Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 33 of 37

JANUS PSK for Basic, Version 2.1 Reference Manual, pages 321 to 330

Pages 321 to 330 of 362

The original document is the PDF (601 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec J2020, Intermec J2010 and Intermec J2050

Page 321

Appendix A: Status Codes

A

Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code

Severity

Subsystem

Reader Message and Description

8203

Error

CM

Invalid Param val Invalid parameter value

8204

Error

CM

Invalid Param 1 value Invalid first parameter value

8205

Error

CM

Invalid Code 39 config Invalid Code 39 configuration (HIBC and no check digit)

8206

Error

CM

Invalid param 2 value Invalid second parameter value

8207

Error

CM

Invalid Code 39 config Invalid Code 39 configuration (HIBC and full ASCII)

8208

Error

CM

Invalid Code 39 config Invalid Code 39 configuration (HIBC and mixed full ASCII)

8209

Error

CM

Invalid Param 3 value Invalid third parameter value

820A

Error

CM

Invalid Codabar cfg Invalid Codabar configuration (ABC and discard start/stop)

820B

Error

CM

Protocol not loaded

820C

Error

CM

Invalid comm or protcl Invalid port or protocol specified

820D

Error

CM

No end quote No ending quote found

820E

Error

CM

No dbl quote No double quote (might be missing an opening quote)

820F

Error

CM

Invalid parser state

8210

Error

CM

Invalid config cmd Invalid configuration command

8211

Error

CM

Client returned err Client deemed configuration command invalid

8212

Error

CM

Invalid beep duration

8213

Error

CM

Invalid beep freq Invalid beep frequency

8214

Error

CM

Invalid beep vol Invalid beep volume

A-9

Page 322

JANUS PSK for Basic Reference Manual

Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code

Severity

Subsystem

Reader Message and Description

8215

Error

CM

Beep vol alrdy off Beep volume already off

8216

Error

CM

Beep vol alrdy on Beep volume already on

8217

Error

CM

Invalid beep specifier Invalid beep specifier (must be “L” or “H”)

8218

Error

CM

Inappropriate protcl Inappropriate configuration for the current protocol

8219

Error

CM

BIOS rejected set config BIOS rejected the set configuration command

821A

Error

CM

Bld string too small Configuration command string object is too small

821B

Error

CM

Invalid Build cmd Configuration ID is invalid

821C

Error

CM

Invalid Build param Invalid build parameter

821D

Error

CM

No Build Func No build function

821E

Error

CM

No more build entries

821F

Error

CM

No more WM bld entries No more build entries in wedge lookup table

8220

Error

CM

No more WM bld entries No more build entries in wedge lookup table for “build next” WM command

8221

Error

CM

No LUM key entries No entries found in the LUM key table

8222

Error

CM

WM entry not found No match in lookup table for specified character

8223

Error

CM

Invalid Temp config At least one parameter rejected by client (see JANUS.ERR)

8224

Error

CM

Config Item not found Configuration item is not found

8225

Error

CM

File Open err File open error

A-10

Page 323

Appendix A: Status Codes

A

Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code

Severity

Subsystem

Reader Message and Description

8226

Error

CM

File Write err File write error

8227

Error

CM

File Read err File read error

8228

Error

CM

Read record too large Record too large to read

8229

Error

CM

Invalid Hex Char in esc seq Invalid hex character found in the escape sequence

822A

Error

CM

Invalid esc sequence Invalid escape sequence

822B

Error

CM

Read file not opened Read attempted on a file that was not opened

822C

Error

CM

Write file not opened Write attempted on a file that was not opened

822D

Error

CM

File close op fail File close operation failed

822E

Error

CM

Attempt close non-open file Attempt made to close a file that was not opened

822F

Error

CM

Invalid default config Invalid default configuration

8230

Error

CM

RF back not installd RF back is not installed

8231

Error

CM

RF driver not installd RF protocol handler is not installed

8232

Error

CM

Path (IMPATH) not found Path specified by IMPATH is not found

8233

Error

CM

Bld BIOS val out of range BIOS returned an invalid value during build

8234

Error

CM

Config Item not allowed by Prot Configuration item is not allowed for the selected protocol

8235

Error

CM

Config Item value out of range Configuration item value is out of range for the selected protocol

8236

Error

CM

Invalid 4th param value Invalid fourth parameter value

A-11

Page 324

JANUS PSK for Basic Reference Manual

Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code

Severity

Subsystem

Reader Message and Description

8237

Error

CM

Invalid 5th param value Invalid fifth parameter value

8238

Error

CM

Invalid 6th param value Invalid sixth parameter value

8239

Error

CM

Can’t open JANUS.ERR Unable to open JANUS.ERR file

823A

Error

CM

Radio.cfg has invalid checksum File checksum is invalid

823B

Error

CM

Invalid RF freq in RF config Invalid RF frequency specified

823C

Error

CM

Invalid RF channel in RF config Invalid channel specified

823D

Error

CM

CM_ENCODED_RF_DATA_S != CM_NUM_RF_CHANNELS Structure mismatch

823E

Error

CM

Allowed RF channels after unallowed channel Specified RF channel is not allowed

823F

Error

CM

Ping cmd not allowed here Ping command not allowed here

8240

Error

CM

Ping cmd not xmitted, prot busy Ping command not transmitted (protocol busy)

8241

Error

CM

Missing end of config cmd Missing end of configuration command

8242

Error

CM

RF freq doesn’t match RF back type RF frequency does not match the RF back

8243

Error

CM

Can’t read RF back config data Unable to read configuration data from the RF back

8244

Error

CM

Unallowed video display mode Video display mode is not allowed

8245

Error

CM

Cmd source not allowed Command source is not allowed

8246

Error

CM

Invalid 7th param value Invalid seventh parameter value

8300

Error

SC

Scanner load err Scanner load error

A-12

Page 325

Appendix A: Status Codes

A

Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code

Severity

Subsystem

Reader Message and Description

8301

Error

SC

Insufficient timers Not enough timers for the scanner to initialize

8302

Error

SC

Insufficient memory Insufficient memory for the scanner to initialize

8303

Error

SC

IPM connect failed Scanner not connected to power management

8304

Error

SC

Invalid Laser Timeout Invalid laser timeout configuration

8305

Error

SC

Counts obj integrity failed Count object integrity check failed

8306

Error

SC

Scanner vector table corrupt

8402

Error

DC

Autodiscrim table full Autodiscrimination table full

8403

Error

DC

Insufficient resources for decode

8404

Error

DC

Decode init failure Decode initialization failure due to scanner

8405

Error

DC

No scanner Decode initialization failure - no scanner present

8406

Error

DC

Invalid decodes cmd Invalid decodes command

8407

Error

DC

Symbology out of range Invalid symbology specified

840D

Error

DC

Can’t decode scan Unable to decode scan

840E

Error

DC

Missing start/stop Missing start/stop character

840F

Error

DC

Too few counts to decode

8410

Error

DC

Invalid char Invalid character found

8411

Error

DC

Invalid acceleration

8412

Error

DC

Insufficient chars for valid label Insufficient characters for valid label

8413

Error

DC

Invalid check digit

A-13

Page 326

JANUS PSK for Basic Reference Manual

Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code

Severity

Subsystem

Reader Message and Description

8414

Error

DC

Output string too short

8415

Error

DC

No leading margin

8416

Error

DC

Invalid start/stop

8417

Error

DC

Attempted decode past end of buffer Attempted decode past end of buffer (not enough counts for whole label)

8418

Error

DC

No trailing margin

8419

Error

DC

Invalid UPC supplemental

841A

Error

DC

Invalid parity

841B

Error

DC

Guard char missing Guard character missing

841C

Error

DC

Invalid row number

841D

Error

DC

Unable to scale counts

841E

Error

DC

Invalid 2 of 5 label

841F

Error

DC

Invalid 2 of 5 length

8420

Error

DC

2 of 5 label length exceeds maximum

8423

Error

DC

No valid label region found

8424

Error

DC

Ink spread exceeded threshold

8425

Error

DC

Denominator of expression zero Denominator of an expression is zero (divide by zero attempted)

8426

Error

DC

ASCII conversion failed Conversion to ASCII of full label failed

8501

Error

RW

Input request err Input request error

8504

Error

RW

Illegal RW mode Illegal reader commands parsed

8507

Error

RW

Rdr cmd parsing err Reader commands parsing error

8508

Error

RW

Invalid config Invalid configuration

850F

Error

RW

Error in rdr cmd edit Error in reader command edit

A-14

Page 327

Appendix A: Status Codes

A

Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code

Severity

Subsystem

Reader Message and Description

8511

Error

RW

Unable to allocate memory for input

8512

Error

RW

Prot handler not linked Protocol handler not linked

8514

Error

RW

Rdr cmd parsing err on exit accum Reader command parsing error on exit accumulation

8515

Error

RW

Application break detected

8516

Error

RW

Invalid Rdr Wedge request Invalid Reader Wedge request

851B

Error

RW

Rdr cmd erroneously parsed A reader command was incorrectly parsed when Enter was parsed

851F

Error

RW

Label not accepted: App not requesting input Label not accepted because the scan-ahead is not enabled and the application is not at an input statement.

8520

Error

RW

Link failed, no buffers Reader Wedge link failed

8522

Error

RW

Invalid port value for input request Invalid port specified in input request

8523

Error

RW

Xmit buffer busy or Comm Utility err returned Communications error

8524

Error

RW

Exit Accum with Comms Error Communications error from an exit accumulation command

8526

Error

RW

Invalid option in RW_DO Invalid port specified in input request

8527

Error

RW

No label symbology, no label input yet No symbology code available

8528

Error

RW

Bad parameter

8600

Error

CU

Invalid config Invalid configuration

8601

Error

CU

Buffer length 0 error

8602

Error

CU

Comm port in use

8603

Error

CU

Protocol error

8604

Error

CU

Comm port error

A-15

Page 328

JANUS PSK for Basic Reference Manual

Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code

Severity

Subsystem

Reader Message and Description

8605

Error

CU

Comm port busy

8606

Error

CU

Service not supported Communication request is not supported

8607

Error

CU

Prot handler already loaded Protocol handler already loaded

8608

Error

CU

Prot buffer error Protocol buffer error

8609

Error

CU

Unknown service request

860A

Error

CU

No data available

860B

Error

CU

ComUtil not loaded Communications utility is not loaded

860C

Error

CU

Resume/Suspend failure

860D

Error

CU

INT 14 already in use Communication utility INT 14 is already in use

860E

Error

CU

Incompatible rev PH or ComUtil Incompatible revision between the protocol handler and the communication utility

860F

Error

CU

Invalid EOF char

8610

Error

CU

Buffer must be > 256 bytes

8611

Error

CU

Prot handler not active Protocol handler is not active

8612

Error

CU

Buff size too big

8613

Error

CU

Re-entrant request for service

8614

Error

CU

H/W I/O error Hardware I/O error

86F0

Error

CU

Non-supported Comm service Non-supported communication service

8821

Error

PM

Cannot change state

8822

Error

PM

State mgr invalid cmd Invalid state manager command

8842

Error

PM

IPM interface invalid cmd Invalid IPM interface command

8843

Error

PM

Parameter out of range

A-16

Page 329

Appendix A: Status Codes

A

Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code

Severity

Subsystem

Reader Message and Description

8844

Error

PM

Semaphore max value exceeded Semaphore maximum value exceeded

8A00

Error

TM

Invalid timer func cod Invalid timer function code

8A01

Error

TM

No free timers available

8A02

Error

TM

Illegal timer mode specified

8A03

Error

TM

Timer not allocated

8A04

Error

TM

Timer currently active

8A05

Error

TM

Invalid timer delay specified

8A06

Error

TM

Invalid timer id specified

8A07

Error

TM

Timer Resume/Suspend failure

8A08

Error

TM

Cannot process user request Timer utility cannot safely process user request

8B00

Error

BP

Pitch out of range

8B01

Error

BP

Duration out of range

8B02

Error

BP

Vol out of range Volume out of range

8B03

Error

BP

Not seq or preem beep Not a sequential or preemptive beep

8B04

Error

BP

Invalid battery flag

8B05

Error

BP

No preem timer available No preemptive timer available

8B06

Error

BP

No seq timer available No sequential timer available

8B07

Error

BP

Sequence empty

8B08

Error

BP

Beep sequence not started

8B09

Error

BP

Error init beep list Error initializing beep list

8B0A

Error

BP

Beep avail list empty Beep available list empty

8B0B

Error

BP

Bad beep mgr reques Bad beep manager request

A-17

Page 330

JANUS PSK for Basic Reference Manual

Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code

Severity

Subsystem

Reader Message and Description

8B0C

Error

BP

Beep sequence full

8B0D

Error

BP

Beep in suspend state Beeper in suspend state

8B0E

Error

BP

Beeper Resume/Suspend failure

8E00

Error

IM

Substring not found

8E01

Error

IM

Extract string empty

8E02

Error

IM

Extract string too long

8E03

Error

IM

Append string overflow

8E04

Error

IM

Search string not found

8E05

Error

IM

Search string empty

8E06

Error

IM

Search string too long

8E07

Error

IM

String copy too long

8E08

Error

IM

Invalid parameter

8E09

Error

IM

Hex conversion length error

8E0A

Error

IM

Hex conversion overflow

8E0B

Error

IM

Invalid binary to ASCII radix

8E0C

Error

IM

Binary to ASCII field too small

8F00

Error

LG

Event queue empty

8F01

Error

LG

Prohibited area disable

8F02

Error

LG

Reader service disable

8F03

Error

LG

Configuration management disable

8F04

Error

LG

Scanner disable

8F05

Error

LG

Decodes disable

8F06

Error

LG

Reader Wedge disable

8F07

Error

LG

Communications utility disable

8F08

Error

LG

Protocol handler disable

8F09

Error

LG

Power management disable

8F0A

Error

LG

BIOS disable

8F0B

Error

LG

Timer disable

8F0C

Error

LG

Beeper disable