Page 29

A Specifications This appendix includes physical and electrical specifications for the IP4.

19

Page 30

Appendix A, Specifications

IP4 Specifications Environmental Specifications Specification

Value

Operating temperature

-20°C to 55°C (-4°F to 1°F)

Storage temperature

-30°C to 70°C (-22°F to 158°F)

Relative humidity

5 to 95% non-condensing

865 MHz Frequency Specification

Value

Source type

4 channel selectable

Frequency band

865-868-MHz

Output power 0.5 W maximum

Minimum = 26.0 dBm Typical = 26.5 dBm Maximum = 27.0 dBm

869 MHz Frequency Specification

Value

Source type

Single Channel

Frequency band

869.525 MHz

EIRP/ERP

0.5 watt ERP

Output power 0.5 W maximum

Minimum = 26.0 dBm Typical = 26.5 dBm Maximum = 27.0 dBm

915 MHz Frequency Specification

20

Value

Source type

Frequency hopper

Frequency band

902-928 MHz

IP4 Portable RFID Reader User’s Guide

Page 31

Appendix A, Specifications

915 MHz Frequency Specification

Value

EIRP/ERP

1 watt EIRP

Output power

Minimum = 28.5 dBm

1 W maximum

Typical = 29.5 dBm Maximum = 30.0 dBm

Performance Specification

Value

RFID tag identification rate

At least six tags per second with one to ten tags in the RF field, located at half the maximum reading distances from the IP4 front panel.

RFID tag read distance

91 cm (3 ft)

RFID tag data exchange rates

Read a tag containing 8 bytes of data within 50 ms. Perform a verified write to tag at an average rate of 75 ms per byte per tag.

Firmware Architecture Specification

Value

Firmware

Communicates in Basic Reader Interface (BRI) mode.

Protocol/Compatibility ANSI NCITS 256.2000 for API, part 2, part 3-1

IP4 Portable RFID Reader User’s Guide

21

Page 32

Appendix A, Specifications

Reader Configuration Access Summary

22

Function

Control

Responsible Party

Change Country Code

Hardware key or configuration tag

Factory or Intermec Field Technician

Download Intermec-only updated firmware password

Remote or on-site field technician

Setup, system Configuration file configuration not secured at higher level, such as change battery or wake up default

Customer System Administrator

IP4 Portable RFID Reader User’s Guide

Page 33

This page is a scan with no text; see it in the PDF.

Page 34

Worldwide Headquarters 6001 36th Avenue West Everett, Washington 98203 U.S.A. tel 425.348.2600 fax 425.355.9551 www.intermec.com © 2008 Intermec Technologies Corporation. All rights reserved.

IP4 Portable RFID Reader User’s Guide

*943-002-005* P/N 943-002-005