Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 52 of 57

JANUS 2020 Hand-Held Computer User's Manual, pages 511 to 520

Pages 511 to 520 of 570

The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec J2020 and Intermec JR2020

Page 511

NF

Syntax: (cont.)

Notes:

BC Software Utility Reference

D

/baud:rate sets a maximum baud rate for serial communication. Type 9600, 19200, 38400, 57600, or 115200. The default is 115200.

/v prevents conflicts with a computer’s timer. Include this switch if you have a serial connection between computers and one of them stops running when you use Interlnk to access a drive or printer port.

Position of the Interlnk command in the CONFIG.SYS file The position of the device command that loads INTERLNK.EXE in the CONFIG.SYS can affect pre-existing drive assignments. For example, suppose your computer includes a floppy disk drive (A), two hard disk drives (C and D), and two RAM drives (E and F). If you load the INTERLNK.EXE device driver before creating the RAM drives and you choose to redirect three drives, Interlnk assigns letters E, F, and G to the redirected drives, and letters H and I to the RAM drives. To prevent this situation from happening, load INTERLNK.EXE last in your CONFIG.SYS file. Calculating the number of drives to redirect When you add the INTERLNK.EXE command to the host computer’s CONFIG.SYS, you should set the /drives option to at least seven drives. The reader contains five default drives (C, D, E, F, G), and Interlnk assumes two more (A and B). If you specify fewer than seven drives, Interlnk will not redirect all the reader’s drives. You need more than seven drives if the reader contains more than one physical RAM drive. Saving memory The Interlnk device driver loads all of its code into memory. You can save memory by specifying the /noprinter or /com switch. If you specify the /noprinter switch, the Interlnk program does not load code that redirects printers. If you specify the /com switch, the program does not load code that supports parallel ports. Intermec recommends using the /noprinter and /com switches when INTERLNK.EXE is loaded on the reader. Using a serial mouse with Microsoft Windows If you are using a serial mouse with Microsoft Windows, specify the /com switch to designate a COM port other than the one the mouse is using. DOS version Some features of DOS may not be available to the client computer if you are running a different DOS version on your Interlnk server. For example, if you have large partitions on the server and are running DOS 3.0 on the client, the partitions are not available to the client because DOS 3.0 does not support them. Running an application located on the server If you use Interlnk to run an application located on the server, make sure the application is configured for the computer you have designated as the client.

D-5

Page 512

JANUS 2020 Hand-Held Computer User’s Manual NF BC

INTERLNK.EXE (continued) Notes: (cont.)

Limitations CHKDSK DISKCOMP DISKCOPY

These commands do not work on devices running Interlnk: FORMAT MIRROR SYS

UNDELETE UNFORMAT

Interlnk does not redirect network, CD-ROM drives, or any other device that uses a redirection interface. For example, you cannot access a network drive that was redirected before Interlnk was started. Examples:

If the Interlnk files are located in the INTERLNK directory on the host computer’s drive C and you need to specify seven drives so that drives C through G on the reader will be redirected, add this line to the CONFIG.SYS file on the reader: device=c:\interlnk\interlnk.exe /drives:7

If the Interlnk files are located in the root directory on drive D of the reader, you used the serial port to connect to another computer, and you want to start Interlnk without having the printers redirected, add this line to the CONFIG.SYS file on the reader: device=d:\interlnk.exe /com /noprinter /drives:7

To make Interlnk use a non-standard COM port whose address is 3F8, add this line to your CONFIG.SYS file on the reader: device=d:\interlnk.exe /com:3F8 /drives:7

D-6

Page 513

NF

BC Software Utility Reference

D

Intersvr Interlnk is loaded on the device designated as the client. The device running Intersvr is called the server. The server responds to commands typed on the client. When you run Intersvr in conjunction with Interlnk, it provides serial file transfer capability through redirected drives, and printing through redirected printer ports. For help installing and running Intersvr, see “Running Interlnk to Transfer Files” in Chapter 6. Type this command to begin running Intersvr: Syntax:

intersvr [drive:] [/x=drive:] [/com:n | address] [/baud:rate][/b][/v] where: drive:

specifies the letter of a drive to be redirected. By default, all drives are redirected.

/x=drive specifies a drive that is not redirected. By default, all drives are redirected.

/com:n /com:address identifies the serial COM port that is connected to the server by specifying either the number (n) or address (address) of the port. If you omit n and address, Intersvr searches all serial ports and uses the first port that it finds connected to the client. If you specify the /com switch, the server searches only for serial ports. By default, all serial ports are scanned.

Notes:

/baud:rate sets a maximum serial baud rate. Type 9600, 19200, 38400, 57600, or 115200. The default is 115200.

/b displays the Interlnk Server Status screen in black and white. Use this switch if you are having problems reading your monochrome monitor.

/v prevents conflicts with a computer’s timer. Specify this switch if you have a serial connection between computers and one of them stops running when you use Interlnk to access a drive or printer port.

Specifying the order of drives Interlnk redirects drives in the order you specify. The first server drive specified is redirected to the first available client drive, the second server drive specified is redirected to the second available client drive, and so forth.

D-7

Page 514

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Intersvr (continued) Notes: (cont.)

Copying the files from the reader If you do not have the MS-DOS Programs companion disk, which contains the Interlnk and Intersvr files, you can copy the files from the reader. You need to connect the host computer to the reader using a 7-wire, null-modem serial cable and the Mode command must be available on the host computer where you are installing Interlnk. To copy the files to the host computer, type this command on the reader: intersvr /rcopy

Using a serial mouse with Microsoft Windows If you are using a serial mouse with Microsoft Windows, and you start Intersvr while Windows is running, specify the /com switch to designate a COM port other than the one the mouse is using. Using Interlnk in a task-switching or multitasking environment If you start Intersvr in a task-switching or multitasking environment, task-switching and key combinations that switch you out of your current task are disabled. To restore these functions, quit the server. Limitations

These commands do not work on the device running Intersvr:

CHKDSK DISKCOMP DISKCOPY

FORMAT MIRROR SYS

UNDELETE UNFORMAT

Interlnk does not redirect network, CD-ROM drives, or any other device that uses a redirection interface. For example, you cannot access a network drive that was redirected before Interlnk was started. Examples:

If you have two computers and each contains drives A, B, and C, you can start Intersvr and direct server drive C to client drive D, and A to E, and B to F, by typing this command on the server: intersvr c: a: b:

To redirect all server drives except drive A and use COM4 to connect to the client, type this command on the server: intersvr /x=a /com4

D-8

Page 515

NF

BC Software Utility Reference

D

POWER.EXE POWER.EXE lets you adjust the reader’s power management at the DOS prompt. It provides power-saving features and an application program interface (API) that applications can use. POWER.EXE works through the Advanced Power Management (APM) interface. IRL programs and programs that use Reader Services do not require POWER.EXE. To change the level of power management, type this command at the reader’s DOS prompt: Syntax:

[drive:][path]power.exe [adv[:max | reg | min] | std | off][/low] where:

Notes:

drive:path specifies the location of the POWER.EXE file.

adv:max adv:reg adv:min conserves the reader’s power when applications and hardware devices are idle. Performance may be affected if an application is active instead of idle. Use max for maximum power conservation. Use reg to balance power conservation with performance. Use min (default) if performance is not satisfactory with max or reg.

std off conserves the reader’s power. Use std to conserve power by using only the power management features of your hardware. Use off to turn off POWER.EXE. If POWER.EXE is off, the date is not updated when you turn off the reader. If you use your own APM interface, it should be able to update the date each time the reader is turned on and the date has changed.

low loads POWER.EXE into conventional memory, even if the upper memory area is available. By default, POWER.EXE is loaded into upper memory if it is available.

To display the current power setting, type the command: power

You can view the power settings screen with the viewport or use Interlnk to view the settings on the host. POWER.EXE is embedded in the software and is set by default to adv:min. The JANUS 2020 has its own power management for maximum efficiency. POWER.EXE gives you an estimate of the amount of NiCad power is left in the reader’s battery pack. This estimate is accurate to ± 10 %. The accuracy of the estimate depends upon variables such as the temperature and age of the battery pack. You may find that POWER.EXE performs differently for each battery pack. For example, when POWER.EXE indicates that the battery life is at 20%, the battery pack is getting low and you need to replace it soon.

D-9

Page 516

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Auto-Loader Batch Files When you install Auto-Loader onto your host computer, eight batch files are copied to your host computer. You will use these batch files to change the contents of drive C on the reader: •

LOAD_USA.BAT or LOADLANG.BAT

•

LOADADD.BAT

•

LOADC.BAT

•

LOADIMG.BAT

•

LOADNEW.BAT

•

LOADXIMG.BAT

•

MAKE_USA.BAT or MAKELANG.BAT

•

MAKENEW.BAT

Note: The LOADC.BAT file is a master batch file called by the other batch files. This section covers these topics: •

Learning How to Use Auto-Loader

•

Moving the Batch Files

•

Using an External Power Supply

•

How to Use Each Batch File

Learning How to Use Auto-Loader Follow either of these methods to create an image file, which contains the files you want on the reader’s drive C, and then load it onto the reader:

D-10

•

Use LOAD_USA, LOADLANG, LOADADD, or LOADNEW to create and load the image file in a single step.

•

Use MAKE_USA, MAKELANG, or MAKENEW to create the image file and store it on a host computer. Then use LOADIMG or LOADXIMG to load the image file onto the reader. This two-step method helps you create an image file to be loaded onto multiple JANUS readers.

Page 517

NF

BC Software Utility Reference

D

For more help, see these chapters: Chapter 3, “Learning About the Software” Describes how to install Auto-Loader, explains why you must use special utilities to change drive C, and includes instructions for executing the commonly used batch files. Chapter 8, “Preparing the Reader for International Use” Describes how to use Auto-Loader to configure the reader to operate in a DOS National Language Support (NLS) language: French, German, Italian, or Spanish.

Moving the Batch Files The batch files are customized for the drive and directory where you installed them. To move the batch files, you must reinstall Auto-Loader. For help, see “Installing Auto-Loader on Your Host Computer” in Chapter 3.

Using an External Power Supply When you use Auto-Loader, you must connect an external power supply to the communications dock or optical link adapter. Auto-Loader uses MkImage and PutImage software. Because PutImage requires an external power supply, Auto-Loader also requires an external power supply. Caution The reader should be powered by an AC power source when you use the PutImage command in case the battery pack goes low while the flash is being erased. If the power goes down when using PutImage, the reader locks up and the system flash must be reloaded from the Boot Loader menu and you will lose data. Conseil Il faut alimenter le lecteur par une source de courant AC lors de l'exécution de la commande PutImage dans le cas où le jeu de piles s'affaiblit pendant l'effacement du flash. Si le courant est coupé lors de l'exécution de PutImage, le lecteur se verrouille, le flash système doit être rechargé du menu d'amorçage (Boot Loader) et vous perdez des données.

D-11

Page 518

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Using LOAD_USA LOAD_USA creates an image file that contains only the three startup files in the C_FILES\COMMON directory: AUTOEXEC.BAT, AUTOINST.BAT, and CONFIG.SYS. Then LOAD_USA loads the image file onto drive C, deleting all the files currently on drive C. Here is the syntax for LOAD_USA: load_usa

Note: If you installed Auto-Loader for a DOS NLS country, the LOAD_USA batch file is not installed.

USING LOADLANG LOADLANG creates an image file that contains only the three startup files in the C_FILES\COMMON directory. Then LOADLANG loads the image file onto drive C, deleting all the files currently on drive C. The LOADLANG command also edits AUTOEXEC.BAT and CONFIG.SYS to support the DOS NLS language you specified when you installed Auto-Loader. For help, see Chapter 8, “Preparing the Reader for International Use.” Here is the syntax for LOADLANG: loadlang

Note: If you installed Auto-Loader for a DOS NLS country, the LOADLANG batch file is installed instead of the LOAD_USA batch file.

Using LOADADD LOADADD adds or replaces files on the reader’s drive C without overwriting all of the files of drive C. You can also use LOADADD to configure the reader to operate in a DOS NLS language. There are two LOADADD commands: • loadadd nls

• loadadd path\filename [path\filename path\filename...] where: path is the drive and directory of the file to load.

filename is the name of the file to load.

You can specify more than one file or use path\*.* to load all the files from a directory.

D-12

Page 519

NF

BC Software Utility Reference

D

The next tables describe how the two LOADADD commands work depending on the information you include in the command and whether you installed Auto-Loader for a DOS NLS country. Command: loadadd nls DOS NLS Support? No

Description • Creates an image file that contains the three startup files in C_FILES\COMMON and all files currently on drive C. • Loads the image file onto the reader’s drive C. • Overwrites only the startup files on drive C.

Yes

• Creates an image file that contains the three startup files in C_FILES\COMMON and all files currently on drive C. • Appends commands to AUTOEXEC.BAT and CONFIG.SYS to support the DOS NLS language. • Loads the image file onto the reader’s drive C. • Overwrites only the startup files on drive C.

Command: loadadd path\filename [path\filename...] DOS NLS Support? No

Description • Creates an image file that contains files you specify in the command and all files currently on drive C. • Loads the image file onto the reader’s drive C. • Overwrites files on drive C only if the command contains a file with the same name.

Yes

• Creates an image file that contains files you specify in the command, all files currently on drive C, and the three startup files in C_FILES\COMMON unless you specify startup files in the command. • Appends commands to AUTOEXEC.BAT and CONFIG.SYS to support the DOS NLS language. • Loads the image file onto the reader’s drive C. • Overwrite files on drive C only if the command contains a file with the same name.

D-13

Page 520

JANUS 2020 Hand-Held Computer User’s Manual NF BC

Using LOADIMG LOADIMG loads the image file that you specify on the command line onto the reader’s drive C. LOADIMG overwrites all files currently on drive C. You must have created the image file already with the MAKENEW, MAKE_USA, LOADADD, LOADNEW, LOADLANG, or LOAD_USA. You may have renamed the image file from its default name, NEWDRV_C\DRIVEC.IMG. LOADIMG is useful when you are loading an image file onto multiple JANUS readers. Here is the syntax for LOADIMG: loadimg path\filename where: path is the drive and directory of the image file to load.

filename is the name of the image file to load.

Using LOADNEW LOADNEW creates an image file that contains any files you include in the command line. If you do not specify startup files in the command line, LOADNEW adds the three default startup files in C_FILES\COMMON to the image file. Then LOADNEW loads the image file onto the reader’s drive C, deleting all the files currently on drive C. If you specified a DOS NLS country when you installed Auto-Loader on the host computer, LOADNEW appends commands to the AUTOEXEC.BAT and CONFIG.SYS files to support that DOS NLS language. Here is the syntax for LOADNEW: loadnew path\filename [path\filename path\filename...] where: path is the drive and directory of the file to load.

filename is the name of the file to load.

You can specify more than one file or use path\*.* to load all the files from a directory.

D-14