Page 91
Chapter 3, Developing and Installing Applications
Field Definitions for ImageCapture_Config.xml (continued) Field Name
Valid Values
Description allowChanges
True or false
Default is false. If set to true, user can change the directory where saved images are stored.
imageLocation
File path
Default is no value. If no value is provided, the application does not change the directory where saved images are stored (My Documents\ ImageCapture).
allowChanges
True or false
Default is false. When set to true, user can change the filename template setting.
fileName
String of up to 200 characters
Name to be used for saved image files. If the name is identical to a file already saved, Image Capture adds a numeric character to the end of the file name.
allowChanges
True or false
Default is false. When set to true, user can change the file format type.
fileFormat
BMP, JPEG
Default is no value. If no value is provided, Image Capture does not change the file format setting. If no format is selected, the file is saved as a .bmp.
allowChanges
True or false
Default is false. When set to true, user can change the compression quality setting.
compressionQuality
0% to 100$
Default is no value. If no value is provided, the application does not change the compression quality setting. The higher the value, the better the quality, and the larger the file size will be. If fileFormat is set to BMP, this setting is not used.
Image Location
File Name
Output Compression
Compression Quality
CN4 Mobile Computer User’s Manual
79
Page 92
Chapter 3, Developing and Installing Applications
Image Capture XML Example This XML demonstrates how to use the fields as defined in the previous section. <?xml version="1.0" encoding="utf-8" ?> <ImageCapture xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xsd="http://www.w3.org/2001/XMLSchema"> <Settings allowChanges ="true" allowGallery="true"> <Conditioning allowChanges="true"> <edgeEnhancement allowChanges="true">None</edgeEnhancement> <lightingCorrection allowChanges="true">Enabled</lightingCorrection> <noiseReduction allowChanges="true">0</noiseReduction> <imageRotation allowChanges="true">90</imageRotation> <subsampling allowChanges="true">None</subsampling> </Conditioning> <Storage allowChanges="true"> <imageLocation allowChanges="false">\My Documents\ImageCapture </imageLocation> <fileName allowChanges="false"> Image_$(num)</fileName> </Storage> </Settings> </ImageCapture>
Freeing Up Virtual Memory for Applications You can use the InstallSelect application to free up virtual memory and create more space to load and run custom applications. Note: InstallSelect is designed for use only by administrators, developers, integrators, or Intermec service representatives. When you free up virtual memory, you reduce the amount of virtual memory used by portions of the SmartSystems Platform Bundle (SSPB) by removing value-added software features. Be sure to close all other applications and back up any related files before you use InstallSelect. For more information on SSPB, see “Upgrading the System Software” on page 82. Removing software features may result in loss of computer functionality or the ability to manage device settings. Contact your Intermec service representative for information about each software feature before making changes. 80
CN4 Mobile Computer User’s Manual
Page 93
Chapter 3, Developing and Installing Applications
To free up virtual memory 1 Go to Start > Programs > File Explorer. 2 Browse to the Windows folder and scroll down to find InstallSelect. 3 Tap InstallSelect. A Caution message appears, reminding you that removing files may reduce functionality. 4 Tap OK to clear the message. The InstallSelect screen appears.
5 Clear the check box for each component you do not want installed after a clean boot. For a description of each component, see the next table. 6 Tap Apply to start the clean boot. A confirming message appears. 7 Tap Yes to continue. The CN4 performs a clean boot. Only the components you selected are installed. InstallSelect Software Components Component Name
Description
Avalanche Enabler
Enables the client to the Wavelink Device Management solution.
Data Collection & Intermec Settings
Enables data collection components, including the scanner and decode engines, and Intermec Settings. Also includes on-unit SDK libraries.
Funk Wireless Security
Intermec security supplicant that provides a wireless security solution with several features that are not supported by Microsoft.
CN4 Mobile Computer User’s Manual
81
Page 94
Chapter 3, Developing and Installing Applications
InstallSelect Software Components (continued) Component Name
Description
Printer Support
Provides Intermec printer driver support.
Intermec DHCP Client
Provides the Intermec DHCP client application.
Printer_Configlet
Intermec Settings configuration support for Bluetooth printers.
Bluetooth
Intermec Bluetooth integration support.
IDLRuntime
Runtime files supporting the Data Collection and Device Resource Kits.
Document Imaging
Enhanced Mobile Document Imaging components. Supported by CN4s with the EA21 area imager.
Image Capture
Image Capture application and components. Supported by CN4s with the EA21 area imager.
Power Profiler
Power Profiler applet.
GPS Applet iGPS Settings applet.
Additional Files
Microsoft C Runtime Library
Depending on the options installed in your CN4, you may see other components available from the InstallSelect application.
Upgrading the System Software When you upgrade your computer, you are updating the operating system (OS) and the SmartSystems Platform Bundle (SSPB) files. You can choose to upgrade only the operating system. If you upgrade only the operating system, you will need to reinstall the SSPB files. SSPB files are stored in the Flash File Store and deliver Intermec value-add (IVA) functionality such as data collection, configuration, Intermec Bluetooth integration, the Intermec wireless security suite, and the SmartSystems Reference Client. As new features are added to these components, you can update your SSPB files without updating the operating system. If you have any SRs (service releases) that you want to install, you can copy them to this directory: • 82
\Flash File Store\SSPB\SRS CN4 Mobile Computer User’s Manual
Page 95
Chapter 3, Developing and Installing Applications
There are two ways to upgrade your computer: •
You can upgrade your computer using the SmartSystems console. For help, see “Upgrading the CN4 Using SmartSystems Foundation” on page 84.
•
You can upgrade your computer using a storage card. For help, see “Upgrading the CN4 Using a miniSD Card” on page 85.
Locating Upgrade Files Before you can upgrade, you need to download the latest upgrade files from the Intermec website to your desktop PC. To download the upgrade files 1 Open a web browser and go to www.intermec.com. 2 Choose Support > Downloads and choose these items: a In the Product Category list, choose Computers. b In the Product Family list, choose Handheld Computers. c
In the Product list, choose CN4 Mobile Computer.
3 Click Submit. A list of downloadable software appears. 4 Look for the appropriate upgrade files in the OS/Firmware/ Drivers list, and click a filename to download it. If you are managing the CN4 with SmartSystems Foundation, Intermec Update alerts you when new upgrades or software are available. You can have the upgrades and software installed to the console for immediate use. For information, see “Managing the CN4 With SmartSystems Foundation” on page 44.
CN4 Mobile Computer User’s Manual
83
Page 96
Chapter 3, Developing and Installing Applications
Upgrading the CN4 Using SmartSystems Foundation You can use the SmartSystems Foundation console to upgrade the operating system on your CN4. For information on using SmartSystems Foundation, see “Managing the CN4 With SmartSystems Foundation” on page 44. To upgrade the CN4 using SmartSystems Foundation 1 On your desktop PC, open the SmartSystems console. 2 Make sure the SmartSystems console and the CN4 are on the same subnet. 3 Make sure the CN4 is either in a communications dock or charging dock, or the device power management is disabled. 4 Download the device upgrade file to your PC as described in the previous section, “Locating Upgrade Files.” 5 Double-click the .exe file on your PC. An InstallShield application starts and walks you through the process of extracting the upgrade files to the default location. Note: Do not change the default location where InstallShield extract the files. The SmartSystems console requires the files to be in this location. 6 From the SmartSystems console, locate the device upgrade to install. 7 Drag the file to each CN4 you want to upgrade or to a group of CN4s in a folder. The SmartSystems console installs the upgrade on your computers. After the download is complete, your CN4 replaces the operating system and automatically performs a cold boot. Note: The SmartSystems console displays a red stop sign symbol, indicating that the CN4 is offline, until the CN4 reboots and reconnects to the system.
84
CN4 Mobile Computer User’s Manual
Page 97
Chapter 3, Developing and Installing Applications
Upgrading the CN4 Using a miniSD Card To use a miniSD card to upgrade the computer, you need an SD card reader and a miniSD adapter card formatted as FAT16. To upgrade the operating system using a miniSD card 1 Copy all required OS upgrade files to the miniSD card. 2 Insert the miniSD card into the CN4. For help, see “Installing a miniSD or SIM Card” on page 37. 3 Place the CN4 in a dock connected to external power and use a stylus to press the Reset button located in the battery cavity on the back of the CN4. For help, see “Cold Booting the CN4” on page 98. 4 Remove the miniSD card when the Installation Complete menu appears. 5 Remove the CN4 from the dock and replace the battery. To upgrade the SSPB using a miniSD card 1 Copy all required SSPB upgrade files to the miniSD card. 2 Insert the miniSD card into the CN4. 3 Clean boot the CN4. For help, see “Clean Booting the CN4” on page 99. When the clean boot is complete, the CN4 warm boots to reset the configuration. 4 (Optional) Remove the miniSD card or delete the files on the miniSD card. During the clean boot, the files were copied from the miniSD card to the Flash File Store. 5 Set the network communication parameters to reestablish communications with the other devices in the wireless network.
CN4 Mobile Computer User’s Manual
85
Page 98
Chapter 3, Developing and Installing Applications
86
CN4 Mobile Computer User’s Manual