Page 521
NF
BC Software Utility Reference
D
Using LOADXIMG LOADXIMG loads the default image file, NEWDRV_C\DRIVEC.IMG, onto the reader’s drive C. LOADXIMG overwrites all files currently on drive C. You must have created the image file already with the MAKENEW, MAKE_USA, LOADADD, LOADNEW, LOADLANG, or LOAD_USA commands. LOADXIMG is useful when you are loading an image file onto multiple JANUS readers. Here is the syntax for LOADXIMG: loadximg
Using MAKE_USA MAKE_USA creates an image file that contains only the three startup files in C_FILES\COMMON. No other files are included in the image file. You must use LOADXIMG or LOADIMG to load the image file onto the reader’s drive C. The Make commands offer the advantage of allowing you to create an image file on the host that you can use to update multiple readers. Here is the syntax for MAKE_USA: make_usa
Note: If you installed Auto-Loader for a DOS NLS country, the MAKE_USA batch file is not installed.
Using MAKELANG MAKELANG creates an image file that contains only the three startup files in C_FILES\COMMON. No other files are included in the image file. The MAKELANG command also edits AUTOEXEC.BAT and CONFIG.SYS to support the DOS NLS language you specified when you installed Auto-Loader. For help, see Chapter 8, “Preparing the Reader for International Use.” You must use LOADXIMG or LOADIMG to load the image file onto the reader’s drive C. The Make commands offer the advantage of allowing you to create an image file on the host that you can use to update multiple readers. Here is the syntax for MAKELANG: makelang
Note: If you installed Auto-Loader for a DOS NLS country, the MAKELANG batch file is installed instead of the MAKE_USA batch file.
D-15
Page 522
JANUS 2020 Hand-Held Computer User’s Manual NF BC
Using MAKENEW MAKENEW creates an image file that contains any files you include in the command line. If you do not specify startup files in the command line, MAKENEW adds the three default startup files in C_FILES\COMMON to the image file. If you specified a DOS NLS country when you installed Auto-Loader on the host computer, MAKENEW appends commands to the AUTOEXEC.BAT and CONFIG.SYS files to support that DOS NLS language. You must use LOADXIMG or LOADIMG to load the image file onto the reader’s drive C. The Make commands offer the advantage of allowing you to create an image file on the host that you can use to update multiple readers. Here is the syntax for MAKENEW: makenew path\filename [path\filename path\filename...] where: path is the drive and directory of the file to include in the image file.
filename is the name of the file to include in the image file.
You can specify more than one file or use path\*.* to load all the files from a directory.
D-16
Page 523
Gi
/ ossa ry
Page 524
Page 525
Glossary
G
Accumulate mode Operating mode in which the reader stores scanned information in the reader’s data buffer until the reader receives a enter command. acknowledgment delay Specifies the maximum amount of time that may elapse before the controller determines that a device did not receive the message. AFF Affirmative Acknowledge character. This character enables or disables the handshake event that is an affirmative acknowledge to a message. alphanumeric keypad The alphanumeric keypad is an all-purpose keypad with 52 keys. Although the keypad is smaller than a regular PC keyboard, you use special keys on the reader’s keypad and press key combinations to access all 102 keys that are available on a PC keyboard. The alphanumeric keypad is available in English, French, German, Italian, and Spanish. application break bit A flag in the reader that an application checks when you turn on the reader. If the bit is not set to 1, the application will resume running. If the bit is set to 1, the application will not resume. You press the application break sequence to set the application break bit. application break sequence A series of keys you press to stop an application from resuming after you turn the reader off and then on again. Usually you use these keys when an application is locked up and you do not want to cold boot the reader to clear the memory. Application companion disk One of the disks that Intermec ships with your JANUS reader. This disk contains applications such as Communications Manager and IRLXDESK.EXE. This disk also contains PC card drivers and utilities that control the reader’s operation, prepare the reader to use the different types of PC cards, customize the reader to use the PC card software, and provide you with helpful tools. ASCII American Standard Code for Information Interchange. A standard 7-bit code almost always transmitted with a parity bit for a total of 8 bits per character.
G-3
Page 526
JANUS 2020 Hand-Held Computer User’s Manual
ASCII control character One of the first 32 characters (0 through 31 in decimal representation) in the ASCII character set. Each of these characters has a standard control function, such as backspace or carriage return. ATA flash PC card A type of memory PC card that provides additional disk storage space, not more executable convention memory, on a JANUS reader. audio signals The reader has a beeper and a clicker that produce audio signals that indicate reader status. You can change the beep volume and enable or disable the keypad clicker with configuration commands. Auto-Loader A DOS utility used to change the contents of drive C. You can also use it to configure the reader to operate in any language supported by DOS NLS (National Language Support). You run Auto-Loader on a host computer connected to the reader’s COM1 port. Automatic mode See Scanner mode. automatic shutoff A reader configuration feature that defines the maximum length of time the reader stays on when there is no activity. At automatic shutoff, the contents of reader memory are saved and the reader resumes where it left off when it is turned on again. backlight A light built into the reader display to make it easier to view the reader display in dimly lit environments. backup battery See lithium backup battery. BAK Bad Program Acknowledgment character. This character is sent from the reader to indicate that the IRL program received from the host could not be successfully compiled.
G-4
Page 527
Glossary
G bar code density Number of data characters that can be represented in a linear unit of measure. Often expressed in characters per inch. bar code label A label that contains a bar code symbol. bar code symbology A scheme for encoding data as bar code. Code 39, Interleaved 2 of 5, and Codabar are examples of different symbologies. battery pack See NiCad battery pack. baud rate The number of discreet conditions or signal events per second. In RS-232 and RS-422/485 systems, baud rate is the same as bits per second (bps). binary file A file that contains a sequence of 8-bit data characters or executable code. Compare to ASCII text file. Binary files require special software for transmission. See also binary file transfer. binary file transfer (BFT) The process or method for transmitting a binary file (such as an executable file) from one computer device to another. boot Usually means to invoke a bootstrap process, which involves building up a system from some simple preliminary instructions or information. Boot Loader menu The menu on the reader used to reboot the reader, to dump the reader’s RAM, to reload or upgrade the reader’s software, or to use Storage mode. Boot Utilities companion disk One of the disks that Intermec ships with your JANUS reader. This disk contains the files you need to load or upgrade the reader’s system software. This disk also contains the README.DOC, a text file that describes important information about the reader that was unavailable when this manual was published. This disk also contains a batch file, INSTALL.BAT, that you can use to install Auto-Loader onto a host computer.
G-5
Page 528
JANUS 2020 Hand-Held Computer User’s Manual bps Bits per second. The unit of measure used to describe the rate of data transmission. For example, 1200 bits per second means that there are 1200 data bits transmitted per second. BRU Base radio unit. A device that transmits messages over radio frequency (RF) waves between a controller and data collection devices. CGA Abbreviation for Color/Graphics Adapter. CGA is a video adapter board. check character A character included within a message for the purpose of performing a check to ensure the accuracy of the message. check digit A character included in a bar code whose value is used to do a mathematical check on the value of the decoded bar code to retain accuracy. client The computer from which you will access drives, directories, files, and programs that are stored on the server. See also server. Codabar A self-checking, discrete bar code symbology that has these 16 characters in its set: 0 to 9, dollar sign ($), colon (:), slash (/), period (.), plus (+), and minus (-). Codabar is commonly used in libraries, blood banks, and air-parcel express applications. The American Blood Commission (ABC) Codabar requires that you retain the start/stop code digits when processing a Codabar symbol. The maximum density for a Codabar symbol is 12.8 characters per inch. Code 2 of 5 (2 of 5) A discrete, self-checking code for encoding numeric data only. The bars encode information and the spaces separate individual bars. It can achieve densities of 15 characters per inch.
G-6
Page 529
Glossary
G
Code 11 A very high density, discrete, numeric bar code developed by Intermec. The character set includes the numbers 0 through 9 and the dash character (-). Each character is represented by a standalone group of three bars with two included spaces. This code is not self-checking. One or two check digits provide data security. Code 11 is most extensively used in labeling telecommunications components and equipment. Its maximum density is 15 characters per inch. Code 128 A very high density alphanumeric symbology that supports the extended ASCII character set. It is a variable length, continuous code that uses multiple element widths. Code 128’s high density makes it useful when printing data in a limited space. Its maximum density is 12.1 alphanumeric characters per inch or 24.2 numeric characters per inch. Code 16K A two-dimensional (stacked rows), ultra-high density bar code symbology. It is based on Code 128 and is used widely to label unit-dose packaging for the healthcare industry. Code 39 A discrete, variable length, and self-checking bar code symbology. The character set is uppercase A to Z, 0 to 9, dollar sign ($), period (.), slash (/), percent (%), space ( ), plus (+), and minus (-). Code 39 can be extended to the full 128 ASCII character set by use of a two-character encoding scheme (see full ASCII). Its maximum density is 9.8 characters per inch. Code 49 A multirow symbology for high data density. The last character in each row is used for row checking and the last two characters of the symbol are used for overall checking. The character set includes all 128 ASCII characters. Its maximum density is 93.3 alphanumeric characters per inch or 154.3 numeric characters per inch. Code 93 A variable length, continuous bar code symbology using four element widths. It can be used interchangeably with Code 39 when higher density printing is required. The character set is the same as Code 39. Its maximum density is 14.8 characters per inch.
G-7
Page 530
JANUS 2020 Hand-Held Computer User’s Manual cold boot One of two ways to boot the reader; compare to warm boot. A cold boot invokes the BIOS boot sequence, which verifies that the 256K flash system image is not corrupt, clears all memory, and performs a complete power-on self test (POST) to ensure that the hardware and peripherals are operational. The cold boot initializes the system hardware for use by system software, loads the default configuration, runs AUTOEXEC.BAT and CONFIG.SYS, and loads DOS. Because the physical RAM drive is initialized, all files on drive E are lost. You may cold boot the reader to clear the reader’s conventional memory, break out of an application that is locked in an infinite loop, or recover from an error condition. COM port Commonly used short form of communications port. Locations from which data can be passed into and out of the reader. COM ports offer serial communications, which means that data is transmitted one bit at a time over a single line from one computer to another. Communications Manager An application on the reader that lets you transmit and receive files, and see the status of the reader’s COM port. This application is available on the Application companion disk 3. communications protocol A set of rules or standards designed to enable computers to connect with each other and exchange data. An example of a communications protocol is Point-to-Point protocol. Communications Utilities Transmit and receive functions that you can call with PSK functions or software interrupts. Included in the Reader Services programs. Compound Function key The Compound Function key is a special key on the JANUS keypad. You use the key to access characters or perform functions that do not have an actual key on the keypad. When you press , the key is held in a buffer and the Compound Function key icon appears on the reader’s display. Once you press a key other than , the key combination is entered into the reader and the icon disappears from the display.
f f f configuration The selected parameters that determine the operating characteristics of an electronic device.
G-8