Page 11

CHAPTER 1 - INTRODUCTION Thank you for your purchase of the Mercury Serial Wireless Network Interface. The Mercury is a small communications device that replaces RS-232 and/or 10Base-T Ethernet cables with wireless RF (Radio Frequency) technology. In many environments, the Mercury is a “plug-and-play” product. All you need to do is attach a pair of Mercury units to any two devices with three wire asynchronous RS-232 or 10Base-T Ethernet ports and you can transmit and receive data without the use of wires between the devices (See Figure 1-1).

RS-232 Serial Port

RS-232 Serial Port Mercury-RF1

Any RS-232 Device

Mercury-RF1

Any RS-232 Device

Figure 1-1 Mercury units used to replace an RS-232 or Ethernet cable connection

The Mercury uses a frequency hopping, spread spectrum radio for performing wireless communication. It operates within the FCC’s guidelines for spread spectrum systems, and unlike conventional (narrowband) systems, its use does not require an FCC site license. The Mercury supports a wide variety of configurations that can easily be changed to fit your application requirements. All configuration information is saved in non-volatile memory called FLASH. Both the Mercury-RF1 and Mercury-EN support RS-232 serial data rates from 112.5 up to 230,400 bps (bits per second) full duplex, and the Mercury-EN additionally supports 10Mbps Ethernet. Mercury units also offer unit-to-unit configuration, multiple network domains, radio channels, and software subchannels to allow for non-interfering overlapping systems.

1

Page 12

SYSTEM REQUIREMENTS To begin using your Mercury radio device, you will need the following minimum system requirements: q Two or more Mercury radio units, and q Two or more devices (with RS-232 or 10Base-T Ethernet communications ports) that need to communicate with each other.

PACKING LIST In this package, you will find the following components: q One Mercury Serial Wireless Network Interface, q One 2.4 GHz antenna with custom connector, q One 7.5V AC to DC power adaptor, q One RS-232 serial cable, and q One Mercury User’s Guide (the one you are presently reading). If any of these items are missing or damaged, please contact the place of purchase or Nomadic Communications Customer Service.

2

Page 13

CD

RADIO Tx/Rx

ERROR

POWER

MASTER

STATION

SERIAL Tx

SERIAL Rx

CONFIGURE

MERCURY-RF1

Mercury-RF1 or Mercury-EN

2.4 GHz Antenna

Power Adaptor

RS-232 Serial Cable

Figure 1-2 Included components

3

Page 14

4

Page 15

CHAPTER 2 - SERIAL WIRELESS N ETWORK TOPOLOGIES Numerous serial wireless network topologies can be established with the Mercury. Although many exist, all can be simplified into either Point-to-Point or Broadcast topologies. Note: When using a Mercury-EN strictly for Ethernet communication, these topologies do not apply: they describe RS-232 serial communication only. Ethernet communications behave as though all computers are connected to the same network, where data is mixed between broadcast and directed.

POINT-TO-POINT TOPOLOGY In this topology, pairs of devices in the system are configured to communicate with each other exclusively.

RS-232 Serial Port

RS-232 Serial Port Mercury-RF1

Mercury-RF1

Any RS-232 Device

Any RS-232 Device

RS-232 Serial Port

RS-232 Serial Port Mercury-RF1

Mercury-RF1

Any RS-232 Device

Any RS-232 Device

Figure 2-1 Point-to-Point Topology

In Figure 2-1, devices 1 and 2 can communicate with each other, as can devices 3 and 4. Even though all four units may be in range and may all hear each other’s messages, each unit will filter out messages that are not intended for it. In this topology, each pair of units simply replaces an RS-232 cable. This topology is the most commonly used in a wide variety of applications.

5

Page 16

When configured in a Point-to-Point topology, a Mercury unit that receives a message on its serial port will turn the message into a network packet. To this packet the unit adds its own address and the destination unit's address (as stored in the configuration or passed along in the serial message), as well as other critical information. Note: With a Mercury-EN, a network packet can be generated on any computer that has TCP/IP support and is connected to a wired network. The Mercury-EN will process it as though it were a serial data packet (as follows).

Next, it “contends” for time on the airwaves, then transmits the packet over the radio. Finally, the unit waits for an acknowledgment from the destination unit that the packet was received without error. If it does not receive such an acknowledgment and it has not exceeded its maximum retry count, the unit will retransmit the packet. This acknowledge and retry mechanism provides for error-free communication. Any unit that receives packets over its radio will filter them based on the destination address. Only the unit with the correct address will save the packet and send an acknowledgment back to the source unit. Upon receiving a packet the unit also extracts the original message out of the packet and sends it out its serial port. If there was an error in the packet, the unit will ignore it causing the sender to retry. This guarantees the receiving device only receives error-free transmissions.

RS-232 Serial Port

RS-232 Serial Port Mercury-RF1

Mercury-RF1

Any RS-232 Device

Any RS-232 Device

RS-232 Serial Port

RS-232 Serial Port Mercury-RF1

Mercury-RF1

Any RS-232 Device

Any RS-232 Device

Figure 2-2 Broadcast Topology

6

Page 17

BROADCAST TOPOLOGY In this topology a group of Mercury units is configured to have the same specified broadcast address. In Figure 2-2, whenever a message is sent from any unit in this group, all other units in the group that correctly receive the message send it out their serial port. This is also sometimes referred to as a “party-line” or “multi-drop” topology. As in Point-to-Point topology, the device that is transmitting a message over its radio forms a packet, however the packet specifies a broadcast address rather than a specific unit’s port address. Broadcast topology is generally used only when one device needs to send messages to multiple units, something that is usually not possible with conventional RS-232 communications. Broadcast topology is not as common as Point to Point topology, because most existing software that use RS-232 communication are designed for communication with a single device on the other end of the serial line. Unlike with Point-to-Point topology, after the Mercury sends the packet it does not wait for an acknowledgment. Broadcast mode is an unacknowledged service for two reasons: 1) because the broadcasting unit doesn’t know who is going to be receiving the data, and 2) even if it did know, it can be extremely inefficient to have every unit acknowledge a message once the packet is received. Since broadcasts are unacknowledged, a unit cannot retry transmissions while configured for this topology. Any Mercury unit that correctly receives the packet compares the packet's broadcast address to the unit's own broadcast address. If the two addresses match, the unit will extract the message and send it out its serial port. This guarantees that the user's devices only receives error-free transmissions. Note: Since broadcasting is an unacknowledged service, if a message was lost or damaged, the message will not get through. Therefore, the user's devices should contain software to perform message retransmissions should this be necessary. Often devices that can use wired networks already contain such software. Note: The TCP/IP network protocol is not capable of broadcast operation, due to the connection-based design of the protocol. If broadcast operation is desired, use of the RMP protocol is necessary.

7

Page 18

HYBRID T OPOLOGIES Although Point-to-Point and Broadcast topologies are the most common, the Mercury allows for a great variety of hybrid topologies. A common type of hybrid topology is the client-server topology. In this layout, one Mercury is connected to a server and multiple Mercury’s are connected to clients. The server Mercury is configured for Broadcast (allowing communication to all of the clients), but each of the client Mercuries are configured for Point-to-Point (allowing communication only to the server: the clients don’t hear each other’s messages).

8

Page 19

CHAPTER 3 - SERIAL PORT PROTOCOLS The Mercury’s serial interface can interpret and process serial data in one of five ways: passthrough, passthrough2, ProxLink, Telnet, and LPD. The format of the information presented to the unit’s serial port is different depending on which of these five modes is selected. Note: Not all protocols are available on all units. Procotols that require the use of the TCP/IP network protocol (passthrough with TCP, passthrough2, Telnet, and LPD) require that the TCP/IP option be purchased separately on Mercury-RF1 units. This restriction does not apply to Mercury-EN units.

PASSTHROUGH For applications where an RS-232 cable is to be replaced by a pair of Mercury units without changes to the existing network protocol, or when Mercury units are being used to form a broadcast or clientserver topology, the passthrough protocol should be used. With the passthrough protocol, the unit accepts a stream of serial data at its serial (RS-232) port and passes it over the radio network (via either the RMP or TCP/IP network protocols) to one or more receiving units. The data arrives at the receiving unit(s) which then transmits the data out of its serial port(s). With this protocol, data is sent transparently to the receiving unit, as though the units were directly connected via serial cables. The data is not filtered or interpreted by either of the Mercury units. This protocol is most useful if the Mercury is to be used as a drop-in replacement for serial cable; that is, that the device the Mercury is connected to does not know that its data is being transmitted by radio. The passthrough protocol has several configuration options, some designed to optimize data throughput. These options tell the Mercury when to transmit the data. They are necessary because there is communication overhead in transmitting the data over the radio; sending one hundred (100) bytes of data takes roughly half the amount of time as it takes to send one thousand (1000) bytes. Through configuration, the user can help the Mercury decide how to minimize this overhead. Configuration details are covered in Chapter 6.

9

Page 20

PASSTHROUGH2 The passthrough2 protocol, like the passthrough protocol, makes no changes to the serial data stream as it is transmitted or received. It differs in the fact that it creates two independent network connections for transmitted and received data, allowing transmitted data to be sent to a different location than received data originates from. The passthrough2 protocol is only available using the TCP/IP network protocol (it isn’t needed for RMP due to the fact that RMP does not restrict the source and destination locations of data as the TCP/IP protocol does). Normally with the passthrough protocol, one bidirectional TCP/IP connection is made to a remote computer (or another Mercury). Since there is only one connection, data must travel in both directions on it. In order for the destination of data to differ from the source of data, two connections must be made. The passthrough2 protocol allows this to happen. Please see Chapter 6 for more details on configuration of this protocol.

PROXLINK The ProxLink protocol is designed to allow better control of the Mercury’s data stream by wrapping the data to be sent or received in a package that designates the source or desired destination of the data. This allows the user to write application software that needs to communicate to multiple remote sites simultaneously without having to broadcast all data to all locations. This protocol also allows control over hardware settings of the Mercury such as baud rate, radio domain and channel, low power states, etc. Details on the format of this procotol are available in Chapter 7.

TELNET Telnet is a protocol that uses the TCP/IP networking protocol. Originally designed for UNIX-based operating systems, it allows a person on one computer to run applications or otherwise control a remote computer. The Mercury provides a “telnet prompt” much like that used on UNIX systems. From this prompt, a user can open connections to any computer that is connected to the same network as

10