The text of a manual · part 21 of 25
JANUS PSK for Ada Reference Manual, pages 201 to 210
Pages 201 to 210 of 250
The original document is the PDF (415 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec J2020, Intermec J2010 and Intermec J2050
Page 201
Appendix A: Status Codes
A
Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code
Severity
Subsystem
Reader Message and Description
8301
Error
SC
Insufficient timers Not enough timers for the scanner to initialize
8302
Error
SC
Insufficient memory Insufficient memory for the scanner to initialize
8303
Error
SC
IPM connect failed Scanner not connected to power management
8304
Error
SC
Invalid Laser Timeout Invalid laser timeout configuration
8305
Error
SC
Counts obj integrity failed Count object integrity check failed
8306
Error
SC
Scanner vector table corrupt
8402
Error
DC
Autodiscrim table full Autodiscrimination table full
8403
Error
DC
Insufficient resources for decode
8404
Error
DC
Decode init failure Decode initialization failure due to scanner
8405
Error
DC
No scanner Decode initialization failure - no scanner present
8406
Error
DC
Invalid decodes cmd Invalid decodes command
8407
Error
DC
Symbology out of range Invalid symbology specified
840D
Error
DC
Can’t decode scan Unable to decode scan
840E
Error
DC
Missing start/stop Missing start/stop character
840F
Error
DC
Too few counts to decode
8410
Error
DC
Invalid char Invalid character found
8411
Error
DC
Invalid acceleration
8412
Error
DC
Insufficient chars for valid label Insufficient characters for valid label
8413
Error
DC
Invalid check digit
A-13
Page 202
JANUS PSK for Ada Reference Manual
Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code
Severity
Subsystem
Reader Message and Description
8414
Error
DC
Output string too short
8415
Error
DC
No leading margin
8416
Error
DC
Invalid start/stop
8417
Error
DC
Attempted decode past end of buffer Attempted decode past end of buffer (not enough counts for whole label)
8418
Error
DC
No trailing margin
8419
Error
DC
Invalid UPC supplemental
841A
Error
DC
Invalid parity
841B
Error
DC
Guard char missing Guard character missing
841C
Error
DC
Invalid row number
841D
Error
DC
Unable to scale counts
841E
Error
DC
Invalid 2 of 5 label
841F
Error
DC
Invalid 2 of 5 length
8420
Error
DC
2 of 5 label length exceeds maximum
8423
Error
DC
No valid label region found
8424
Error
DC
Ink spread exceeded threshold
8425
Error
DC
Denominator of expression zero Denominator of an expression is zero (divide by zero attempted)
8426
Error
DC
ASCII conversion failed Conversion to ASCII of full label failed
8501
Error
RW
Input request err Input request error
8504
Error
RW
Illegal RW mode Illegal reader commands parsed
8507
Error
RW
Rdr cmd parsing err Reader commands parsing error
8508
Error
RW
Invalid config Invalid configuration
850F
Error
RW
Error in rdr cmd edit Error in reader command edit
A-14
Page 203
Appendix A: Status Codes
A
Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code
Severity
Subsystem
Reader Message and Description
8511
Error
RW
Unable to allocate memory for input
8512
Error
RW
Prot handler not linked Protocol handler not linked
8514
Error
RW
Rdr cmd parsing err on exit accum Reader command parsing error on exit accumulation
8515
Error
RW
Application break detected
8516
Error
RW
Invalid Rdr Wedge request Invalid Reader Wedge request
851B
Error
RW
Rdr cmd erroneously parsed A reader command was incorrectly parsed when Enter was parsed
851F
Error
RW
Label not accepted: App not requesting input Label not accepted because the scan-ahead is not enabled and the application is not at an input statement.
8520
Error
RW
Link failed, no buffers Reader Wedge link failed
8522
Error
RW
Invalid port value for input request Invalid port specified in input request
8523
Error
RW
Xmit buffer busy or Comm Utility err returned Communications error
8524
Error
RW
Exit Accum with Comms Error Communications error from an exit accumulation command
8526
Error
RW
Invalid option in RW_DO Invalid port specified in input request
8527
Error
RW
No label symbology, no label input yet No symbology code available
8528
Error
RW
Bad parameter
8600
Error
CU
Invalid config Invalid configuration
8601
Error
CU
Buffer length 0 error
8602
Error
CU
Comm port in use
8603
Error
CU
Protocol error
8604
Error
CU
Comm port error
A-15
Page 204
JANUS PSK for Ada Reference Manual
Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code
Severity
Subsystem
Reader Message and Description
8605
Error
CU
Comm port busy
8606
Error
CU
Service not supported Communication request is not supported
8607
Error
CU
Prot handler already loaded Protocol handler already loaded
8608
Error
CU
Prot buffer error Protocol buffer error
8609
Error
CU
Unknown service request
860A
Error
CU
No data available
860B
Error
CU
ComUtil not loaded Communications utility is not loaded
860C
Error
CU
Resume/Suspend failure
860D
Error
CU
INT 14 already in use Communication utility INT 14 is already in use
860E
Error
CU
Incompatible rev PH or ComUtil Incompatible revision between the protocol handler and the communication utility
860F
Error
CU
Invalid EOF char
8610
Error
CU
Buffer must be > 256 bytes
8611
Error
CU
Prot handler not active Protocol handler is not active
8612
Error
CU
Buff size too big
8613
Error
CU
Re-entrant request for service
8614
Error
CU
H/W I/O error Hardware I/O error
86F0
Error
CU
Non-supported Comm service Non-supported communication service
8821
Error
PM
Cannot change state
8822
Error
PM
State mgr invalid cmd Invalid state manager command
8842
Error
PM
IPM interface invalid cmd Invalid IPM interface command
8843
Error
PM
Parameter out of range
A-16
Page 205
Appendix A: Status Codes
A
Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code
Severity
Subsystem
Reader Message and Description
8844
Error
PM
Semaphore max value exceeded Semaphore maximum value exceeded
8A00
Error
TM
Invalid timer func cod Invalid timer function code
8A01
Error
TM
No free timers available
8A02
Error
TM
Illegal timer mode specified
8A03
Error
TM
Timer not allocated
8A04
Error
TM
Timer currently active
8A05
Error
TM
Invalid timer delay specified
8A06
Error
TM
Invalid timer id specified
8A07
Error
TM
Timer Resume/Suspend failure
8A08
Error
TM
Cannot process user request Timer utility cannot safely process user request
8B00
Error
BP
Pitch out of range
8B01
Error
BP
Duration out of range
8B02
Error
BP
Vol out of range Volume out of range
8B03
Error
BP
Not seq or preem beep Not a sequential or preemptive beep
8B04
Error
BP
Invalid battery flag
8B05
Error
BP
No preem timer available No preemptive timer available
8B06
Error
BP
No seq timer available No sequential timer available
8B07
Error
BP
Sequence empty
8B08
Error
BP
Beep sequence not started
8B09
Error
BP
Error init beep list Error initializing beep list
8B0A
Error
BP
Beep avail list empty Beep available list empty
8B0B
Error
BP
Bad beep mgr reques Bad beep manager request
A-17
Page 206
JANUS PSK for Ada Reference Manual
Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code
Severity
Subsystem
Reader Message and Description
8B0C
Error
BP
Beep sequence full
8B0D
Error
BP
Beep in suspend state Beeper in suspend state
8B0E
Error
BP
Beeper Resume/Suspend failure
8E00
Error
IM
Substring not found
8E01
Error
IM
Extract string empty
8E02
Error
IM
Extract string too long
8E03
Error
IM
Append string overflow
8E04
Error
IM
Search string not found
8E05
Error
IM
Search string empty
8E06
Error
IM
Search string too long
8E07
Error
IM
String copy too long
8E08
Error
IM
Invalid parameter
8E09
Error
IM
Hex conversion length error
8E0A
Error
IM
Hex conversion overflow
8E0B
Error
IM
Invalid binary to ASCII radix
8E0C
Error
IM
Binary to ASCII field too small
8F00
Error
LG
Event queue empty
8F01
Error
LG
Prohibited area disable
8F02
Error
LG
Reader service disable
8F03
Error
LG
Configuration management disable
8F04
Error
LG
Scanner disable
8F05
Error
LG
Decodes disable
8F06
Error
LG
Reader Wedge disable
8F07
Error
LG
Communications utility disable
8F08
Error
LG
Protocol handler disable
8F09
Error
LG
Power management disable
8F0A
Error
LG
BIOS disable
8F0B
Error
LG
Timer disable
8F0C
Error
LG
Beeper disable
A-18
Page 207
Appendix A: Status Codes
A
Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code
Severity
Subsystem
Reader Message and Description
8F0D
Error
LG
IRL desktop disable
8F0E
Error
LG
Prompting configuration disable
8F0F
Error
LG
Intermec library disabled
8F10
Error
LG
Event logger disable
8F11
Error
LG
Keyboard disable
8F12
Error
LG
System configuration disable
8F13
Error
LG
Keypad disable
8F14
Error
LG
Display disable
8F15
Error
LG
Communications manager disable
8F16
Error
LG
Workbench disable
8F17
Error
LG
Severity success disable
8F18
Error
LG
Severity warning disable
8F19
Error
LG
Severity error disable
8F1A
Error
LG
Severity fatal disable
8F1B
Error
LG
Wrong subsystem ID entered
8F1C
Error
LG
Wrong severity ID entered
9002
Error
KB
Can’t disable not empty buffer Cannot disable because buffer is not empty
9003
Error
KB
Keypad buffer full Keyboard buffer is full, entire string rejected
9004
Error
KB
Expanded buffer not installed Expanded keyboard buffer not installed
9005
Error
KB
Invalid mode value was passed
9006
Error
KB
Exp buffer flush not install Expanded keyboard buffer flush failed
9007
Error
KB
Undefined message
9008
Error
KB
16.B3 err:Source str > dest bufr Source string exceeds source or destination buffer size
9009
Error
KB
16.B3 err:Unknown str descriptor String descriptor type is unknown
900C
Error
KB
Invalid option requested from int 16 B4xxh
A-19
Page 208
JANUS PSK for Ada Reference Manual
Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code
Severity
Subsystem
Reader Message and Description
9100
Error
SS
Invalid service number
9101
Error
SS
ASIC bit number out of range
9102
Error
SS
Unknown ASIC I/O address
9103
Error
SS
Undefined message code
9104
Error
SS
Invalid COM Port id Invalid communications port ID
9105
Error
SS
Invalid Args Invalid Argument
9200
Error
KP
Timeout mid. transaction Timeout occurred in the middle of a transaction
9201
Error
KP
Timeout 1st transaction Timeout occurred on the first transaction
9202
Error
KP
Keypad busy
9203
Error
KP
Forced transaction abort
9204
Error
KP
Failed to process command
9205
Error
KP
Invalid func number Invalid function number
9206
Error
KP
Invalid keypad comms status Invalid keypad communications status
9207
Error
KP
Passed in wrong parameter
9208
Error
KP
BIOS returned invalid value
9300
Error
DP
Abs value out range Absolute value out range
9301
Error
DP
Invalid display size mode
9302
Error
DP
Display function undefined
9303
Error
DP
Invalid backlight timeout value
9304
Error
DP
Display BIOS returned an invalid status
9305
Error
DP
Invalid viewport mode
9306
Error
DP
Invalid scroll mode
9307
Error
DP
Invalid video mode
9308
Error
DP
Invalid size mode
A-20
Page 209
Appendix A: Status Codes
A
Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code
Severity
Subsystem
Reader Message and Description
9309
Error
DP
Invalid height mode Invalid character height mode
9A03
Error
EX
Transmit fail
9A04
Error
EX
Receive timeout
9A05
Error
EX
Packet header error
9A06
Error
EX
Transaction ID missing
9A08
Error
EX
Standby file missing
9A09
Error
EX
Standby file I/O error
9A40
Error
EX
Buffer overflow Host response buffer is too small
9A41
Error
EX
Buffer overflow and upload standby error
A-21
Page 210
JANUS PSK for Ada Reference Manual
Status Codes Listed by Subsystem The status codes in the following tables are organized by subsystems. To find a particular status code, identify the subsystem by looking at bits 8 through 13 and refer to that section:
A-22
Code
Abbrev.
Name
0100
RS
Reader Services
0200
CM
Configuration Management
0300
SC
Scanner
0400
DC
Decodes
0500
RW
Reader Wedge
0600
CU
Communications
0800
PM
Power Management
0A00
TM
Timer
0B00
BP
Beep
0E00
IM
Intermec Library
0F00
LG
Event Logger
1000
KB
Keyboard Buffer
1100
SS
System Configuration
1200
KP
Keypad Services
1300
DP
Display