Appendix A: Status Codes
This appendix lists the status code hex values and error messages. Use the tables in this appendix to look up the meaning of a specific status code.
Status Code Bit Values Most of the PSK functions return status codes. You can use the codes to test for error conditions that your application will act upon. How you test for the status codes depends on the complexity of the function returning the status and your application needs. In some cases, you may use the status code macros discussed in “Status Code Macros” in Chapter 2 to check the severity level. In other cases, you may want to check the exact status code value. Each status code is a 16-bit word structured as follows: 15
14
13
12
10
9
8
7
6
5
4
3
2
1
0 s s f f f f f m m m m m m m m
JPSK.002 where: s is severity code:
00 = Success 10 = Error 01 = Warning 11 = Fatal f is the subsystem code, explained later in this appendix. m is the message code that identifies the error or warning condition. The status codes are IM_USHORT (unsigned short) values. The tables in this appendix list the hex value of the message codes.
A-3
Page 192
JANUS PSK for Ada Reference Manual
Status Codes Listed Numerically The following table lists the return codes and the error message text provided by im_message and imMessage. For each message, there is an associated status return code, subsystem, and severity. Some messages are abbreviated to fit the display and to save memory on the JANUS reader. The table includes an easy-to-read version of the abbreviated messages.
Status Codes and Error Messages Listed in Numerical Order Hex Code
Severity
Subsystem
Reader Message and Description
0000
Good
NO
Request successful
0001
Good
NO
Prohibited
0100
Good
RS
Rservice request success Reader services successful
0103
Good
RS
Rservice resume success Reader services resume successful
0200
Good
CM
Request success Request successful
0201
Good
CM
Read End Of Record End of record reached
0202
Good
CM
Read End Of File End of file reached
0300
Good
SC
Scan success Scan successful
0400
Good
DC
Success Successful command
0401
Good
DC
Symbology already enabled Symbology is already enabled
0402
Good
DC
Symbology not enabled Symbology is not enabled
040A
Good
DC
Good decode Successful decode
040B
Good
DC
Intermediate row re-read Intermediate row reread
A-4
Page 193
Appendix A: Status Codes
A
Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code
Severity
Subsystem
Reader Message and Description
040C
Good
DC
Intermediate decoded Intermediate raw decoded
0421
Good
DC
Default command symbology
0422
Good
DC
Mixed ASCII format
0500
Good
RW
RW success Reader Wedge successful
0505
Good
RW
No rdr cmds parsed No reader commands parsed
0506
Good
RW
Valid rdr cmds parsed Valid reader commands parsed
0509
Good
RW
Accumulating rdr cmd Accumulating reader command
050A
Good
RW
Rdr cmd override Reader command override
050B
Good
RW
Rdr cmd enter accum Reader command enter accumulation
050C
Good
RW
Rdr cmd exit accum Reader command exit accumulation
050D
Good
RW
Accumulate multi-read labels Accumulating multiread labels
0510
Good
RW
ENTER rdr cmd parsed An Enter reader command was parsed
0513
Good
RW
Protected field rdr cmd parsed Protected field was parsed
0517
Good
RW
Keycode label parsed Keycode label was parsed
0518
Good
RW
Isolated ENTER cmd parsed An isolated Enter command was parsed
0519
Good
RW
Good rdr cmd on exit accum A reader command was parsed successfully on exit from accumulation
051A
Good
RW
Good rdr cmd on ENTER A reader command was parsed successfully when Enter was parsed
A-5
Page 194
JANUS PSK for Ada Reference Manual
Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code
Severity
Subsystem
Reader Message and Description
051C
Good
RW
Enter accum parsed An Enter Accumulate has been parsed when accumulating
051D
Good
RW
Exit multi-read A label terminating a multiple-read sequence was scanned
051E
Good
RW
Enter multi-read A label beginning a multiple-read sequence was scanned
0521
Good
RW
No comms status No communications status to report
0525
Good
RW
Rdr cmds parsed Reader commands forwarded to the application were parsed
0600
Good
CU
Comm success Communications operation success
0601
Good
CU
Comm Buff done Communications buffer done
0800
Good
PM
PM success Power management successful
0A00
Good
TM
Timer success Timer operation successful
0B00
Good
BP
Beep success Beeper call successful
0E00
Good
IM
String Extract Complete
0E01
Good
IM
String Append complete
0E02
Good
IM
Search string found
0E03
Good
IM
String Copy complete
0E04
Good
IM
Operation success Successful operation
0F00
Good
LG
Successful operation
1000
Good
KB
Expanded keypad success Expanded keyboard buffer successful
100A
Good
KB
Expanded buffer enabled
100B
Good
KB
Expanded buffer disabled
1100
Good
SS
System Config success System configuration successful
A-6
Page 195
Appendix A: Status Codes
A
Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code
Severity
Subsystem
Reader Message and Description
1200
Good
KP
Keypad success Successful keypad operation
1300
Good
DP
Display success Successful display operation
1A00
Good
EX
Execution success Transaction successful
1A01
Good
EX
ACK received Transaction successful, ACK received
1A10
Good
EX
Data received Received host message on Read operation
4200
Warning
CM
Not all config items copied Not all configuration items copied
4201
Warning
CM
Rdr Cmd terminated config cmd Reader command terminated configuration command string
4202
Warning
CM
Client should not be notified
4502
Warning
RW
Input timeout
4503
Warning
RW
No input data
450E
Warning
RW
The app should be notified The application should be notified
4529
Warning
RW
Input from source other than requested Input from source is other than the ones requested
452A
Warning
RW
RWTSR already loaded
4600
Warning
CU
Warning buff canceled Buffer canceled
4601
Warning
CU
Comm Timeout warning Communication timeout
4602
Warning
CU
Comm had no client to cancel Communication had no client to cancel
4603
Warning
CU
Comm Util no PH for config No protocol handler to configure
4604
Warning
CU
Prot handler not loaded Protocol handler is not yet loaded
4605
Warning
CU
Prot handler already receiving Protocol handler is already receiving
A-7
Page 196
JANUS PSK for Ada Reference Manual
Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code
Severity
Subsystem
Reader Message and Description
4606
Warning
CU
PH not active for link request Protocol handler is not active for link request
4A00
Warning
TM
Timer not active Timer not currently active
5001
Warning
KB
Expanded buffer installed Expanded keyboard buffer installed or disabled
5201
Warning
KP
Backdoor Comms failed Backdoor communications failure
5A02
Warning
EX
NAK received Transaction failed, NAK received
5A07
Warning
EX
No more log records Standby file is empty
5A11
Warning
EX
Received data truncated Data was truncated
5A12
Warning
EX
Fields overflow Too many fields
5A20
Warning
EX
Record logged Record stored in standby file successfully
5A21
Warning
EX
Logged but upload error Record stored in standby file, but upload standby error
8100
Error
RS
Rservice invalid request code Invalid function code received
8101
Error
RS
Rservice not installed Reader services is not installed
8102
Error
RS
Rservice resume failed Reader services resume failed
8103
Error
RS
Rservice or App out of date Reader services or application is out of date
8104
Error
RS
RWTSR not connected Reader Wedge TSR is not installed
8200
Error
CM
Invalid Object
8201
Error
CM
Invalid subfunction
8202
Error
CM
Invalid Param length Invalid parameter length
A-8
Page 197
Appendix A: Status Codes
A
Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code
Severity
Subsystem
Reader Message and Description
8203
Error
CM
Invalid Param val Invalid parameter value
8204
Error
CM
Invalid Param 1 value Invalid first parameter value
8205
Error
CM
Invalid Code 39 config Invalid Code 39 configuration (HIBC and no check digit)
8206
Error
CM
Invalid param 2 value Invalid second parameter value
8207
Error
CM
Invalid Code 39 config Invalid Code 39 configuration (HIBC and full ASCII)
8208
Error
CM
Invalid Code 39 config Invalid Code 39 configuration (HIBC and mixed full ASCII)
8209
Error
CM
Invalid Param 3 value Invalid third parameter value
820A
Error
CM
Invalid Codabar cfg Invalid Codabar configuration (ABC and discard start/stop)
820B
Error
CM
Protocol not loaded
820C
Error
CM
Invalid comm or protcl Invalid port or protocol specified
820D
Error
CM
No end quote No ending quote found
820E
Error
CM
No dbl quote No double quote (might be missing an opening quote)
820F
Error
CM
Invalid parser state
8210
Error
CM
Invalid config cmd Invalid configuration command
8211
Error
CM
Client returned err Client deemed configuration command invalid
8212
Error
CM
Invalid beep duration
8213
Error
CM
Invalid beep freq Invalid beep frequency
8214
Error
CM
Invalid beep vol Invalid beep volume
A-9
Page 198
JANUS PSK for Ada Reference Manual
Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code
Severity
Subsystem
Reader Message and Description
8215
Error
CM
Beep vol alrdy off Beep volume already off
8216
Error
CM
Beep vol alrdy on Beep volume already on
8217
Error
CM
Invalid beep specifier Invalid beep specifier (must be “L” or “H”)
8218
Error
CM
Inappropriate protcl Inappropriate configuration for the current protocol
8219
Error
CM
BIOS rejected set config BIOS rejected the set configuration command
821A
Error
CM
Bld string too small Configuration command string object is too small
821B
Error
CM
Invalid Build cmd Configuration ID is invalid
821C
Error
CM
Invalid Build param Invalid build parameter
821D
Error
CM
No Build Func No build function
821E
Error
CM
No more build entries
821F
Error
CM
No more WM bld entries No more build entries in wedge lookup table
8220
Error
CM
No more WM bld entries No more build entries in wedge lookup table for “build next” WM command
8221
Error
CM
No LUM key entries No entries found in the LUM key table
8222
Error
CM
WM entry not found No match in lookup table for specified character
8223
Error
CM
Invalid Temp config At least one parameter rejected by client (see JANUS.ERR)
8224
Error
CM
Config Item not found Configuration item is not found
8225
Error
CM
File Open err File open error
A-10
Page 199
Appendix A: Status Codes
A
Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code
Severity
Subsystem
Reader Message and Description
8226
Error
CM
File Write err File write error
8227
Error
CM
File Read err File read error
8228
Error
CM
Read record too large Record too large to read
8229
Error
CM
Invalid Hex Char in esc seq Invalid hex character found in the escape sequence
822A
Error
CM
Invalid esc sequence Invalid escape sequence
822B
Error
CM
Read file not opened Read attempted on a file that was not opened
822C
Error
CM
Write file not opened Write attempted on a file that was not opened
822D
Error
CM
File close op fail File close operation failed
822E
Error
CM
Attempt close non-open file Attempt made to close a file that was not opened
822F
Error
CM
Invalid default config Invalid default configuration
8230
Error
CM
RF back not installd RF back is not installed
8231
Error
CM
RF driver not installd RF protocol handler is not installed
8232
Error
CM
Path (IMPATH) not found Path specified by IMPATH is not found
8233
Error
CM
Bld BIOS val out of range BIOS returned an invalid value during build
8234
Error
CM
Config Item not allowed by Prot Configuration item is not allowed for the selected protocol
8235
Error
CM
Config Item value out of range Configuration item value is out of range for the selected protocol
8236
Error
CM
Invalid 4th param value Invalid fourth parameter value
A-11
Page 200
JANUS PSK for Ada Reference Manual
Status Codes and Error Messages Listed in Numerical Order (continued) Hex Code
Severity
Subsystem
Reader Message and Description
8237
Error
CM
Invalid 5th param value Invalid fifth parameter value
8238
Error
CM
Invalid 6th param value Invalid sixth parameter value
8239
Error
CM
Can’t open JANUS.ERR Unable to open JANUS.ERR file
823A
Error
CM
Radio.cfg has invalid checksum File checksum is invalid
823B
Error
CM
Invalid RF freq in RF config Invalid RF frequency specified
823C
Error
CM
Invalid RF channel in RF config Invalid channel specified
823D
Error
CM
CM_ENCODED_RF_DATA_S != CM_NUM_RF_CHANNELS Structure mismatch
823E
Error
CM
Allowed RF channels after unallowed channel Specified RF channel is not allowed
823F
Error
CM
Ping cmd not allowed here Ping command not allowed here
8240
Error
CM
Ping cmd not xmitted, prot busy Ping command not transmitted (protocol busy)
8241
Error
CM
Missing end of config cmd Missing end of configuration command
8242
Error
CM
RF freq doesn’t match RF back type RF frequency does not match the RF back
8243
Error
CM
Can’t read RF back config data Unable to read configuration data from the RF back
8244
Error
CM
Unallowed video display mode Video display mode is not allowed
8245
Error
CM
Cmd source not allowed Command source is not allowed
8246
Error
CM
Invalid 7th param value Invalid seventh parameter value
8300
Error
SC
Scanner load err Scanner load error
A-12