Page 21

the Mercury unit and is running Telnet daemon software. At this time, there are only two commands that the telnet prompt recognizes. The first is “help”. This gives a short on-screen instruction about the commands. The other command is “open”. “open” takes one mandatory argument, the IP address of the machine to connect to. It also takes one optional argument, the TCP port number to open the connection on. If the port number is omitted, the default value of 23 is used. There are some configuration options for Telnet, such as forcing a destination IP address and offering a connect prompt. These features are designed for extending dumb terminals into Internet terminals while setting restrictions on the destination of the connection. Please refer to Chapter 6 for more information.

LPD LPD is a printer driver protocol used mainly by UNIX based systems. This is uni-directional protocol: data is received on the network connection and sent out the serial port. Data received on the serial port with this protocol is ignored. Mercury’s configured to use this protocol can buffer up to approximately 32K of data from the network. The document is printed while it is being received on the network. To use this protocol, you must have a UNIX, Windows NT Server, or AS/400 system (or other operating system that supports LPD) with a printer configuration set up to use the Mercury as a remote host. Configuration of the printer varies from one brand to the next; we recommend that you consult documentation that came with your system to properly configure the printer and Mercury for serial settings and flow control. Your operating system must put the data to be printed into a format that the printer will recognize. The Mercury does not perform data translation or formatting. There is no configuration for LPD on the Mercury. When configuring your operating system, use the network hostname or IP address of the Mercury as the remote printer host (UNIX systems should be set up using the Mercury as a remote LPD capable workstation), and any name for the printer. See Application Note #1 for specific instructions on configuring a Windows NT Server platform for LPD printing. 11

Page 22

12

Page 23

CHAPTER 4 - ETHERNET B RIDGE NETWORK TOPOLOGIES Note: This chapter pertains to the Mercury-EN only. If you do not have a MercuryEN, please skip to Chapter 5, Installation.

This chapter describes the bridging capabilities of the Mercury-EN. Mercury Ethernet bridging is a plug-and-play operation. No configuration is needed to set up any of the bridge topologies described below. The only configuration that may be required would be to set different domains and/or channels to prevent interference from other Mercury networks. Other optional configuration, such as designating a Master, may optimize network performance. Please see Chapter 6, Configuration, and Appendix F, Performance Hints, for more details.

BASIC (SINGLE BRIDGE NODE) ACCESS POINT The simplest use of a Mercury-EN as a bridge involves connecting a single Mercury-EN to a device1 or network with a 10Base-T interface. Any other Mercury station that is within radio range and is set to the same domain2 can then be accessed by any device connected to the Mercury-EN.

Network

Mercury

Mercury-EN as Access Point

Figure 4-1 Mercury used as Access Point (and devices on the network)

13

Page 24

When connecting a Mercury-EN 10Base-T port directly to another device (other than a network hub or switch), you will need an “interconnect” cable (sometimes known as a “crossover” or “null-Ethernet” cable). Many network supply dealers can provide you with one. 1

For information about the domain setting, see “Using Domains to Separate Networks”, below, or Chapter 6, Configuration. 2

CELLULAR (MULTIPLE BRIDGE NODES) ACCESS POINTS To use the basic access point topology, it is necessary for all stations to be within radio range of the access point. This is not always possible if the range of the Mercury is insufficient to cover the area required by all stations. The solution is to add additional access points to the wired network. Each access point will cover a certain amount of the required area, allowing stations in range of any of the access points to communicate with the network and each other. Additionally, as stations move around, they may leave the range of one access point and enter another’s range. This process is called roaming (much like roaming of cellular telephones: when one cell site becomes out-of-range, the phone will find another to continue the call with).

Mercury-EN

Mercury roaming

Mercury-EN

Mercury roaming

Figure 4-2 Multiple Mercury’s used as Access Points (with network devices roaming)

14

Page 25

CONNECTING NETWORKS This topology is used in the case where there are two independent wired networks that need to be joined. For example, in Figure 4-3, each building has its own network. Since the two buildings are used by the same company, computer resources between the buildings need to be shared. Using two Mercury-EN to connect the networks eliminates the need to run wire between buildings (potentially down the street from each other) or involve the local phone company.

Mercury-EN

Mercury-EN

Figure 4-3 Two buildings’ networks connected together by Mercury-EN’s

15

Page 26

USING DOMAINS TO SEPARATE NETWORKS Frequently there can more than one network in a given physical location. If so, there needs to be some way of differentiating which network the Mercury is communicating to. This is done with domains. A domain is a number between 0 and 15 that uniquely identifies a wireless network. Only Mercury units with the same domain number will communicate with each other. In Figure 4-4, the Mercury connected to network “A” has a domain number of 5. The Mercury connected to network “B” has a domain number of 3. The mobile Mercury unit that also has a domain number of 5 can only communicate on network “A”. The Mercury on network “B” will not hear any of domain 5’s messages.

Mercury-EN domain 1

Mercury-EN domain 0

Mercury domain 1

Figure 4-4 Two overlapping networks, separated by domain

16

Page 27

COMBINING BRIDGE AND SERIAL TOPOLOGIES The Mercury-EN contains both bridging and serial interface functionality. It is possible to use both features at the same time. Figure 4-5 shows Point-of-Sale (POS) terminals connecting to a server using the 10Base-T connection while simultaneously connecting printers to the serial port. With this configuration, the server can access not only every POS terminal, but also all of the printers (even if the terminals are powered off).

Cash Register 1

Cash Register 2

Ethernet

Serial

Ethernet

Mercury-EN

Serial

Mercury-EN

Mercury-EN Serial

Ethernet

P.O.S Server

Figure 4-5 Point of Sale terminals with external printers

17

Page 28

18

Page 29

CHAPTER 5 - INSTALLATION The Mercury package includes the following items: q

Mercury-RF1 or Mercury-EN unit q

2.4 GHz omnidirectional antenna q

7.5V DC power supply q

RS-232 serial cable

Additional Hardware Requirements: q

Any device with an RS-232 port (Terminal, PC, Instrument, etc.)

Configuration Requirements q

RS-232 Serial Terminal or q

PC with terminal emulation software

INSTALLATION PROCEDURE Follow the steps below to install the Mercury. 1. Attach the antenna using the custom connector on the front of the unit.

Figure 5-1 Attachment of the Mercury antenna

Note: Take care not to over tighten the antenna attached to the connector. This will void the warranty.

2. Attach the RS-232 Cable to the Mercury and then to your RS-232 serial and/or 10Base-T Ethernet device. 3. Plug the power supply into the Mercury power jack and plug the power supply into an AC outlet.

19

Page 30

Antenna

Power Supply (Plug into AC Outlet)

RF1 Radio Module

Figure 5-2 Mercury radio module hardware installation

After you have completed step 3, the LED marked “Power” should light continuously, and the LED marked "Error" should be off. If the error LED lights up, then an error has occurred. See Appendix G to troubleshoot this problem. Antenna

Power

RS-232

Figure 5-3 Front view of Mercury-RF1 radio unit

Power

Antenna

10Base-T

RS-232

Figure 5-4 Front view of Mercury-EN radio unit