Page 101

JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A

Different Ways to Configure the JANUS 2050 You can configure the JANUS 2050 in several ways: Using the Configuration Application The configuration application program is run on the JANUS 2050. The menus and dialog boxes list all of the configuration options available on the JANUS 2050 and indicate what parameters are currently enabled. You can create various configuration files for different situations and load the necessary configuration file for each application. Editing a Configuration File Using the Host Computer The configuration application uses the configuration files to display the current configuration. You can edit a configuration file without using the configuration application program by uploading the file to the host computer. On the host computer, you can edit the file or create new configuration files. When you download the file to the JANUS 2050, you make the file the active configuration by loading it in the configuration application program and making it the online configuration. When the JANUS 2050 boots, the configuration file (JANUS.INI) is used to set the initial configuration. If the configuration file does not exist, the JANUS 2050 is set to the default configuration. Scanning Bar Code Labels You can scan bar code labels to quickly change the JANUS 2050’s configuration. You can scan the bar code labels listed in this manual if you just want to change one or two configuration settings, or you can create your own bar code labels to configure a large number of JANUS 2050s. Using IRL Z Commands Z commands are included in IRL programs to modify the JANUS 2050’s configuration for that specific program. You can automatically configure the JANUS 2050 each time an IRL program is executed by including Z commands in the program statements. This feature is useful if the JANUS 2050 needs to be configured a certain way when running the IRL program. Through a User Application You can also configure the JANUS 2050 by sending a configuration command string down from a host computer when the JANUS 2050 is running a user application. This method is similar to configuring from an IRL program. The JANUS 2050 must be running a user application that accepts the configuration commands. You can configure the JANUS 2050 by sending configuration command strings when using the IRL Desktop, or an application that specifically uses the Reader Services input manager. You cannot configure the JANUS 2050 by sending configuration command strings when the JANUS 2050 is at the DOS prompt. Note: The configuration commands are listed alphabetically in Chapter 10, “Configuration Commands.” This reference includes a description of the purpose, options, and command syntax for each command.

4-6

Page 102

nuggJVMUConfiguring the JANUS 2050

4

Using the Configuration Application The configuration application is a menu-driven application that lets you configure the JANUS 2050 and view system information. To open the configuration application from the DOS prompt, type: ic

Then press e . Or, scan the following bar code:

*IC* *IC*

In the menu bar, there are four drop-down menus: Configuration File Sym Com

File Select the File menu to load or save configuration files, or return to the default configuration. You can also display software versions, equipment information, and available memory. You quit the configuration application by selecting Exit from this menu.

Op

Load... Load Default Save Save As... About Exit

?

2050U.060

Sym Select the Sym menu to enable or disable decoding of bar code symbologies. Some of the symbologies also allow you to determine the check digit and label length.

Com Select the Com menu to set the communications protocol for each of the JANUS 2050’s COM ports and to define the parameters for each selected protocol. Op Select the Op menu to change the operating parameters for the JANUS 2050. You can modify parameters and options for turning the JANUS 2050 on and off, data manipulation, JANUS 2050 display, beeper control, keypad, and scanner operation. Note: When you are configuring the JANUS 2050 using the drop-down menus, press l for online help.

4-7

Page 103

JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A

Configuration File Sym Com

To select a menu in the menu bar, press g or i to move the highlight to the desired menu. To view the drop-down menu, press e or j .

Op

Load... Load Default Save Save As... About Exit

?

2050U.060

Configuration File Sym Com

Op

Amble... Beeper... Reader Cmds Display... Viewport... Keypad... Scanner... IRL... Power Mgmt... Key Codes ?

2050U.062

The Sym, Com, and Op drop-down menus list the various configuration selections. An asterisk (*) on the Sym or Com protocol drop-down menu indicates that the symbology or protocol is active. When a drop-down menu is displayed, select a command by pressing h or j to move the highlight to the desired command, and then press e to choose the command. Press d to exit a menu.

The dialog boxes list the options for the configuration parameters. The field below the option will be either a toggle or an entry field. When a dialog box displays, press h or j or Tab/BackTab to move the highlight to the desired field. In a highlighted field, either enter a value or press g or i to view the options for that field. A few dialog boxes contain check boxes. Check boxes are used when more than one option can be selected at a time. Press s to mark or clear check boxes.

4-8

•

Pressing e is the same as choosing OK. It exits the dialog box and saves the changes.

•

Pressing d is the same as choosing Cancel in single screen configurations only. It exits the dialog box without saving the changes.

•

When you set parameters on multiple screens, such as communications protocol, use the Next and Prev commands to move between the screens.

Page 104

nuggJVMUConfiguring the JANUS 2050

Configuration File Sym Com

4

To exit the configuration application, select Exit in the File drop-down menu and press e .

Op

Load... Load Default Save Save As... About Exit

Instead of pressing keys on the keypad, you can scan the bar code labels listed in Appendix A to move the cursor through the configuration menus.

?

2050U.060

Entering ASCII Control Characters There are two types of configuration parameters that you can use to enter ASCII control characters for the settings. They are communications protocol characters, and operation preambles and postambles.

Communications Protocol Characters Some communications protocols require you to set the protocol character to an ASCII control character. To enter an ASCII control character for one of the protocol characters in the dialog box, such as EOR and EOM, press c followed by a letter, number, or symbol key. For example, to enter the ASCII character STX, press c B and the word <STX> appears in the protocol character field. The ASCII control characters and their corresponding keys are listed in Appendix A. If you want to disable the protocol character, highlight the space next to the protocol character you want to disable and press b .

Operation Preambles and Postambles You can include ASCII control characters in the preamble or postamble fields in the dialog box using an escape sequence. For example, to set the postamble to Carriage Return Line Feed, enter: \r\n

The escape sequences for the ASCII control characters are listed in Appendix A. If there is not an abbreviation for the ASCII control character, enter the twodigit hexadecimal number (\xnn where nn is the hex value) for the ASCII control character. The hex numbers are listed in the full ASCII chart in Appendix A. For example, to enter the value for ETX, enter: \x03

4-9

Page 105

JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A If you enter the hex number for ASCII characters above 7F hex (128 decimal), the JANUS 2050 displays the extended ASCII character instead of its numerical value in the dialog box.

Using Multiple Configuration Files When you change the JANUS 2050’s configuration, you can save the configuration under a filename with the extension .INI. It is similar to a word processor where you can load, edit, and save the files as many times as you want. For example, if you change the JANUS 2050 configuration and exit the configuration application, the JANUS 2050 asks if you want to update the online configuration before exiting. If you press e , the changes you made in the application are now used by the JANUS 2050. Configuration File Sym Com

You can then go back into the configuration application and reconfigure the JANUS 2050. Instead of exiting the configuration application, choose the command Save As from the File drop-down menu and enter a filename, such as EXAMPLE.INI.

Op

Load... Load Default Save Save As... About Exit

?

2050U.063

When exiting the configuration application, the JANUS 2050 asks if you want to update the online configuration. If you choose yes, the configuration settings in the EXAMPLE.INI file apply to the JANUS 2050 upon exiting the configuration application. If you choose no, the configuration settings before the changes you just made remain active. The EXAMPLE.INI file has already been saved and can be made active at any time. If you do not make EXAMPLE.INI the active configuration, you can return at any time to the configuration application and choose Load from the File dropdown menu. Select EXAMPLE.INI from the list of filenames and press e . EXAMPLE.INI is loaded into the configuration application. When exiting the configuration, the JANUS 2050 asks if you want to update the online configuration. If you choose yes, EXAMPLE.INI is now the active configuration.

4-10

Page 106

nuggJVMUConfiguring the JANUS 2050

4

Configuring the JANUS 2050 From the DOS Prompt You can create, load, and save configuration files by using switches with the ic command at the DOS prompt. The switches are: Command

Description ic /l {path\filename}

Loads a configuration file.

ic /s {path\filename}

Saves a configuration file.

ic /d

Loads the factory default configuration.

where path is the drive and directory that contains the file, and filename is the name of the configuration file. These commands do not execute the menu-driven configuration application (IC.EXE). The menu-driven application executes when you type the ic command without any switches or parameters.

Loading a New Configuration File You can make any configuration file active by typing this command at the DOS prompt: ic /l {path\filename}

When you type this command, the JANUS 2050 displays this message: Loading Reader Configuration from {path\filename}

The configuration file specified in the message is now active.

Automatically Loading a Configuration File You can make any configuration file load automatically whenever you boot the JANUS 2050 by adding this command to the AUTOEXEC.BAT file: ic /l {path\filename}

The JANUS 2050 will automatically load the configuration file whenever the AUTOEXEC.BAT file executes.

4-11

Page 107

JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A

Saving a New Configuration File If you modified your configuration or loaded a new file, you can save the current configuration under a new filename by typing this command at the DOS prompt: ic /s {path\filename}

When you type this command, the JANUS 2050 checks to see if the filename already exists. If it does, this prompt appears: Overwrite (Yes/No)? N

Choose your response: •

Press N or e if you do not want to overwrite the file. The changes stay in effect only until the JANUS 2050 is powered off or rebooted.

•

Press Y to overwrite the contents of the file with your changes.

As the JANUS 2050 saves the changes, it displays this message: Saving Reader Configuration to {path\filename}

The JANUS 2050’s configuration is now saved to the specified file.

Loading the Factory Default Configuration You can load the factory default configuration without rebooting by typing this command at the DOS prompt: ic /d

4-12

Page 108

nuggJVMUConfiguring the JANUS 2050

4

Editing a Configuration File Using the Host Computer If you want to edit configuration files on the host computer, you can upload configuration files and edit the file using any standard text editor. All configuration files have the extension *.INI. When the JANUS 2050 performs a reboot, if JANUS.INI is present, the JANUS 2050 loads the configuration settings from JANUS.INI. Otherwise, it loads the default configuration. A configuration file contains lines similar to the command line column: Command Line

Definition

AD""

Preamble disabled

AE"\x0D"

Postamble set to CR

BD"00050L"BD"00050H"

Beep duration set to 50 ms for low and high beeps

BF"01200L"BF"02400H"

Beep frequency set to 1200 Hz for low beeps and 2400 Hz for high beeps

BV"1"

Beep volume set to quiet

CA"99"

Interleaved 2 of 5 set to variable length with a check digit

The configuration commands must be in uppercase for the JANUS 2050 to recognize the commands. You should enclose the command options in quotes (for example, BV"1") when you are editing the configuration file. Quotes are used to designate the end of a configuration command. Use double quotes to enter a quote in the command line. For example, AD""4 is interpreted as AD"4. Appendix A contains a configuration command syntax cross-reference. To determine the definition of each command line in your configuration file and learn the available options, see Chapter 10, “Configuration Commands.” Once you have made the changes to a configuration file and downloaded it to the JANUS 2050, you can make the configuration file active by following these steps. To activate the configuration file 1. Type ic to start the configuration application program. 2. Select File and then Load. 3. Enter the name of the modified configuration file including the path and press e . 4. Select File, then Exit, and press e to update the online configuration.

4-13

Page 109

JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A The edited configuration file is now active. If there are any errors in the configuration file, the JANUS 2050 generates an error file called JANUS.ERR. This file lists the line numbers with the incorrect syntax and the reason for the error. The command SET IM_ERRPATH=E:\ listed in the AUTOEXEC.BAT specifies that the error file is written to drive E. To view the error file, change to drive E on the JANUS 2050 and enter the following: type janus.err

If your edited configuration file contains errors, use the configuration application to enter the correct option for the configuration parameter that caused the error.

Configuring With Bar Code Labels You can configure the JANUS 2050 by scanning bar code labels listed in this manual, or by creating your own bar code labels. Creating your own bar code labels is useful when configuring a number of JANUS 2050s. You can create bar code labels that contain more than one configuration command. For example, configuring a JANUS 2050 for User-Defined protocol (PS0) on COM1 (IS1), with a baud rate of 2400 (IA4), even parity (IB1), 8 data bits (II8), and 2 stop bits (IC2) can be done with three bar codes. Each bar code starts with $+ (the change configuration command), followed by the syntax and option for each parameter. Configure for COM1, Configure User-Defined Protocol

*$+IS1PS0* *$+IS1PS0*

2400 Baud, Even Parity, 8 Data Bits, and 2 Stop Bits

*$+IA4IB1II8IC2* *$+IA4IB1II8IC2*

Activate User-Defined Protocol

*$+PA0* *$+PA0*

Note: You must enclose parameter options with quotation marks if those options conflict with reader configuration commands. For example, you may want to set the postamble to the letters “BV”, which happen to be the beep volume command. You can enter this command by using $+AE”BV”. If you leave out the quotation marks ($+ADBV), the JANUS 2050 mistakes the command as setting the preamble (AD) to no characters, and changing the beep volume command (BV).

4-14

Page 110

nuggJVMUConfiguring the JANUS 2050

4

Configuring Using IRL Z Commands You can automatically configure the JANUS 2050 each time an IRL program is executed by including Z commands in the program statements. These configuration changes are saved in the online configuration file. For example, if you want to change the display mode from buffered to transparent, you would insert the following Z command in your IRL program: Z"$+DM1"

When the IRL program reaches this command statement, it would configure the JANUS 2050 and continue executing the program.

Configuring Through a User Application When creating an application to run on the JANUS 2050, you can program the JANUS 2050 to accept configuration command strings from the host computer using Reader Services. These configuration changes are saved in the online configuration file. For example, to configure the JANUS 2050 to decode Code 93, the computer would send the following command string to a user application: $+CF1

The user application must be designed to accept command syntax from the host. The JANUS 2050 cannot accept command strings when it is at the DOS prompt. For information on using Reader Services, refer to the JANUS PSK reference manual set.

4-15