The text of a manual · part 33 of 37
JANUS PSK for Basic, Version 2.1 Reference Manual, pages 321 to 330
Pages 321 to 330 of 362
The original document is the PDF (601 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec J2020, Intermec J2010 and Intermec J2050
Page 321
Appendix A: Status Codes
A
Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code
Severity
Subsystem
Reader Message and Description
8203
Error
CM
Invalid Param val Invalid parameter value
8204
Error
CM
Invalid Param 1 value Invalid first parameter value
8205
Error
CM
Invalid Code 39 config Invalid Code 39 configuration (HIBC and no check digit)
8206
Error
CM
Invalid param 2 value Invalid second parameter value
8207
Error
CM
Invalid Code 39 config Invalid Code 39 configuration (HIBC and full ASCII)
8208
Error
CM
Invalid Code 39 config Invalid Code 39 configuration (HIBC and mixed full ASCII)
8209
Error
CM
Invalid Param 3 value Invalid third parameter value
820A
Error
CM
Invalid Codabar cfg Invalid Codabar configuration (ABC and discard start/stop)
820B
Error
CM
Protocol not loaded
820C
Error
CM
Invalid comm or protcl Invalid port or protocol specified
820D
Error
CM
No end quote No ending quote found
820E
Error
CM
No dbl quote No double quote (might be missing an opening quote)
820F
Error
CM
Invalid parser state
8210
Error
CM
Invalid config cmd Invalid configuration command
8211
Error
CM
Client returned err Client deemed configuration command invalid
8212
Error
CM
Invalid beep duration
8213
Error
CM
Invalid beep freq Invalid beep frequency
8214
Error
CM
Invalid beep vol Invalid beep volume
A-9
Page 322
JANUS PSK for Basic Reference Manual
Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code
Severity
Subsystem
Reader Message and Description
8215
Error
CM
Beep vol alrdy off Beep volume already off
8216
Error
CM
Beep vol alrdy on Beep volume already on
8217
Error
CM
Invalid beep specifier Invalid beep specifier (must be “L” or “H”)
8218
Error
CM
Inappropriate protcl Inappropriate configuration for the current protocol
8219
Error
CM
BIOS rejected set config BIOS rejected the set configuration command
821A
Error
CM
Bld string too small Configuration command string object is too small
821B
Error
CM
Invalid Build cmd Configuration ID is invalid
821C
Error
CM
Invalid Build param Invalid build parameter
821D
Error
CM
No Build Func No build function
821E
Error
CM
No more build entries
821F
Error
CM
No more WM bld entries No more build entries in wedge lookup table
8220
Error
CM
No more WM bld entries No more build entries in wedge lookup table for “build next” WM command
8221
Error
CM
No LUM key entries No entries found in the LUM key table
8222
Error
CM
WM entry not found No match in lookup table for specified character
8223
Error
CM
Invalid Temp config At least one parameter rejected by client (see JANUS.ERR)
8224
Error
CM
Config Item not found Configuration item is not found
8225
Error
CM
File Open err File open error
A-10
Page 323
Appendix A: Status Codes
A
Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code
Severity
Subsystem
Reader Message and Description
8226
Error
CM
File Write err File write error
8227
Error
CM
File Read err File read error
8228
Error
CM
Read record too large Record too large to read
8229
Error
CM
Invalid Hex Char in esc seq Invalid hex character found in the escape sequence
822A
Error
CM
Invalid esc sequence Invalid escape sequence
822B
Error
CM
Read file not opened Read attempted on a file that was not opened
822C
Error
CM
Write file not opened Write attempted on a file that was not opened
822D
Error
CM
File close op fail File close operation failed
822E
Error
CM
Attempt close non-open file Attempt made to close a file that was not opened
822F
Error
CM
Invalid default config Invalid default configuration
8230
Error
CM
RF back not installd RF back is not installed
8231
Error
CM
RF driver not installd RF protocol handler is not installed
8232
Error
CM
Path (IMPATH) not found Path specified by IMPATH is not found
8233
Error
CM
Bld BIOS val out of range BIOS returned an invalid value during build
8234
Error
CM
Config Item not allowed by Prot Configuration item is not allowed for the selected protocol
8235
Error
CM
Config Item value out of range Configuration item value is out of range for the selected protocol
8236
Error
CM
Invalid 4th param value Invalid fourth parameter value
A-11
Page 324
JANUS PSK for Basic Reference Manual
Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code
Severity
Subsystem
Reader Message and Description
8237
Error
CM
Invalid 5th param value Invalid fifth parameter value
8238
Error
CM
Invalid 6th param value Invalid sixth parameter value
8239
Error
CM
Can’t open JANUS.ERR Unable to open JANUS.ERR file
823A
Error
CM
Radio.cfg has invalid checksum File checksum is invalid
823B
Error
CM
Invalid RF freq in RF config Invalid RF frequency specified
823C
Error
CM
Invalid RF channel in RF config Invalid channel specified
823D
Error
CM
CM_ENCODED_RF_DATA_S != CM_NUM_RF_CHANNELS Structure mismatch
823E
Error
CM
Allowed RF channels after unallowed channel Specified RF channel is not allowed
823F
Error
CM
Ping cmd not allowed here Ping command not allowed here
8240
Error
CM
Ping cmd not xmitted, prot busy Ping command not transmitted (protocol busy)
8241
Error
CM
Missing end of config cmd Missing end of configuration command
8242
Error
CM
RF freq doesn’t match RF back type RF frequency does not match the RF back
8243
Error
CM
Can’t read RF back config data Unable to read configuration data from the RF back
8244
Error
CM
Unallowed video display mode Video display mode is not allowed
8245
Error
CM
Cmd source not allowed Command source is not allowed
8246
Error
CM
Invalid 7th param value Invalid seventh parameter value
8300
Error
SC
Scanner load err Scanner load error
A-12
Page 325
Appendix A: Status Codes
A
Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code
Severity
Subsystem
Reader Message and Description
8301
Error
SC
Insufficient timers Not enough timers for the scanner to initialize
8302
Error
SC
Insufficient memory Insufficient memory for the scanner to initialize
8303
Error
SC
IPM connect failed Scanner not connected to power management
8304
Error
SC
Invalid Laser Timeout Invalid laser timeout configuration
8305
Error
SC
Counts obj integrity failed Count object integrity check failed
8306
Error
SC
Scanner vector table corrupt
8402
Error
DC
Autodiscrim table full Autodiscrimination table full
8403
Error
DC
Insufficient resources for decode
8404
Error
DC
Decode init failure Decode initialization failure due to scanner
8405
Error
DC
No scanner Decode initialization failure - no scanner present
8406
Error
DC
Invalid decodes cmd Invalid decodes command
8407
Error
DC
Symbology out of range Invalid symbology specified
840D
Error
DC
Can’t decode scan Unable to decode scan
840E
Error
DC
Missing start/stop Missing start/stop character
840F
Error
DC
Too few counts to decode
8410
Error
DC
Invalid char Invalid character found
8411
Error
DC
Invalid acceleration
8412
Error
DC
Insufficient chars for valid label Insufficient characters for valid label
8413
Error
DC
Invalid check digit
A-13
Page 326
JANUS PSK for Basic Reference Manual
Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code
Severity
Subsystem
Reader Message and Description
8414
Error
DC
Output string too short
8415
Error
DC
No leading margin
8416
Error
DC
Invalid start/stop
8417
Error
DC
Attempted decode past end of buffer Attempted decode past end of buffer (not enough counts for whole label)
8418
Error
DC
No trailing margin
8419
Error
DC
Invalid UPC supplemental
841A
Error
DC
Invalid parity
841B
Error
DC
Guard char missing Guard character missing
841C
Error
DC
Invalid row number
841D
Error
DC
Unable to scale counts
841E
Error
DC
Invalid 2 of 5 label
841F
Error
DC
Invalid 2 of 5 length
8420
Error
DC
2 of 5 label length exceeds maximum
8423
Error
DC
No valid label region found
8424
Error
DC
Ink spread exceeded threshold
8425
Error
DC
Denominator of expression zero Denominator of an expression is zero (divide by zero attempted)
8426
Error
DC
ASCII conversion failed Conversion to ASCII of full label failed
8501
Error
RW
Input request err Input request error
8504
Error
RW
Illegal RW mode Illegal reader commands parsed
8507
Error
RW
Rdr cmd parsing err Reader commands parsing error
8508
Error
RW
Invalid config Invalid configuration
850F
Error
RW
Error in rdr cmd edit Error in reader command edit
A-14
Page 327
Appendix A: Status Codes
A
Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code
Severity
Subsystem
Reader Message and Description
8511
Error
RW
Unable to allocate memory for input
8512
Error
RW
Prot handler not linked Protocol handler not linked
8514
Error
RW
Rdr cmd parsing err on exit accum Reader command parsing error on exit accumulation
8515
Error
RW
Application break detected
8516
Error
RW
Invalid Rdr Wedge request Invalid Reader Wedge request
851B
Error
RW
Rdr cmd erroneously parsed A reader command was incorrectly parsed when Enter was parsed
851F
Error
RW
Label not accepted: App not requesting input Label not accepted because the scan-ahead is not enabled and the application is not at an input statement.
8520
Error
RW
Link failed, no buffers Reader Wedge link failed
8522
Error
RW
Invalid port value for input request Invalid port specified in input request
8523
Error
RW
Xmit buffer busy or Comm Utility err returned Communications error
8524
Error
RW
Exit Accum with Comms Error Communications error from an exit accumulation command
8526
Error
RW
Invalid option in RW_DO Invalid port specified in input request
8527
Error
RW
No label symbology, no label input yet No symbology code available
8528
Error
RW
Bad parameter
8600
Error
CU
Invalid config Invalid configuration
8601
Error
CU
Buffer length 0 error
8602
Error
CU
Comm port in use
8603
Error
CU
Protocol error
8604
Error
CU
Comm port error
A-15
Page 328
JANUS PSK for Basic Reference Manual
Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code
Severity
Subsystem
Reader Message and Description
8605
Error
CU
Comm port busy
8606
Error
CU
Service not supported Communication request is not supported
8607
Error
CU
Prot handler already loaded Protocol handler already loaded
8608
Error
CU
Prot buffer error Protocol buffer error
8609
Error
CU
Unknown service request
860A
Error
CU
No data available
860B
Error
CU
ComUtil not loaded Communications utility is not loaded
860C
Error
CU
Resume/Suspend failure
860D
Error
CU
INT 14 already in use Communication utility INT 14 is already in use
860E
Error
CU
Incompatible rev PH or ComUtil Incompatible revision between the protocol handler and the communication utility
860F
Error
CU
Invalid EOF char
8610
Error
CU
Buffer must be > 256 bytes
8611
Error
CU
Prot handler not active Protocol handler is not active
8612
Error
CU
Buff size too big
8613
Error
CU
Re-entrant request for service
8614
Error
CU
H/W I/O error Hardware I/O error
86F0
Error
CU
Non-supported Comm service Non-supported communication service
8821
Error
PM
Cannot change state
8822
Error
PM
State mgr invalid cmd Invalid state manager command
8842
Error
PM
IPM interface invalid cmd Invalid IPM interface command
8843
Error
PM
Parameter out of range
A-16
Page 329
Appendix A: Status Codes
A
Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code
Severity
Subsystem
Reader Message and Description
8844
Error
PM
Semaphore max value exceeded Semaphore maximum value exceeded
8A00
Error
TM
Invalid timer func cod Invalid timer function code
8A01
Error
TM
No free timers available
8A02
Error
TM
Illegal timer mode specified
8A03
Error
TM
Timer not allocated
8A04
Error
TM
Timer currently active
8A05
Error
TM
Invalid timer delay specified
8A06
Error
TM
Invalid timer id specified
8A07
Error
TM
Timer Resume/Suspend failure
8A08
Error
TM
Cannot process user request Timer utility cannot safely process user request
8B00
Error
BP
Pitch out of range
8B01
Error
BP
Duration out of range
8B02
Error
BP
Vol out of range Volume out of range
8B03
Error
BP
Not seq or preem beep Not a sequential or preemptive beep
8B04
Error
BP
Invalid battery flag
8B05
Error
BP
No preem timer available No preemptive timer available
8B06
Error
BP
No seq timer available No sequential timer available
8B07
Error
BP
Sequence empty
8B08
Error
BP
Beep sequence not started
8B09
Error
BP
Error init beep list Error initializing beep list
8B0A
Error
BP
Beep avail list empty Beep available list empty
8B0B
Error
BP
Bad beep mgr reques Bad beep manager request
A-17
Page 330
JANUS PSK for Basic Reference Manual
Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code
Severity
Subsystem
Reader Message and Description
8B0C
Error
BP
Beep sequence full
8B0D
Error
BP
Beep in suspend state Beeper in suspend state
8B0E
Error
BP
Beeper Resume/Suspend failure
8E00
Error
IM
Substring not found
8E01
Error
IM
Extract string empty
8E02
Error
IM
Extract string too long
8E03
Error
IM
Append string overflow
8E04
Error
IM
Search string not found
8E05
Error
IM
Search string empty
8E06
Error
IM
Search string too long
8E07
Error
IM
String copy too long
8E08
Error
IM
Invalid parameter
8E09
Error
IM
Hex conversion length error
8E0A
Error
IM
Hex conversion overflow
8E0B
Error
IM
Invalid binary to ASCII radix
8E0C
Error
IM
Binary to ASCII field too small
8F00
Error
LG
Event queue empty
8F01
Error
LG
Prohibited area disable
8F02
Error
LG
Reader service disable
8F03
Error
LG
Configuration management disable
8F04
Error
LG
Scanner disable
8F05
Error
LG
Decodes disable
8F06
Error
LG
Reader Wedge disable
8F07
Error
LG
Communications utility disable
8F08
Error
LG
Protocol handler disable
8F09
Error
LG
Power management disable
8F0A
Error
LG
BIOS disable
8F0B
Error
LG
Timer disable
8F0C
Error
LG
Beeper disable
A-18