Page 161

Connecting to the 9180 and the Intermec CrossBar Network

7

Setting the Time Parameters Use this dialog box to configure the time broadcast and time append parameters. If the Intermec controller does not support one of the parameters, it is grayed out. Broadcast Parameters These optional parameters broadcast a time, with a short string, at certain intervals from the Intermec controller to all devices connected to it. These parameters synchronize the devices with the controller. Note: Using 0 to disable time broadcast is not supported on the 9180 controller. Append Parameters These optional parameters configure the Intermec controllers to stamp the time at certain intervals to incoming data. The timestamp is in the format: HH:MM:SS

If you want all messages to have a timestamp with the hour and minute, enable this feature and set the interval to 0. Depending on your controller, you can also append the seconds. If no data is available within the interval, the controller waits until it receives data and then appends the time before sending it to the host. This feature will not operate when running terminal emulation or using the direct TCP/IP socket interface. Note: Do not enable time append on both the Intermec controller and the device itself. If it is enabled on both, two timestamps are appended to incoming data. Note: If you are configuring a 9161 controller, you need to set the internal DIP switches to enable the time append feature. You can use this dialog box to set the interval of the time append.

7-15

Page 162

DCS 300 User’s Manual

To set the time parameters •

7-16

From any Configure Controller dialog box, choose Time Parameters. The Configure Time Parameters dialog box appears.

Page 163

Connecting to the 9180 and the Intermec CrossBar Network

Field

Description

Value

Default

Broadcast enabled

This check box determines if the Intermec controller broadcasts time to its devices.

Check, Clear

Clear

Include Seconds (9180 only)

This check box adds seconds to the time.

Check, Clear

Clear

Include Date (9154/9180 only)

This check box adds the date to the time.

Check, Clear

Clear

Interval

This field specifies how often the controller broadcasts the time. If you set this field to 0, no time broadcast is made.

0 to 99 minutes

1

Preamble (9154/9180 only)

This field lets you add a short message to the beginning of the time.

1 to 5 alphanumeric characters

None

Postamble (9154/9180 only)

This field lets you add a short message to the end of the time.

1 to 5 alphanumeric characters

None

Time format (9154/9180 only)

These option buttons choose the time broadcast format.

12 hour, 24 hour

12 hour

Append enabled

This check box determines if a timestamp is added to messages from devices.

Check, Clear

Clear

7

Note: Intermec recommends that you use the time append feature. If you do not, you may see a “protocol error occurred” message in the error log. Include Seconds (9180 only)

This check box adds a 2-digit seconds to the time.

Check, Clear

Clear

Record day rollover (9154/9180 only)

This check box adds a timestamp in the buffer of the host at midnight.

Check, Clear

Clear

Interval

This field specifies how often in minutes the controller appends the timestamp. If you set this field to 0, every message from a device will have a timestamp.

0 to 99

1

7-17

Page 164

DCS 300 User’s Manual

Defining Default Hosts (9180 v2.0) You can configure a default host for each of the types of hosts the 9180 devices will communicate with through the 9180 v2.0 controller. You can configure the devices to • explicitly link with a specific host. Click the down arrow on the right side of the field and choose a host that you have configured.

• prompt the user to enter a host name. Click the down arrow on the right side of the field and choose <Prompt>.

• not communicate with a host. Click the down arrow on the right side of the field and choose <none>.

To configure a specific device to communicate in a different way to a host, see “Configuring TE Links” in Chapter 8. To configure your link •

From the Configure Controller: 9180 v2.0 dialog box, choose Default Host Links. The 9180 v2.0 Default Host Links dialog box appears.

Field

Description

Value

Default

3270 SNA

The method that the RF card devices will use to get a host name when they communicate with 3270 SNA hosts.

None, Prompt, pre-defined list

Prompt

5250 SNA

The method that the RF card devices will use to get a host name when they communicate with 5250 SNA hosts.

None, Prompt, pre-defined list

Prompt

Telnet (all)

The method that the RF card devices will use to get a host name when they communicate with Telnet hosts.

None, Prompt, pre-defined list

Prompt

7-18

Page 165

Connecting to the 9180 and the Intermec CrossBar Network

7

Defining the 9180 v2.0 Devices When you choose OK in the Configure Controller: 9180 v2.0 dialog box, this dialog box appears.

Field

Description

Value

Default

Base logical name

The base name that the server uses to create a unique logical name for each device. The server appends a sequential 3-digit number to this name for each device.

1 to 13 alphanumeric characters

COM1

Number of terminals to enable

The number of logical names that you want the server to generate.

1 to 128

8

7-19

Page 166

DCS 300 User’s Manual

Identifying the CrossBar Devices The DCS 300 needs to know the addresses of all the devices that use it to communicate with the host. This section explains how to configure the server for the CrossBar devices. The device list is automatically populated with device addresses as you configure the Intermec controllers. The first eight addresses are enabled and are configured as J2020s. You need to change the device type for these addresses and enable the addresses of the other devices that you want to communicate with the host. You can also edit the individual parameters for each address. Note: Do not enable devices that you are not using. If you try to send data to a nonexistent but enabled device, your system performance will degrade. Your server has a terminal license that allows it to communicate with a limited number of device addresses (1-8, 1-24, 1-64, 1-128). The server does not keep track of the number of devices you enable. You can enable all 128 devices. As each device sends messages to the server, the server logs its address. When the server logs the maximum number of addresses that your terminal license allows, it will not accept messages from any new addresses. If you need to upgrade your terminal license, contact your local Intermec representative. To identify CrossBar devices 1. From the main menu, choose the type of communication you are using to connect the server to the host. 2. Choose Downline Network. Two buttons, Connection Points and Downline Devices, appear. 3. Choose Downline Devices. The Device List dialog box appears. 4. In the Connection field, click the down arrow on the right side of the field. A list of the controllers that are configured appears.

7-20

Page 167

Connecting to the 9180 and the Intermec CrossBar Network

7

Device List Dialog Box

5. Select the controller whose downline devices you want to configure. The Device List displays the status, address, and logical name of all 128 devices. 6. To enable all 128 devices, choose Enable All. Or, to enable specific devices, select the device you want to enable and make sure there is a check in the Enabled check box. 7. To disable all 128 devices, choose Disable All. Or, to disable specific devices, select the device you want to disable and make sure there is no check in the Enabled check box. 8. Select a device whose individual parameters you want to edit and then choose Edit Device. For help, see “Editing a CrossBar Device” in the next section. 9. Choose OK to save your changes and return to the main menu.

7-21

Page 168

DCS 300 User’s Manual

Editing a CrossBar Device •

From the Device List dialog box, choose Edit Device. The Device Parameters dialog box appears. Note: If you are using VT or ANSI terminal emulation, do not configure transaction IDs or delivery responses.

Field

Description

Value

Default

Logical name

The logical name of this device.

1 to 16 alphanumeric characters

Intermec standard

Able to receive data

This check box determines if this device can receive data from the network.

Check, Clear

If the device has a screen, it is checked, else it is cleared.

Device type

This list box contains all the current Intermec devices supported by the server.

Predefined

J2020

Physical address

This read-only field displays the physical address of the device.

Read-only

Predefined

7-22

Page 169

Connecting to the 9180 and the Intermec CrossBar Network

Field

Description

Value

Default

Auto-insert from device

This field adds a transaction ID to devices that cannot put a transaction ID in the transactions they send.

Predefined list

None

7

Note: All transactions from this terminal will be routed using this transaction ID. To be routed to device

This field contains the transaction ID that will always be routed to this device.

Predefined list

None

Interactive response (Optional)

The message that is sent to the source of the transaction if the transaction for this device is delivered successfully in Interactive mode.

1 to 39 characters

None

Hot standby (Optional)

The message that is sent to the source of the transaction if the transaction for this device is not delivered.

1 to 40 characters

None

Saving Your Run-Time Configuration When you finish configuring your downline network, you should save your changes. To save your run-time configuration •

From the main menu sidebar buttons, choose Save Configuration.

7-23

Page 170

DCS 300 User’s Manual