4 Troubleshooting and Maintaining the CN4

If you encounter any problems while using the CN4, look in this chapter to find a possible solution. You will also find information on routine maintenance. This chapter contains these sections: •

Calling Product Support

•

Troubleshooting the CN4

•

Resetting the CN4

•

Cleaning the CN4

87

Page 100

Chapter 4, Troubleshooting and Maintaining the CN4

Calling Product Support If you cannot find the answer to your problem in the Troubleshooting the CN4 section, you can visit the Intermec technical knowledge base (Knowledge Central) at intermec.custhelp.com to review technical information or to request technical support. If you still need help after visiting Knowledge Central, you may need to call Product Support. To talk to an Intermec Product Support representative, call: 1-800-755-5505 Before you call Intermec Product Support, make sure you have the following information ready: •

Configuration number

•

Serial number

•

Operating system version

•

SmartSystems Platform Bundle (SSPB) version

•

Power management settings

•

If you are using security, know the type (Funk or Microsoft) and the full set of parameters

•

If you are using terminal emulation (TE), know the version and protocol. If you are not using TE, know the language your custom application was written in and the tools you used to create it.

You can find most of the information listed above in Intermec Settings. Consult your application developer for information on your custom application. To find your configuration number •

88

Look at the label on the back of the computer.

CN4 Mobile Computer User’s Manual

Page 101

Chapter 4, Troubleshooting and Maintaining the CN4

To find your operating system version 1 Tap Start > Internet Explorer. 2 Tap the Intermec logo. The Intermec page appears and displays the software build information.

Troubleshooting the CN4 If you send the CN4 in for service, it is your responsibility to save the computer data and configuration. Intermec is responsible only for ensuring that the hardware matches the original configuration when repairing or replacing the computer. Problems While Configuring the CN4 Problem

Solution

You scan a configuration command, such as Beeper Volume, and you hear three low beeps.

If you are working in Intermec Settings, you cannot scan configuration commands. Exit the application to scan configuration commands.

You scan or enter an option for the Scanner Model configuration command and you hear three low beeps.

You may have scanned or entered a Scanner Model command that does not apply to the type of scanner that you have installed. Try scanning or entering the Scanner Model command again and select an option for the type of device you are using.

You cannot type a character on the You may have locked a modifier key on the keypad. Press keypad or you can only type uppercase the necessary key sequence to unlock the key. For help, or lowercase letters. see “Using the Keypad” on page 12.

CN4 Mobile Computer User’s Manual

89

Page 102

Chapter 4, Troubleshooting and Maintaining the CN4

Problems While Operating the CN4 Problem

Solution

You press the Power button and nothing happens.

• Make sure the backlight is on. • Make sure you have a charged battery that is installed correctly. For help, see “Charging the Battery” on page 4. • Replace the battery with a charged battery. For help, see “Changing the Battery” on page 4. • Perform a warm boot or a cold boot. For help, see “Resetting the CN4” on page 97.

The Battery status LED is on.

The battery status LED indicates the following states: • If the battery status LED is a steady green, the battery is more than 95% charged and computer is on a charger. • If the battery status LED is blinking red, then the battery is low. Replace or charge the battery. • If the battery status LED is a steady red, the main battery is on charge. • If the battery status LED is amber, the CN4 is on charge and either the battery temperature is outside of the charging range, or the battery is defective.

The computer appears to be locked up • Press the power key to turn off the computer, then and you cannot enter data. press the power key again to turn it on. • Press and hold the power key ten seconds to warm boot the computer. • Try reloading the firmware. See “Freeing Up Virtual Memory for Applications” on page 80. • If the computer does not boot or reset, contact your Intermec representative for help. You tap the screen and nothing happens.

Align your screen. For help, see “Aligning the Touch Screen” on page 21.

Problems With 802.11 Network Connectivity Problem

Solution

When you turn on the computer after it Host may have deactivated or lost current terminal emulation session. In a TCP/IP direct connect network, was suspended for a while (10 to 15 turn off the “Keep Alive” message from host to maintain minutes or longer), it can no longer the TCP session while the computer is suspended. send or receive messages over the network.

90

CN4 Mobile Computer User’s Manual

Page 103

Chapter 4, Troubleshooting and Maintaining the CN4

Problems With 802.11 Network Connectivity (continued) Problem

Solution

The CN4 is connected to the network Move closer to an access point or to a different location to reestablish communications until you reconnect with and you move to a new site to collect data. Your CN4 now shows you are not the network. Any data collected while out of range is transmitted over the network. connected to the network. There may be a problem with the host computer, with The CN4 appears to be connected to the network, but you cannot establish a the connection between the Intermec Application Server and the host computer, or with the connection between terminal emulation session with the the access point and the host computer. Check with host computer. network administrator to make sure the host is running and allowing users to login to the system. In a TCP/IP network, there may be a problem with the The CN4 appears to be connected to the network, but the host computer is connection between the access point and the host not receiving any information from the computer. Check with network administrator or use your access point user’s manual. CN4.

Problems While Configuring 802.1x Security Problem

Solution

The CN4 indicates that it is authenticated, but it does not communicate with the host.

Make sure the CN4 IP address, host IP address, subnet mask, default router are configured for network.

The CN4 may not be communicating with the access The CN4 does not appear to be point. Make sure the CN4 network name matches the authenticating and a network connection icon does not appear on the access point network name (SSID). toolbar. 802.1x security network may not be active. Make sure the server software is properly loaded and configured on the server PC. See server software documentation for help. A network connection icon appears in the toolbar, but then disappears.

The CN4 may not be communicating with the intended access point. Make sure the CN4 network name matches the access point network name. Default network name is “INTERMEC.” Access point may not be communicating with server. Ensure the access point is turned on, properly configured, and has 802.1x security enabled

You are setting up multiple access points in a network, with different SSIDs, and the connection fails.

The CN4 does not save WEP key values when changing the SSID. Reenter the WEP key value after changing the SSID and save your changes. You should now be able to connect to the different access points.

CN4 Mobile Computer User’s Manual

91

Page 104

Chapter 4, Troubleshooting and Maintaining the CN4

Problems While Configuring 802.1x Security (continued) Problem

Solution

The CN4 indicates it is not authenticated.

Make sure that: • the User Name and Password parameters on the CN4 must match the user name and password on authentication server. You may need to reenter the password on both the CN4, authentication server. • on your authentication server, the user and group are allowed and the group policy is allowed to log into the server. For help, see the documentation that shipped with your authentication server software. • the IP address and secret key for access point must match the IP address and secret key on the authentication server. You may need to reenter the IP address and secret key on both your access point and authentication server. • the authentication server software is running on the server PC.

You receive a message saying “The server certificate has expired or your system date is incorrect” after you perform a clean boot on the CN4.

Date and time are not saved when you perform a clean boot. Reenter the date and time, and then save your changes.

Problems Reading Bar Codes Problem

Solution

You cannot see a red beam of light from • the imager when you press the Scan button and aim the imager at a bar • code label.

You may be too far away from the bar code label. Try moving closer to the bar code label and scan it again. You may be reading the bar code label “straight on.” Change the reading angle and try again. • The imager hardware trigger might be disabled in Intermec Settings. To check the setting go to Start > Settings > System Tab > Data Collection > Scanner Settings. Hardware trigger should be checked.

The input device attached to the computer does not work well or read bar code labels very quickly.

92

Set the Scanner Model command to the specific attached input device. Check enabled bar code symbologies and enable only the symbologies being used.

CN4 Mobile Computer User’s Manual

Page 105

Chapter 4, Troubleshooting and Maintaining the CN4

Problems Reading Bar Codes (continued) Problem

Solution

When you release a Scan button or handle trigger, the Good Read light does not turn off.

The Good Read light will remain on if you configure the computer to use continuous/edge triggering. If you configure the computer for level triggering and the Good Read light remains on, there may be a problem. Press one of the Scan buttons or pull the trigger again without scanning a bar code label. If the light is still on, contact your local Intermec representative.

The scanner will not read the bar code label.

• Aim the scanner beam to cross entire bar code label in one pass. Vary the scanning angle. • Check the quality of the bar code label, Scan a bar code label that you know will scan. Compare the two bar code labels to see if the bar code quality is too low. You may need to replace the label that you cannot scan. • Make sure the bar code symbology is enabled and configured correctly. Use Intermec Settings to check the symbologies. Expand Data Collection > Symbologies beneath devices listed (scanner, virtual wedge) to check and enable symbologies, then scan the bar code label again. • Make sure the computer application is expecting input from a bar code. You may need to type this information instead.

The scanner does not read the bar code The scanner window may be dirty. Clean the window labels quickly, or the scanning beam with a solution of ammonia and water. Wipe dry. Do not seems to be faint or obscured. allow abrasive material to touch the window. You scan a valid bar code label to enter The computer may have decoded the bar code label in a symbology other than the label’s actual symbology. Try data for your application. The data decoded by the scan module does not scanning the bar code label again. Make sure you scan match the data encoded in the bar code the entire label. label.

CN4 Mobile Computer User’s Manual

93

Page 106

Chapter 4, Troubleshooting and Maintaining the CN4

Checking 802.11 Network Status If you have trouble connecting to your 802.11 wireless network: •

Make sure you have correctly set network parameters on the CN4.

•

Check your wireless security settings.

Follow the next procedure to use iConnect to verify available access points and networks, check signal strength, and view other diagnostics. If you need to contact Intermec Product Support, this information can be helpful in troubleshooting wireless network connection issues. To use iConnect to verify network status 1 Tap the iConnect icon ( screen.

) in the lower right corner of the CN4

2 Choose Status > Wireless. 3 Tap Advanced. The diagnostics screen appears.

The ISpy tab shows:

94

•

MAC address and IP address of the 802.11 radio.

• network association status, including the SSID and MAC address of the access point

• security configuration.

• radio transmit power and signal strength information.

CN4 Mobile Computer User’s Manual

Page 107

Chapter 4, Troubleshooting and Maintaining the CN4

4 Tap the Scan tab to view a list of available 802.11 networks. The list includes the signal strength, channel, and MAC address for each network.

•

Tap Scan to refresh the screen.

5 Tap the Supp tab to view radio supplicant information, including a list of supplicant events and authentication status.

•

To verify the settings for the currently active security profile, tap Configure Profile. The Profile Wizard for the active profile appears.

•

To try reconnecting to the network, tap Reconnect.

•

To delete the events in the list, tap Clear Events.

CN4 Mobile Computer User’s Manual

95

Page 108

Chapter 4, Troubleshooting and Maintaining the CN4

6 Tap the Ping tab to run a ping test to the host.

To run a ping test: a In the Host field, enter the IP address of the host. b From the Repetitions list, choose the number of times the CN4 will ping the host. c

Tap Ping. The graph shows the amount of time it takes for the host to return the ping. Tap List to see this information in a list format.

7 Tap the RSSI tab to view the received signal strength of the host signal.

The information box includes the current signal strength, host SSID name, MAC address, data rate, and transmit power. 96

CN4 Mobile Computer User’s Manual

Page 109

Chapter 4, Troubleshooting and Maintaining the CN4

•

Tap Mark to place an arrow marker above the graph.

8 Tap the Conf tab to set up a log file that lists RSSI history.

This screen includes the 802.11 radio driver version and available radio modes. To create a log file: a Check the Log to File check box. b (Optional) Change the sample period and number of samples displayed. c

Tap Log File. The Save As screen appears.

d (Optional) Change the name of the saved log file, the folder to which the file will be saved, the content type (log or text), and the location. e Tap Save.

Resetting the CN4 You rarely need to reset the computer. If the computer does not resume after pressing the Power button, or if the computer or an application locks up, you may need to reset the CN4. The CN4 uses the configuration currently saved in flash memory during the boot process. There are three ways to reset the CN4: •

Warm booting the CN4

•

Cold booting the CN4

CN4 Mobile Computer User’s Manual

97

Page 110

Chapter 4, Troubleshooting and Maintaining the CN4

•

Clean booting the CN4

Warm Booting the CN4 You may need to perform a warm boot to correct conditions where an application stops responding to the system. To warm boot the computer •

Press and hold the Power button for 10 seconds. Or,

•

Right-click on the CN4 via the SmartSystems console and select Intermec Power Tools > Warm Boot Device.

The computer systematically shuts down, restarts, and goes through the initialization process.

Cold Booting the CN4 In some cases where the computer completely stops responding, you may need to perform a cold boot. Because cold booting may result in data loss, use this method only if all other recovery methods have failed. Note: Cold booting the CN4 does not guarantee that cached disk data will be saved, so transactional data may be lost during the reset. All other data, such as CN4 configuration and network settings, is preserved. To cold boot your CN4 1 Press the Power button to suspend the CN4. 2 Remove the battery pack from the CN4. 3 Use the stylus to press the Reset button on the back of the CN4.

98

CN4 Mobile Computer User’s Manual

Page 111

Chapter 4, Troubleshooting and Maintaining the CN4

Reset button

Locating the Reset Button on the CN4

Clean Booting the CN4 A clean boot erases the memory in the mobile computer, including all applications and data files found in the ObjectStore, and loads only the default files and programs required by the CN4 operating system. During a clean boot, the CN4 first looks for the SSPB files on an installed miniSD card. If no card is found, the CN4 loads the SSPB files in the Flash File Store. Files found on a miniSD card during a clean boot are copied into the Flash File Store and overwrite the existing SSPB files. If the CN4 seems to be locked up, try warm booting and then cold booting the computer. If neither method works, use a clean boot to get the CN4 up and running for further troubleshooting. The clean boot process is as follows: • initial boot > SSPB installation > reboot > DCE installation > SRs copied to CabFiles folder > _sstransferagent.xml run > reboot > CabFiles folder contents run > reboot, if required.

To clean boot the computer 1 Press the Power button to suspend the CN4. 2 Remove the battery pack from the back of the CN4. 3 Use the stylus to press the Reset button on the back of the CN4.

CN4 Mobile Computer User’s Manual

99

Page 112

Chapter 4, Troubleshooting and Maintaining the CN4

4 Insert the battery pack into the CN4, and immediately press and hold the Power button and both buttons on the left side. 5 Continue to hold the Power button and both buttons on the left side until a Warning message appears on the display. 6 Release the Power button and both buttons on the left side, read the message, and press either button on the right side to continue. 7 Wait for the CN4 to load files from its ROM. Note: You can also clean boot the CN4 using the SmartSystems console. To clean boot the CN4 using the SmartSystems console, right-click the CN4 and select Intermec Power Tools > Clean Boot Device.

Cleaning the CN4 To keep the CN4 in good working order, you may need to clean the imager window, color camera window, and the touch screen. Clean the windows and the touch screen as often as needed for the environment in which you are using the CN4. To clean the CN4, use a solution of ammonia and water. There are no user-serviceable parts inside the CN4. Opening the CN4 will void the warranty and may cause damage to the internal components. To clean the imager window, camera window, and touch screen 1 Press the Power button to suspend the CN4. 2 Dip a clean cloth towel in the ammonia solution and wring out the excess. 3 Wipe off the imager window, camera lens, and flash area. Do not allow any abrasive material to touch these surfaces. 4 Wipe dry.