of settings or parameters: Symbologies Symbology Options (starting on page A-24) Beeper/LED/Buttons (starting on page A-32) Virtual Wedge (starting on page A-37)
700 Series Color Mobile Computer User’s Manual
A-3
Page 253
Control Panel Applets
APPENDIX A
Symbologies You can change bar code symbology parameter settings in your 700 Series Computer via the Data Collection control panel applet. The following parameters are for bar code symbologies. Additional information about the more common bar code symbologies are in Appendix C, “Bar Code Symbologies.” Note that these parameters are listed in the order of their appearance within this tab. Most of these symbologies apply to both the imager and the laser scanner tools. However, when using an imager, the Macro PDF (page A-16), Micro PDF 417 (page A-17), Matrix 2 of 5 (page A-19), Telepen (page A-20), and Code 11 (page A-21) symbologies are not supported. Likewise, when using a laser scanner, the QR Code (page A-22) and Datamatrix (page A-23) symbologies are not supported. The following table shows which bar code symbologies are supported either by an imager or by a laser scanner.
Bar Code Symbology
Imager
Laser Scanner
Code 39
X
X
Interleaved 2 of 5
X
X
Standard 2 of 5
X
X
Matrix 2 of 5
X
Code 128
X
X
Code 93
X
X
Codabar
X
X
MSI
X
Plessey
X
UPC
X
X
EAN/EAN 128
X
X
Code 11 PDF 417
A-4
X X
X
Micro PDF 417
X
Telepen
X
Datamatrix
X
QR Code
X
700 Series Color Mobile Computer User’s Manual
Page 254
Control Panel Applets
APPENDIX A
Code 39
Code 39 is a discrete, self-checking, variable length symbology. The character set is uppercase A–Z, 0–9, dollar sign ($), period (.), slash (/), percent (%), space ( ), plus (+), and minus (--). Action: Tap (+) to expand the Code 39 parameter, select the setting to be changed, then tap an option to change this setting or select an option from the drop-down list. SNMP OID: 1.3.6.1.4.1.1963.15.3.3.1.1.3.1 Options: Decoding 0 Not active 1 Active (default) Format 0 Standard 43 characters (default) 1 Full ASCII Start/Stop 0 Not transmitted (default) 1 Transmitted Start/Stop characters (Not supported when using an imager): 0 $ (dollar sign) only 1 * (asterisk) only (default) 2 & and * (dollar sign and asterisk) Check digit 0 Not used (default) 1 Mod 43 transmitted 2 Mod 43 not transmitted 3 French CIP transmitted 4 French CIP not transmitted 5 Italian CPI transmitted 6 Italian CPI not transmitted Bar code length 0 Any length (default) 1 Minimum length Minimum length 000–254 Minimum length 1–254 (6) " NOTE:
If “1” is selected for Bar code length, then Minimum length is entered.
700 Series Color Mobile Computer User’s Manual
A-5
Page 255
Control Panel Applets
APPENDIX A
Standard 2 of 5
Standard 2 of 5 is a discrete and self-checking symbology that uses the bars to encode information and the spaces to separate the individual bars. Action: Tap (+) to expand the Standard 2 of 5 parameter, select the setting to be changed, then tap an option to change this setting or select an option from the drop-down list. SNMP OID: 1.3.6.1.4.1.1963.15.3.3.1.1.4.1 Options: Decoding
0 1 Format 0 1 Check digit 0 1 2 Bar code length 0 1 2 Minimum length 001–254 Fixed length 1 000–254 Fixed length 2 000–254 Fixed length 3 000–254
" NOTE:
A-6
Not active (default) Active Identicon, 6 start/stop bars (default) Computer Identics, 4 start/stop Not used (default) Mod 10 transmitted Mod 10 not transmitted Any length Minimum length (default) Fixed lengths Minimum length 1–254 (6) Fixed bar code length 0–254 (0) Fixed bar code length 0–254 (0) Fixed bar code length 0–254 (0)
If “1” is selected for Bar code length, then Minimum length is entered. If “2” is selected for Bar code length, then Fixed length 1, Fixed length 2, or Fixed length 3 is entered.
700 Series Color Mobile Computer User’s Manual
Page 256
Control Panel Applets
APPENDIX A
Codabar
Codabar is a self-checking, discrete symbology. Action: Tap (+) to expand the Codabar parameter, select a setting to be changed, then select an option from the drop-down list to change this setting. SNMP OID: 1.3.6.1.4.1.1963.15.3.3.1.1.5.1 Options: Decoding
0 Not active (default) 1 Active Start/Stop 0 Not transmitted (default) 1 abcd transmitted 2 ABCD transmitted 3 abcd/tn*e transmitted 4 DC1–DC4 transmitted CLSI library system (Not supported when using an imager): 0 Not active (default) 1 Active Check digit 0 Not used (default) 1 Transmitted 2 Not transmitted Bar code length 0 Any length 1 Minimum length (default) 2 Fixed lengths Minimum length 003–254 Minimum length 3–254 (6) Fixed length 1 000–254 Fixed length 0–254 (0) Fixed length 2 000–254 Fixed length 0–254 (0) Fixed length 3 000–254 Fixed length 0–254 (0)
" NOTE:
If “1” is selected for Bar code length, then Minimum length is entered. If “2” is selected for Bar code length, then Fixed length 1, Fixed length 2, or Fixed length 3 is entered.
700 Series Color Mobile Computer User’s Manual
A-7
Page 257
Control Panel Applets
APPENDIX A
UPC/EAN
UPC/EAN are fixed-length, numeric, continuous symbologies that use four element widths. Action: Tap (+) to expand the UPC/EAN parameter, select the setting to be changed, then select an option to change this setting. SNMP OID: 1.3.6.1.4.1.1963.15.3.3.1.1.6.1 Options: UPC A
0 Not active 1 Active (default) UPC E 0 Not active 1 Active (default) EAN 8 0 Not active 1 Active (default) EAN 13 0 Not active 1 Active (default) Add-on digits 0 Not required (default) 1 Required Add-on 2 digits 0 Not active (default) 1 Active Add-on 5 digits (Not supported when using an imager): 0 Not active (default) 1 Active UPC A check digit 0 Not transmitted 1 Transmitted (default) UPC E check digit 0 Not transmitted 1 Transmitted (default) EAN 8 check digit 0 Not transmitted 1 Transmitted (default) EAN 13 check digit 0 Not transmitted 1 Transmitted (default) UPC A number system 0 Not transmitted 1 Transmitted (default) UPC E number system 0 Not transmitted 1 Transmitted (default) UPC A re-encoding 0 UPC A transmitted as EAN 13 (default) 1 UPC A transmitted as UPC A UPC E re-encoding 0 UPC E transmitted as UPC E (default) 1 UPC E transmitted as UPC A EAN 8 re-encoding 0 EAN 8 transmitted as EAN 8 (default) 1 EAN 8 transmitted as EAN 13
A-8
700 Series Color Mobile Computer User’s Manual
Page 258
Control Panel Applets
APPENDIX A
Code 93
Code 93 is a variable length, continuous symbology that uses four element widths. Action: Tap the Code 93 parameter, then select an option to change this parameter setting. Tap (+) to access the Code 93 Lengths parameter. SNMP OID: 1.3.6.1.4.1.1963.15.3.3.1.1.7.1 Options: 0 Not active (default) 1 Active Code 93 Length
Sets the Code 93 bar code length. Action: Tap (+) to expand the Code 93 parameter, then tap (+) to expand the Code 93 Lengths parameter. Tap the setting to be changed, then tap an option to change this setting. SNMP OID: 1.3.6.1.4.1.1963.15.3.3.1.1.19.1 Options (active only if Code 93 is active): Bar code length 0 Any length (default) 1 Minimum length Minimum length 001–254 Minimum length 1–254 (6) " NOTE:
If “1” is selected for Bar code length, then Minimum length is entered.
700 Series Color Mobile Computer User’s Manual
A-9
Page 259
Control Panel Applets
APPENDIX A
Code 128
Code 128 is a variable-length, continuous, high-density, alphanumeric symbology that uses multiple element widths and supports the extended ASCII character set. Action: Tap the Code 128 parameter, then select an option to change this parameter setting. Tap (+) to expand either the Code 128 Options or Code 128 FNC1 character parameters. SNMP OID: 1.3.6.1.4.1.1963.15.3.3.1.1.9.1 Options: 0 Not active (default) 1 Active
A-10
700 Series Color Mobile Computer User’s Manual