Page 181

nugget code39 helconitalConfiguring the Reader

Parameter

Options

Location in IC.EXE

Scroll line

8 16 25

Op menu, Display option

Character height

1x (normal) 2x (double)

Op menu, Display option

Internal Drive Reset

Do not reset card Reset card Prompt for reset

Op menu, Power Mgmt option

Key Code Look-Up Table

Keys changed No modifications

Op menu, Key Codes option

Keypad Caps Lock

Enabled Disabled

Op menu, Keypad option

Keypad Clicker

Disabled Enabled

Op menu, Keypad option

Keypad Ctrl Key Functions

Enabled Disable Ctrl-Alt-Del Disable Ctrl combinations

Op menu, Keypad option

Keypad, Numeric

Disabled Enabled

Op menu, Keypad option

Postamble

<CR> Disabled (no char.) Any 25 ASCII characters

Op menu, Amble option

Preamble

Disabled (no characters) Any 25 ASCII characters

Op menu, Amble option

Scan Ahead

Disabled Enabled

Op menu, Scanner option

Scanner Devices

All compatible scanners 1461 CCD 1500 1515 1545 Symbol scanner

Op menu, Scanner option

Scanner Mode

One-Shot mode Automatic mode

Op menu, Scanner option

Scanner Redundancy

None Normal High

Op menu, Scanner option

5

Operations Table (continued)

5-25

Page 182

JANUS 2010 Hand-Held Computer User’s Manual (4MB)

Operations Table (continued) Parameter

Options

Location in IC.EXE

Scanner Timeout

Disabled (0) 1-60 seconds

Op menu, Scanner option

Scanner Trigger

Level Edge

Op menu, Scanner option

Viewport Movement Keys

Enabled Disabled

Op menu, Keypad option

Viewport Movement Mode

Auto Manual

Op menu, Viewport option

Viewport Movement Steps

1 - 20 horizontal 10 horizontal 1 - 9 vertical 9 vertical

Op menu, Viewport option

5-26

Page 183

nugget code39 helconital

6 Networking the Reader

Page 184

nugget code39 helconital

Page 185

Networking the Reader nugget code39 helconital

6

This chapter introduces networking concepts and explains how to use COM ports, configure the reader for communications, run Interlnk, use Communications Manager, and download applications with binary file transfer (BFT).

How the JANUS 2010 Fits Into Your Network The JANUS reader is a versatile hand-held computer that you can easily add to your network or distributed data collection system. For example, you can connect your JANUS 2010 directly to another reader or computer, enabling both computers to share files, data, and programs.

Two Readers Communicating Through Their Optical Ports Reader to reader direct optical link J2010

J2010

2010U.082

Reader and PC Communicating Through Direct Cabling J2010

Optical Link Adapter

Reader to PC connection Host computer 2010U.085

6-3

Page 186

JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital

JANUS Readers in an Ethernet and CrossBar Data Collection Network Mainframe File server

CRT terminals

Ethernet 9154/9161 CrossBar Controller

JANUS Communications dock hardwired to CrossBar controller

JANUS Communications dock hardwired to CrossBar controller

PC

2010U.094

JANUS Communications dock hardwired to PC

You can make the JANUS 2010 an end device in your local area network or distributed data collection system. The reader is often used as a downline data collection computer connected to powerful upline systems.

6-4

Page 187

Networking the Reader nugget code39 helconital

6

JANUS Readers in a Radio Frequency (RF) Data Collection Network

9180 Network Controller

9181 Base Radio Unit

J2010 with an RF Back

Host computer

9183 Repeater

JR2020 (RF) 2010U.093

You can use a JANUS 2010 with an RF back as an end device in your RF network. For help, see your JANUS RF documentation.

6-5

Page 188

JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital

Working With JANUS COM Ports Communications ports, also called COM ports, are locations from which data can be passed into and out of the reader. COM ports offer serial communications, which means that data is transmitted one bit at a time over a single line from one computer to another. The next sections cover these topics: •

Identifying JANUS COM Ports

•

Examining the COM1 Optical Port Signals

•

Understanding How IRQs Affect COM Ports

•

Designating the Scanner Port as COM2

Identifying JANUS COM Ports This illustration identifies the COM ports on the reader, and the table explains how each is designated as a COM port. Logical COM4

I /O

TM

F1

~

+, –

A

> <

I

G

Z

S me

&

+ pg

Esc

$ up

/

* te en @

4 d en

!

6

^ pg

* % 5r, –

A m

3 dn

# l de

\

Ctrl

T Z Y

.

me ho

X f Cap s Esc

Alt

U

S r nte

/

W V

O

M

R

Q

P

N

&

+ pg

$ up

*

/ en te en @

!

6

^ pg

* % 5r

4 d

9

(

8

7 –

0 ins

1 m lock nu

# l de ter en

3 dn

2

>

.

0 ace ace sp sp

COM4 External PC card drive containing a modem card J2010 with a PCMCIA Back

> <

I

?

K

J

H e >

L ]

[

C

B

E

D

–– lock nu

2 ins

1

+

F

}

{

G

9

(

F2

F1

~

8

7 –

F6 s

Alt Ctrl ho

F7 f Cap

T

Y

X

W

U \

M

/

V

N

F3

F8

R

Q

P

O

H

?

K

J

[

––

B

]

F4

F9

L

E

D

C

I /O

F5

0

F1

F

}

{

(

F6

F2

TM

F5

0

F1 F4

F9 F3

F8 F7

(

COM2 Scanner port

J2010 with an RF Back COM1 Optical port

2010U.087

Port

How Is it Designated as a COM Port?

COM1

By default.

COM2

Use IC.EXE or scan two Communications Port configuration commands: Scanner or COM2 (IX), and UART Restore (IW).

COM4

Use the modem card’s configuration tool.

Logical COM4

By default in JANUS 2010 with RF back.

Note: Intermec recommends that you do not designate any COM port as COM3. For details, see “Understanding How IRQs Affect COM Ports” later in this chapter.

6-6

Page 189

Networking the Reader nugget code39 helconital

6

Examining the COM1 Optical Port Signals The reader’s COM1 is an optical serial port. You can communicate through COM1 using a communications dock, optical link adapter, or another reader. This illustration shows the optical port’s signals:

c me er Int

COM 1 Optical port

Request to Send Clear to Send Port Select Receive Data Transmit Data

2010U.183

Understanding How IRQs Affect COM Ports According to the industry standard architecture (ISA) for PCs, the COM ports on a PC must share hardware interrupt requests (IRQs). Because your JANUS reader is PC compatible, the reader’s COM ports also share IRQs: IRQ3 is assigned to both COM2 and COM4. IRQ4 is assigned to both COM1 and COM3. The ISA practice of sharing IRQs causes limitations on the JANUS readers: •

The Intermec protocol handlers, PHIMEC and PHPCSTD, cannot share IRQs. You can load PHIMEC or PHPCSTD only on COM1.

•

The Intermec RF protocol handler (RFPH) uses “logical COM ports.” RFPH designates the RF port as “logical COM4” but does not use IRQ3. Instead, IRL uses the logical port numbers to direct transmits and receives. For example, X4P transmits using “logical COM4.”

•

Intermec recommends that you do not designate any JANUS port as COM3. Because COM1 and COM3 share an IRQ, you cannot use COM1 if you use COM3.

•

You may experience an IRQ conflict if you use COM2 and COM4 at the same time, because the two ports share IRQ3. Whether you experience a conflict depends on the third-party software you use on COM2 and COM4.

6-7

Page 190

JANUS 2010 Hand-Held Computer User’s Manual (4MB) nugget code39 helconital Designating the Scanner Port as COM2 If you do not need to connect a scanner to the JANUS 2010, you can designate the scanner port as COM2 and take advantage of another communications port. The scanner port is a modular connector on the top of the reader.

Scanner port or COM2

2010U.171

You must use the COM2 Hardware Adapter (Part No. 061799) to use the scanner port as COM2. For details, see the COM2 Adapter Quick Reference Guide. You can designate the scanner port as COM2 with these two commands, which are described in Chapter 12: • •

Communications Port, UART Restore Communications Port, Choose Scanner or COM2

You can also use IC.EXE to designate the scanner port as COM2 by following these steps: 1. Start IC.EXE and choose COM2 from the COM menu. The Configuration COM2 screen appears. Configuration COM2

SCANNER/COM2 SELECT: Scanner FIFO CONTROL REGISTER (hex):00 OK

Cancel

2010U.172

2. Set the SCANNER/COM2 SELECT parameter to COM2. 3. Exit IC.EXE. When prompted, save the changes to the online configuration. For help using IC.EXE, see Chapter 5, “Configuring the Reader.”

6-8