Page 91

JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) CD39nugg

7. Create the drive image by typing this command at the host computer’s DOS prompt: makedisk /s=c:\drived /o=newdrvd.img /d=d

An image file, NEWDRVD.IMG, is created in the working directory of the host computer’s drive C. Note: Do not create the image file in the directory where the source files reside. 8. Copy the image file from the host computer to the PC card and then insert the PC card into the JANUS PC card drive (drive G). Note: It is recommended that you provide an external power supply for the JANUS device before you execute PutDisk. 9. At the DOS prompt on the JANUS device, type this command to load the new image file onto drive D. putdisk /i=g:\newdrvd.img /d=d

Using Reader Services Reader Services are programs that decode bar codes, process data input and output (I/O), configure the reader, and handle all power management for the reader. AUTOEXEC.BAT loads Reader Services when you boot the reader. You do not interact directly with Reader Services because they operate as part of the reader’s system software. You can create applications that use Reader Services. For help, see your JANUS PSK reference manual. Reader Services include these programs: Communications Utilities Communications Utilities are transmit and receive functions that you can call with PSK functions or software interrupts. Communications Utilities let the reader transmit and receive buffers or bytes of data regardless of the communications protocol that you use. Configuration Manager Configuration Manager maintains the reader’s current configuration file (such as JANUS.INI), ensures that the reader operates according to that configuration, and lets you change the reader’s configuration file. Configuration Manager is a terminate and stay resident program (TSR) that loads into the reader’s memory during a warm or cold boot. For help, see “Unloading and Loading Configuration Manager TSR” later in this chapter. Input Manager Using software interrupts and library functions, your reader applications can use Input Manager as an interface for all data I/O from the reader’s COM ports, wand, scanner, and keypad. Input Manager also handles all power management during data I/O. For help with software interrupts and library functions, see your JANUS PSK reference manual.

3-28

Page 92

nuggJVMUUsing the JANUS 2050 Software

3

You can use Input Manager to customize how the reader handles data from the keypad, wand, or scanner. The reader can display all input, beep when labels are scanned, and parse reader commands. For example, when you scan a bar code label, Input Manager can identify the symbology and if the label includes reader commands. Virtual Wedge The Virtual Wedge decodes and manages bar code input, making the reader functionally equivalent to a wedge reader connected to a PC. This program facilitates rapid porting of PC applications to the reader. When you scan a bar code label, the Virtual Wedge inserts the data into the keyboard buffer as if it had been typed. The Virtual Wedge sends configuration commands to Configuration Manager. The Virtual Wedge also recognizes and implements reader commands. Direct Hardware Wedge The Direct Hardware Wedge is a new feature of JANUS 4.0 software that allows bar code data to emulate keystrokes on the keypad. For more information on the Virtual Wedge and Direct Hardware Wedge, see “Understanding the Bar Code Wedge,” in the following section.

Understanding the Bar Code Wedge The Bar Code Wedge is a Reader Services feature that enables your JANUS device to decode bar codes, making it functionally equivalent to a wedge reader connected to a PC. Prior to JANUS 4.0 software, the only wedge option was the Virtual Wedge. With the 4.0 software release, the Reader Services wedge feature has a second option, the Direct Hardware Wedge. When you scan a bar code with the Virtual Wedge Option enabled, data is inserted directly into the keyboard buffer as if it had been typed. The Direct Hardware Wedge provides hardware level PC compatibility and processes the scanned data directly as individual keystrokes. The Direct Hardware Wedge provides bar code data to applications that directly access the hardware, it is the option to select when working with applications (for example, Attachmate, FTP, Zstem for DOS, PC-TCP for DOS, and others) that require keystroke interrupts to occur when data is received. The Virtual Wedge option, which is up to 10 times faster than going through the PC hardware, is the option you should select when you need maximum performance. If you have developed advanced applications for your JANUS device, you need to customize how the reader and application handle data from the keypad, wand, or scanner. Refer to the JANUS Programmer’s Software Kit and reference manuals for instructions. The Virtual Wedge is the default configuration. You can enable the Direct Hardware Wedge by using the KWC.COM program. For more information, see “Using the Wedge Configuration Program,” later in this chapter.

3-29

Page 93

JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) CD39nugg

Enabling Direct Hardware Wedge Functions When you enable the Direct Hardware Wedge function, you disable the portion of the Virtual Wedge that inserts data directly into the keyboard buffer. With the Direct Hardware Wedge function enabled, data is inserted into the hardware to be processed as actual keystrokes. The processing of Reader Services commands and configuration bar codes is not affected by the wedge option you select. Intermec recommends that you enable the Direct Hardware Wedge if you experience any of the following problems using off-the-shelf PC software on your 4MB JANUS device. •

You scan a bar code and get a “read beep,” but the data isn’t received by your application.

•

You scan a bar code and characters are dropped.

•

Your application uses bar codes to manipulate screen functions and the screen doesn’t respond correctly.

Note: If you attempt to run the wedge configuration program on a JANUS device running version 3.0 or earlier software, the Direct Hardware Wedge feature will not be available. The Direct Hardware Wedge feature requires a software modification and a new KSCPU chip.

Using the Wedge Configuration Program

@

You can use the wedge configuration program (KWC.COM) to set wedge options on your 4MB JANUS device. To start KWC.COM, type this command . at the DOS prompt and press kwc

Or, scan this bar code.

*KWC* *KWC*

The main menu appears, displaying five configuration options.

C:\ >KWC Keyboard Control Copyright 1996 Intermec Corp. Version 1.00 Usage: KWC 0 - KW off 1 - KW on 2 - KW on 3 - KW off 4 - status x , XKBD , XKBD , XKBD , XKBD only on on off off

C:\ > 20X0A.004

3-30

Page 94

nuggJVMUUsing the JANUS 2050 Software

Option 0 Option 0 is the default configuration. Select Option 0 to enable the Virtual Wedge and the expanded keyboard. To select this option, type the following command at the DOS prompt and press .

@

3

C:\ >KWC 0 Keyboard Control Copyright 1996 Intermec Corp. Version 1.00 KW Disabled XKB Enabled kwc 0

C:\ >

Or, scan this bar code.

*KWC 0*

20X0A.005

*KWC 0*

Note: The AUTOEXEC.BAT on your 4MB JANUS device is set to Option 0 (Virtual Wedge enabled/extended keyboard enabled). To permanently change this option, you will need to modify your AUTOEXEC.BAT file and load a new image to drive C. Option 1 Select Option 1 to enable the Direct Hardware Wedge and the expanded keyboard. To select this option, type the following command at the DOS prompt and press .

C:\ >KWC 1 Keyboard Control Copyright 1996 Intermec Corp. Version 1.00 kwc 1

KW Enabled XKB Enabled

Or, scan this bar code.

*KWC 1*

@

C:\ >

20X0A.006

*KWC 1*

Note: The following two options disable the expanded keyboard buffer. The expanded keyboard buffer allows the JANUS device to consistently process bar codes that are longer than 15 characters. Do not disable the expanded keyboard unless your application continues to experience compatibility problems.

3-31

Page 95

JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) CD39nugg

Option 2 Select Option 2 to enable the Direct Hardware Wedge and disable the expanded keyboard. To select this option, type the following command at the DOS prompt and press .

C:\ >KWC 2 Keyboard Control Copyright 1996 Intermec Corp. Version 1.00 kwc 2

KW Enabled XKB Disabled

@

Or, scan this bar code.

C:\ >

*KWC 2*

20X0A.007

*KWC 2*

Option 3 Select Option 3 to disable the Virtual Wedge and the expanded keyboard. To select this option, type the following command at the DOS prompt and press .

C:\ >KWC 3 Keyboard Control Copyright 1996 Intermec Corp. Version 1.00 kwc 3

KW Disabled XKB Disabled

@

Or, scan this bar code.

*KWC 3*

C:\ >

20X0A.008

*KWC 3*

Option 4 Select Option 4 to display the current wedge configuration status. To select this option, type the following command at the DOS prompt and press .

@ kwc 4 Or, scan this bar code.

*KWC 4* *KWC 4*

3-32

Page 96

4 Configuring the JANUS 2050

Page 97

This page is a scan with no text; see it in the PDF.

Page 98

nuggJVMUConfiguring the JANUS 2050

4

This chapter discusses the various ways you can configure the JANUS 2050, lists all the configuration options, and identifies the default setting for each option.

Overview of Configuration Parameters Configuration options let you fine-tune the JANUS 2050 to work efficiently in your system. •

You determine what bar code symbologies the JANUS 2050 should decode.

•

You tell the JANUS 2050 what communication standards to use when talking to a host computer or other devices.

•

You also modify the JANUS 2050 to work efficiently in your particular work environment.

Configuring for Bar Code Symbologies The bar code symbologies configuration parameters include all the types of bar codes the JANUS 2050 can decode. You should enable the bar code symbologies that you are going to scan. For some symbologies, you also need to tell the JANUS 2050 what type of check digit the bar code will include or the length of the bar code label. The JANUS 2050 reads and decodes the following symbologies: •

Codabar

•

Code 16K

•

Code 11

•

Interleaved 2 of 5

•

Code 39

•

MSI

•

Code 49

•

Plessey

•

Code 93

•

Code 2 of 5

•

Code 128

•

UPC/EAN

The JANUS 2050 automatically recognizes and decodes as many of these symbologies as needed by your application. This feature is called autodiscrimination. Note: The fewer symbologies you enable the JANUS 2050 to decode, the faster it can decode a bar code label.

4-3

Page 99

JANUS 2050 Vehicle-Mount Computer User’s Manual (4MB) 39 nugget A When you enable multiple symbologies, the JANUS 2050 may, on rare occasions, decode bar code labels in a symbology other than the label’s actual symbology. Row clicks may also occur, indicating that the label was decoded as a row in a two-dimensional symbology. To avoid this problem, only enable the JANUS 2050 to decode the bar code symbologies that you are using. If the problem does occur, scan the label again. MSI and Plessey configurations are disabled by default.

Defining Communications Parameters The communications configuration parameters include the communications ports, protocols, and the parameters that define the individual protocols. The communications port designates the port for which you are configuring the protocol. The communications protocol and its parameters determine how the JANUS 2050 talks to the device to which it is connected. You can configure more than one protocol for a port. However, only one protocol at a time can be active for each port. The JANUS 2050 can communicate using the following protocols and parameters. Each protocol has certain parameters that can be set for that protocol.

Communications Parameters

4-4

Protocol

Parameter

User-Defined

• • • • • • • •

Baud rate, parity, data, and stop bits Flow control, LRC Intercharacter, turnaround, and timeout delay Transmit abort timeout SOM, EOM POL, SEL, RES, REQ, AFF, NEG EOF, EOR, and number of records per block IRL PAK, IRL BAK, IRL SOP, IRL EOP, IRL RUN, IRL END, and IRL PSS

User-Defined Multi-Drop

• • • • • • • •

Baud rate, parity, data, and stop bits Flow control, LRC Intercharacter, turnaround, and timeout delay Transmit abort timeout SOM, EOM POL, SEL, RES, REQ, AFF, NEG EOF, EOR, and number of records per block IRL PAK, IRL BAK, IRL SOP, IRL EOP, IRL RUN, IRL END, and IRL PSS

Page 100

nuggJVMUConfiguring the JANUS 2050

4

Communications Parameters (continued) Protocol

Parameter

Point-to-Point

• • • •

Baud rate, parity, data, and stop bits Flow control Intercharacter, turnaround, and timeout delay Transmit abort timeout

Polling Mode D

• • •

Baud rate Flow control Transmit abort timeout

Multi-Drop

• • •

Baud rate, parity, data bits Transmit abort timeout Address, Multi-Drop

PC Standard

•

Baud rate, parity, data, and stop bits

Modifying Operations Parameters The operations configuration parameters include all areas that assist you in using the JANUS 2050. The JANUS 2050 can be configured to: •

Modify data from bar code labels using preambles, postambles, and the key code lookup table.

•

Disable specified commands.

•

Modify the beeper duration, frequency, and volume.

•

Modify the display mode and setup.

•

Modify the keypad clicker, c key functions, and numeric keypad.

•

Modify scanner operation with scanner data buffering, modes, redundancy, timeout, trigger, and decode security.