Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 32 of 37

JANUS PSK for Basic, Version 2.1 Reference Manual, pages 311 to 320

Pages 311 to 320 of 362

The original document is the PDF (601 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec J2020, Intermec J2010 and Intermec J2050

Page 311

imViewportSetxy – Visual Basic

3

Example '**************** imViewportSetxy ****************** REM $INCLUDE: 'im20vbas.bi' ' Viewport Set X and Y coordinates ' Prompt for row and col INPUT "Enter row ", dpRow% INPUT "Enter column ", dpColumn% status% = imViewportSetxy (VARPTR(dpRow%), VARSEG(dpRow%), VARPTR(dpColumn%), VARSEG(dpColumn%)) temp$ = INPUT$(1) PRINT "VP Set XY status =" PRINT " ", HEX$(status%) SLEEP 5 END

3-145

Page 312

imViewportToCursor – Visual Basic imViewportToCursor Purpose:

This function centers the viewport around the cursor.

Syntax:

REM $INCLUDE: 'im20vbas.bi' SUB imViewportToCursor ()

IN Parameters:

None.

OUT Parameters:

None.

Return Value:

None.

Notes:

When the cursor is not displayed, use this function to move the viewport to the cursor. This function has no effect on the JANUS 2050.

See Also:

imCursorToViewport, imViewportEnd, imViewportHome, imViewportPageDown, imViewportMove

Example '**************** imViewportToCursor *************** REM $INCLUDE: 'im20vbas.bi' ' Call viewport to cursor imViewportToCursor SLEEP 5 END

3-146

Page 313

A Appendix A: Status Codes

Page 314

This page is a scan with no text; see it in the PDF.

Page 315

A

Appendix A: Status Codes

This appendix lists the status code hex values and error messages. Use the tables in this appendix to look up the meaning of a specific status code.

Status Code Bit Values Most of the PSK functions return status codes. You can use the codes to test for error conditions that your application will act upon. Each status code is a 16-bit word structured as follows: 15

14

13

12

10

9

8

7

6

5

4

3

2

1

0 s s f f f f f m m m m m m m m

JPSK.002 where: s is severity code:

00 = Success 10 = Error 01 = Warning 11 = Fatal f is the subsystem code, explained later in this appendix. m is the message code that identifies the error or warning condition. The status codes are IM_USHORT (unsigned short) values. The tables in this appendix list the hex value of the message codes.

A-3

Page 316

JANUS PSK for Basic Reference Manual

Status Codes Listed Numerically The following table lists the return codes and the error message text provided by im_message and imMessage. For each message, there is an associated status return code, subsystem, and severity. Some messages are abbreviated to fit the display and to save memory on the JANUS reader. The table includes an easy-to-read version of the abbreviated messages.

Status Codes and Error Messages Listed in Numerical Order Hex Code

Severity

Subsystem

Reader Message and Description

0000

Good

NO

Request successful

0001

Good

NO

Prohibited

0100

Good

RS

Rservice request success Reader services successful

0103

Good

RS

Rservice resume success Reader services resume successful

0200

Good

CM

Request success Request successful

0201

Good

CM

Read End Of Record End of record reached

0202

Good

CM

Read End Of File End of file reached

0300

Good

SC

Scan success Scan successful

0400

Good

DC

Success Successful command

0401

Good

DC

Symbology already enabled Symbology is already enabled

0402

Good

DC

Symbology not enabled Symbology is not enabled

040A

Good

DC

Good decode Successful decode

040B

Good

DC

Intermediate row re-read Intermediate row reread

A-4

Page 317

Appendix A: Status Codes

A

Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code

Severity

Subsystem

Reader Message and Description

040C

Good

DC

Intermediate decoded Intermediate raw decoded

0421

Good

DC

Default command symbology

0422

Good

DC

Mixed ASCII format

0500

Good

RW

RW success Reader Wedge successful

0505

Good

RW

No rdr cmds parsed No reader commands parsed

0506

Good

RW

Valid rdr cmds parsed Valid reader commands parsed

0509

Good

RW

Accumulating rdr cmd Accumulating reader command

050A

Good

RW

Rdr cmd override Reader command override

050B

Good

RW

Rdr cmd enter accum Reader command enter accumulation

050C

Good

RW

Rdr cmd exit accum Reader command exit accumulation

050D

Good

RW

Accumulate multi-read labels Accumulating multiread labels

0510

Good

RW

ENTER rdr cmd parsed An Enter reader command was parsed

0513

Good

RW

Protected field rdr cmd parsed Protected field was parsed

0517

Good

RW

Keycode label parsed Keycode label was parsed

0518

Good

RW

Isolated ENTER cmd parsed An isolated Enter command was parsed

0519

Good

RW

Good rdr cmd on exit accum A reader command was parsed successfully on exit from accumulation

051A

Good

RW

Good rdr cmd on ENTER A reader command was parsed successfully when Enter was parsed

A-5

Page 318

JANUS PSK for Basic Reference Manual

Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code

Severity

Subsystem

Reader Message and Description

051C

Good

RW

Enter accum parsed An Enter Accumulate has been parsed when accumulating

051D

Good

RW

Exit multi-read A label terminating a multiple-read sequence was scanned

051E

Good

RW

Enter multi-read A label beginning a multiple-read sequence was scanned

0521

Good

RW

No comms status No communications status to report

0525

Good

RW

Rdr cmds parsed Reader commands forwarded to the application were parsed

0600

Good

CU

Comm success Communications operation success

0601

Good

CU

Comm Buff done Communications buffer done

0800

Good

PM

PM success Power management successful

0A00

Good

TM

Timer success Timer operation successful

0B00

Good

BP

Beep success Beeper call successful

0E00

Good

IM

String Extract Complete

0E01

Good

IM

String Append complete

0E02

Good

IM

Search string found

0E03

Good

IM

String Copy complete

0E04

Good

IM

Operation success Successful operation

0F00

Good

LG

Successful operation

1000

Good

KB

Expanded keypad success Expanded keyboard buffer successful

100A

Good

KB

Expanded buffer enabled

100B

Good

KB

Expanded buffer disabled

1100

Good

SS

System Config success System configuration successful

A-6

Page 319

Appendix A: Status Codes

A

Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code

Severity

Subsystem

Reader Message and Description

1200

Good

KP

Keypad success Successful keypad operation

1300

Good

DP

Display success Successful display operation

1A00

Good

EX

Execution success Transaction successful

1A01

Good

EX

ACK received Transaction successful, ACK received

1A10

Good

EX

Data received Received host message on Read operation

4200

Warning

CM

Not all config items copied Not all configuration items copied

4201

Warning

CM

Rdr Cmd terminated config cmd Reader command terminated configuration command string

4202

Warning

CM

Client should not be notified

4502

Warning

RW

Input timeout

4503

Warning

RW

No input data

450E

Warning

RW

The app should be notified The application should be notified

4529

Warning

RW

Input from source other than requested Input from source is other than the ones requested

452A

Warning

RW

RWTSR already loaded

4600

Warning

CU

Warning buff canceled Buffer canceled

4601

Warning

CU

Comm Timeout warning Communication timeout

4602

Warning

CU

Comm had no client to cancel Communication had no client to cancel

4603

Warning

CU

Comm Util no PH for config No protocol handler to configure

4604

Warning

CU

Prot handler not loaded Protocol handler is not yet loaded

4605

Warning

CU

Prot handler already receiving Protocol handler is already receiving

A-7

Page 320

JANUS PSK for Basic Reference Manual

Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code

Severity

Subsystem

Reader Message and Description

4606

Warning

CU

PH not active for link request Protocol handler is not active for link request

4A00

Warning

TM

Timer not active Timer not currently active

5001

Warning

KB

Expanded buffer installed Expanded keyboard buffer installed or disabled

5201

Warning

KP

Backdoor Comms failed Backdoor communications failure

5A02

Warning

EX

NAK received Transaction failed, NAK received

5A07

Warning

EX

No more log records Standby file is empty

5A11

Warning

EX

Received data truncated Data was truncated

5A12

Warning

EX

Fields overflow Too many fields

5A20

Warning

EX

Record logged Record stored in standby file successfully

5A21

Warning

EX

Logged but upload error Record stored in standby file, but upload standby error

8100

Error

RS

Rservice invalid request code Invalid function code received

8101

Error

RS

Rservice not installed Reader services is not installed

8102

Error

RS

Rservice resume failed Reader services resume failed

8103

Error

RS

Rservice or App out of date Reader services or application is out of date

8104

Error

RS

RWTSR not connected Reader Wedge TSR is not installed

8200

Error

CM

Invalid Object

8201

Error

CM

Invalid subfunction

8202

Error

CM

Invalid Param length Invalid parameter length