For the Intermec J2010

Page 171

nugget code39 helconitalConfiguring the Reader

5

If the configuration file contains errors, the reader displays a message stating that the reader configuration is unchanged. The reader generates an error file with the same filename as the configuration file, but with the extension .ERR. This file lists the line numbers with the incorrect syntax and the reason for the error. The command SET IM_ERRPATH=E:\ in AUTOEXEC.BAT specifies that the error file is written to drive E. You can view the file by typing this command at the DOS prompt on drive E: type filename.err

Loading a Configuration File Whenever You Boot Each time you cold boot the reader, the reader returns to its default configuration. If you do not want the default configuration, you can add a command to AUTOEXEC.BAT that configures the reader with another configuration file every time you warm or cold boot the reader. The reader’s AUTOEXEC.BAT file is stored on drive C. Because drive C is a ROM drive resident in flash memory, you must use special utilities to change its contents. For help, see “Learning How to Change the Contents of Drive C” in Chapter 3. To load a configuration file when you boot the reader 1. Create the configuration file to load when you boot the reader. For example, to save the current configuration in a file, start IC.EXE and select Save As from the File menu. Type a unique DOS filename for the file, such as JANUS.INI. 2. Add this line to the reader’s AUTOEXEC.BAT file: d:\ic /l path\filename where: /l loads the configuration file.

path is the drive and directory that contains the configuration file.

filename is the name of the configuration file you want to load.

For example, type this command: d:\ic /l e:\network\reader\janus.ini

5-15

Page 172

JANUS 2010 Hand-Held Computer User’s Manual (4MB)

3. Copy the configuration file and new AUTOEXEC.BAT onto drive C. Or copy the configuration file onto a memory card in one of the PC card drives. Because the reader cannot boot from drive F, you should not copy the new AUTOEXEC.BAT file to drive F and expect the reader to boot from drive F. Note: If you store the configuration file on drive E, the file will be erased when you cold boot the reader, load flash memory, put the reader in Storage mode, or execute CONFIG.SYS after changing the command that creates drive E.

Restoring the Reader’s Default Configuration When you configure the reader according to the instructions presented in this chapter, the parameters remain in effect until you reconfigure the parameters or cold boot the reader. You can return the reader to its default configuration, which is described in Appendix A. Choose one of these methods: •

Type this command at the DOS prompt and press

@:

ic /d

Or scan this command at the DOS prompt:

*IC /OD* *IC /D*

•

Use IC.EXE to restore the default configuration. At the DOS prompt, type ic and press . Choose the Load Default command from the File menu. Then choose Exit from the File menu. When prompted to update the online configuration, choose Yes.

•

Cold boot the reader. During a cold boot, the reader returns to its default configuration. For help, see “Cold Booting the Reader” in Chapter 9.

@

Note: The reader does not return to its default configuration during a cold boot if you followed the instructions in the previous section, “Loading a Configuration File Whenever You Boot.”

Recording Your Reader’s Configuration These tables list all of the configuration parameters, their options, and where to find them in IC.EXE. The default setting for each parameter is identified in bold italics in these tables.

5-16

Page 173

nugget code39 helconitalConfiguring the Reader

5

You should have an accurate record of the reader’s configuration settings in case the reader is ever reset and the configuration setup is lost: •

You can back up the reader’s configuration files and store the backups on another reader, a host computer, a PC card, or a disk.

•

You can record the configuration on the following pages by circling the option you chose for each parameter or writing the value.

Bar Code Symbologies Table Parameter

Options

Location in IC.EXE

Codabar

Disabled ABC Standard

Sym menu, Codabar option

Start/Stop

Concatenated Discard Retain ABCD Retain DC1-DC4

Sym menu, Codabar option

Code 11

Disabled One check digit Two check digits

Sym menu, Code 11 option

Code 16K

Disabled Standard With function code 1

Sym menu, Code 16K option

Code 2 of 5

Disabled 3 bar start/stop, label length 2 bar start/stop, label length

Sym menu, 2 of 5, I2 of 5 option

Code 39

Disabled No check digit Check digit HIBC AIAG check digit

Sym menu, Code 39 option

Check digit

Discard Retain

Sym menu, Code 39 option

ASCII

Non-full ASCII Full ASCII Mixed-full ASCII

Sym menu, Code 39 option

Code 49

Disabled Enabled

Sym menu, Code 49 option

Function Code 1

Disabled ASCII character

Sym menu, Code 49 option

5-17

Page 174

JANUS 2010 Hand-Held Computer User’s Manual (4MB)

Bar Code Symbologies Table (continued) Parameter

Options

Location in IC.EXE

Function Code 2

Disabled ASCII character CR LF

Sym menu, Code 49 option

Function Code 3

Disabled ASCII character

Sym menu, Code 49 option

Code 93

Disabled Enabled

Sym menu, Code 93 option

Code 128

Disabled Standard UCC/EAN-128

Sym menu, Code 128 option

Interleaved 2 of 5

Disabled Fixed length # Variable length, no check digit Case Code, check digit Variable length, check digit

Sym menu, 2 of 5, I2 of 5 option

MSI

Disabled No check digit 1 modulus 10 check digit 2 modulus 10 check digits

Sym menu, MSI option

Check digits

Discard Retain

Sym menu, MSI option

Plessey

Disabled Discard check digit Retain check digit

Sym menu, Plessey option Sym menu, UPC/EAN option

UPC/EAN Check digit

Discard Retain

Sym menu, UPC/EAN option

EAN-8

Disabled Enabled

Sym menu, UPC/EAN option

Supplementals

Yes No

Sym menu, UPC/EAN option

UPC-A/EAN-13

Disabled Enabled UPC-A only

Sym menu, UPC/EAN option

UPC-E

Disabled Enabled

Sym menu, UPC/EAN option

Number system digit

Discard Retain

Sym menu, UPC/EAN option

UPC-A leading zero

Discard Retain

Sym menu, UPC/EAN option

5-18

Page 175

nugget code39 helconitalConfiguring the Reader

5

Communications Table Parameter

Options

Location in IC.EXE

Communications Dock Port

Auxiliary Network

Com menu, COM1 or COM2 option, Dock Port option

COM Port, Select

COM1 COM4

Not available in IC.EXE

COM Port, UART Restore

00 Hex Hex value

Com menu, COM1 or COM2 option UART Restore option

Communications Protocol Configure

User-Defined Point-to-Point Polling Mode D Multi-Drop PC Standard

Com menu, COM1 or COM2 option, Configure option

Communications Protocol, Activate

User-Defined Point-to-Point Polling Mode D Multi-Drop PC Standard None

Com menu, COM1 or RF option, Activate option

Communications Protocol, User-Defined Multi-Drop

Disabled Enabled

Com menu, Configure option, User-Defined protocol

5-19

Page 176

JANUS 2010 Hand-Held Computer User’s Manual (4MB)

Communications Protocol Parameters Table Parameter

Options

Location in IC.EXE

Address, Multi-Drop

A to Z, 0 to 5 A

Com menu, COM1 or COM2 option, Multi-Drop protocol

AFF

Disabled Any ASCII character

Com menu, COM1 or COM2 option, User-Defined protocol

Baud Rate

110 300 600 1200 2400 4800 9600 19200 38400

Com menu, COM1 or COM2 option, All protocols except Multi-Drop

Data Bits

7 bits 8 bits

Com menu, COM1 or COM2 option, All protocols except Polling Mode D

EOF

Disabled Any ASCII character

Com menu, COM1 or COM2 option, User-Defined protocol

EOM Transmit

Disabled Any two ASCII characters CR and LF

Com menu, COM1 or COM2 option, User-Defined protocol

EOM Receive

Disabled Any two ASCII characters CR and LF

Com menu, COM1 or COM2 option, User-Defined protocol

EOR

Disabled Any two ASCII characters

Com menu, COM1 or COM2 option, User-Defined protocol

Flow Control

None XON/XOFF response XON/XOFF control XON/XOFF response and control CTS checking/RTS control

Com menu, COM1 or COM2 option, User-Defined protocol Point-to-Point protocol Polling Mode D protocol

5-20

Page 177

nugget code39 helconitalConfiguring the Reader

5

Communications Protocol Parameters Table (continued) Parameter

Options

Location in IC.EXE

Intercharacter Delay

0 1 ms 2 ms 5 ms 10 ms 20 ms 50 ms 100 ms

Com menu, COM1 or COM2 option, User-Defined protocol Point-to-Point protocol

IRL BAK

Disabled Any ASCII character BEL

Com menu, COM1 or COM2 option, User-Defined protocol

IRL End Program Block

Disabled Any ASCII character SO (shift out)

Com menu, COM1 or COM2 option, User-Defined protocol

IRL EOP

Disabled Any ASCII character SYN (synchronous idle)

Com menu, COM1 or COM2 option, User-Defined protocol

IRL PAK

Disabled Any ASCII character RS (record separator)

Com menu, COM1 or COM2 option, User-Defined protocol

IRL PSS

Disabled Any ASCII character CR (carriage return)

Com menu, COM1 or COM2 option, User-Defined protocol

IRL RUN

Disabled Any ASCII character DC2 (device control 2)

Com menu, COM1 or COM2 option, User-Defined protocol

IRL SOP

Disabled Any ASCII character SI (shift in)

Com menu, COM1 or COM2 option, User-Defined protocol

LRC

Disabled Enabled

Com menu, COM1 or COM2 option, User-Defined protocol

NEG

Disabled Any ASCII character

Com menu, COM1 or COM2 option, User-Defined protocol

Parity

None Even Odd Mark Space

Com menu, COM1 or COM2 option, All protocols except Polling Mode D

5-21

Page 178

JANUS 2010 Hand-Held Computer User’s Manual (4MB)

Communications Protocol Parameters Table (continued) Parameter

Options

Location in IC.EXE

POL

Disabled Any ASCII character

Com menu, COM1 or COM2 option, User-Defined protocol

Records Per Block

All records transmitted in one block 1-99 records transmitted per block

Com menu, COM1 or COM2 option, User-Defined protocol

REQ

Disabled Any ASCII character

Com menu, COM1 or COM2 option, User-Defined protocol

RES

Disabled Any ASCII character

Com menu, COM1 or COM2 option, User-Defined protocol

SEL

Disabled Any ASCII character

Com menu, COM1 or COM2 option, User-Defined protocol

SOM

Disabled Any ASCII character

Com menu, COM1 or COM2 option, User-Defined protocol

Stop Bits

1 bit 2 bits

Com menu, COM1 or COM2 option, User-Defined protocol Polling Mode D protocol PC Standard protocol

Timeout Delay

5 ms 100 ms 500 ms 2 sec 10 sec 20 sec 40 sec 60 sec no timeout

Com menu, COM1 or COM2 option, User-Defined protocol Point-to-Point protocol

Transmit Abort Timeout

Disabled (0) 1-65000 ms

Com menu, COM1 or COM2 option, User-Defined protocol Multi-Drop protocol

5-22

Page 179

nugget code39 helconitalConfiguring the Reader

5

Communications Protocol Parameters Table (continued) Parameter

Options

Location in IC.EXE

Turnaround Delay

0 1 ms 2 ms 5 ms 10 ms 20 ms 50 ms 100 ms

Com menu, COM1 or COM2 option, User-Defined protocol Point-to-Point protocol

Parameter

Options

Location in IC.EXE

Automatic Shutoff

Disabled (0) 15 sec 1 minute 1 - 60 minutes

Op menu, Power Mgmt option

Beep Duration

1 ms to 60,000 ms High beep 50 ms Low beep 50 ms

Op menu, Beeper option

Beep Frequency

20 to 20,000 Hz High beep 2000 Hz Low beep 1000 Hz

Op menu, Beeper option

Beep Volume

Off Quiet Normal Loud Very loud

Op menu, Beeper option

Command Processing

Disable all reader commands Enable all reader commands Enable override Disable override

Op menu, Reader Commands option

Enable/Disable specific commands

Abort program (IRL) Backlight Backspace Change Configuration Clear Clear File (IRL) Cursor to Viewport Download Program (IRL) End Change Configuration Enter Enter Accumulate mode

Op menu, Reader Commands option, Enable option

Operations Table

5-23

Page 180

JANUS 2010 Hand-Held Computer User’s Manual (4MB)

Operations Table (continued) Parameter

Options

Enable/Disable specific commands (continued)

Enter Key Code Exit Accumulate mode IRL Program Resume Laser Off Laser On Multiple-Read Labels Prepare for Reboot Reboot Receive File (IRL) Run Program (IRL) Set Clock Transmit File (IRL) Viewport to Cursor Viewport Down Viewport End Viewport Home Viewport Left Viewport Page Down Viewport Page Up Viewport Right Viewport Up

Decode Security

Low Moderate High

Op menu, Scanner option

Display Backlight Timeout

Disabled (0) 1 - 60 seconds 10 seconds

Op menu, Display option

Display Contrast

0-7 3

Op menu, Display option

Display Mode, IRL

Buffered Transparent

Op menu, IRL option

Display Setup

25 x 80 16 x 20 8 x 20 16 x 10 8 x 10

Op menu, Display option

Video mode

0 1 2 3

Op menu, Display option

5-24

Location in IC.EXE