Page 73

4

Troubleshooting and Maintaining the CN2G

Use this chapter to solve problems you may encounter while using the CN2G. You will also find information on booting the computer and routine maintenance. If you have any problems using the CN2G, look in this chapter to find a possible solution. This chapter consists of the following sections: • Problems While Operating the CN2G • Problems While Configuring Security • Problems With Wireless Connectivity • Problems While Scanning Bar Codes • Booting the CN2G • Cleaning the Scanner Window and CN2G Screen

CN2G Handheld Computer User’s Manual

63

Page 74

Chapter 4, Troubleshooting and Maintaining the CN2G

Problems and Solutions If you send the CN2G in for service, it is your responsibility to save the computer data and configuration. Intermec is responsible only for ensuring that the keypad and other hardware features match the original configuration when repairing or replacing your computer.

Problems While Operating the CN2G Problem

Solution

You press the Power key to turn on the CN2G and nothing happens.

Make sure you have a charged battery installed correctly. For help, see “Installing and Charging the Battery” on page 4. The battery may be discharged. Replace the battery with a spare charged battery, or charge the battery and try again.

You press the Power key to turn off the CN2G and nothing happens.

If the CN2G is processing data, it may not turn off when you press the Power key. Wait until the CN2G finishes processing. If the CN2G appears to be locked up, warm boot the CN2G. For help, see “Warm Booting the CN2G” on page 70. If the CN2G does not respond to a warm boot, see “Cold Booting the CN2G” on page 71.

The CN2G screen is not responding to the stylus.

Try these possible solutions in order: • Recalibrate the screen. For help, see “Calibrating the

Screen” on page 12. • Press and hold the Power key for approximately 2 seconds, and then release it to turn off the CN2G. Press the Power key again to turn on the CN2G. You place the CN2G in the communications dock, and the Battery light turns on and is orange.

64

• The temperature may not be within the charging range. Make sure that the temperature is from 0°C to 45°C (32°F to 113°F). • The battery may be damaged. Replace the battery.

CN2G Handheld Computer User’s Manual

Page 75

Chapter 4, Troubleshooting and Maintaining the CN2G

Problems While Operating the CN2G (continued) Problem

Solution

The CN2G appears to be locked up and you cannot enter data.

Try these possible solutions in order: • Wait at least 10 seconds and try again. If the CN2G is still connecting to the Intermec Application Server or the host, it ignores any input from the keypad or scanner. • Press and hold the Power key for approximately 2 seconds, and then release it to turn off the CN2G. Press the Power key again to turn on the CN2G. • Perform a warm boot on the CN2G. For help, see

“Warm Booting the CN2G” on page 70. • Perform a cold boot on the CN2G. For help, see

“Cold Booting the CN2G” on page 71. • Try reloading the firmware. For help, see “Upgrading

Your CN2G” on page 57. • If the CN2G will not boot or reset, contact your local

Intermec service representative for help.

Problems While Configuring Security Problem

Solution

The CN2G indicates that it is authenticated, but it does not communicate with the host.

Make sure that the CN2G IP address, host IP address, subnet mask, and default router are properly configured for your network.

The CN2G does not appear to be authenticating and a network connection icon does not appear on the status bar. To see a list of network connections icons, see “Understanding the Screen Icons” on page 12.

The CN2G may not be communicating with your access point. Make sure the network name on the CN2G is the same as the network name (SSID) of the access point that you are trying to communicate with. The default network name is “INTERMEC.”

CN2G Handheld Computer User’s Manual

The 802.1x security network may not be active. Make sure that the server software is properly loaded and configured on the server PC. For help, see the documentation that shipped with your server software.

65

Page 76

Chapter 4, Troubleshooting and Maintaining the CN2G

Problems While Configuring Security (continued) Problem

Solution

A network connection icon appears in the status bar, but it disappears.

The CN2G may not be communicating with the access point that you want it to communicate with. Make sure that the network name on the CN2G is the same as the network name of the access point that you are trying to communicate with. The default network name is “INTERMEC.” The access point that you are trying to communicate with may not be communicating with the server. Make sure your access point is turned on, properly configured, and has 802.1x security enabled.

You receive a message saying, “The server certificate has expired or your system date is incorrect” after you cold boot the CN2G.

The date and time on the CN2G are not saved through a cold boot. You need to re-enter the date and time and then save your changes.

The CN2G indicates that it is not authenticated.

Make sure that: • The User Name and Password parameters on your

CN2G match the user name and password on your authentication server. You may need to re-enter the password on both your CN2G and the authentication server. • On your authentication server, the user and group are allowed and the group policy is allowed to log in to the server. For help, see the documentation that shipped with your authentication server software. • The IP address and secret key for your access point must match the IP address and secret key on your authentication server. You may need to re-enter the IP address and secret key on both your access point and authentication server. • The authentication server software is running on the server PC. You are setting up multiple access points in a network, with different SSIDs, and the connection fails.

66

The CN2G does not save WEP key values when you change the SSID. Re-enter the WEP key value after you change the SSID and save your changes. You should now be able to connect to the different access points. CN2G Handheld Computer User’s Manual

Page 77

Chapter 4, Troubleshooting and Maintaining the CN2G

Problems With Wireless Connectivity Problem

Solution

When you turn on the CN2G after it was suspended for a while (10-15 minutes or longer), it can no longer send or receive messages over the network.

The CN2G may not be recognizing the network card. Turn off the CN2G, and then turn it on again.

The network connection icon is in the status bar, but the host computer is not receiving any data from the CN2G.

In a UDP Plus network, there may be a problem with the connection between the Intermec Application Server and the host computer. Check with your network administrator or see the user’s manual for the Intermec Application Server.

The host may have deactivated or lost your current terminal emulation session. In a TCP/IP direct connect network, you need to turn off the “Keep Alive” message (if possible) from the host so that the TCP session is maintained while a CN2G is suspended.

In a TCP/IP network, there may be a problem with the connection between the access point and the host computer. Check with your network administrator or use your access point user’s manual. The no network connection icon ( ) appears on the status bar. The CN2G is not communicating with the access point.

The CN2G is not connected to the access point. Make sure the access point is turned on and operating. You may also be using the CN2G out of range of an access point. Try moving closer to an access point to re-establish communications. Make sure the CN2G is configured correctly for your network. The radio parameters on the CN2G must match the values set for all access points the CN2G may communicate with. For help, see “Configuring 802.11b Radio Communications” on page 27. If you have an 802.11b radio, the radio initialization process may have failed. Try resetting the CN2G. See “Booting the CN2G” on page 70. If you have tried these possible solutions and the no network connection icon still appears, you may have a defective radio card. For help, contact your local Intermec service representative.

CN2G Handheld Computer User’s Manual

67

Page 78

Chapter 4, Troubleshooting and Maintaining the CN2G

Problems With Wireless Connectivity (continued) Problem

Solution

The CN2G is connected to the Intermec Application Server or host computer and you move to a new site to collect data. The network connection icon was visible but now the no network connection icon ( ) is visible.

You may have gone out of range of an access point. Try moving closer to an access point or to a different location to re-establish communications. Once you are in range again, the network connection icon appears again. Any data you collected while out of range is transmitted over the network.

Problems While Scanning Bar Codes Problem

Solution

You cannot see a red beam of light from the scanner when you press the Scan button or one of the Side Scan buttons and aim the scanner at a bar code label.

There are three possible problems: • You may be too far away from the bar code label.

Try moving closer to the bar code label and scan it again. • You may be scanning the bar code label “straight on.” Change the scanning angle and try again. • The PSM files may not be correctly installed. For help, see “Upgrading the Persistent Storage Manager Files” on page 60. You can test the effective range of the scanner. Move within 61 cm (2 ft) of a wall and test the scanner. You need to be within the scanning range to scan bar code labels. For help scanning bar codes, see “Scanning Bar Codes” on page 14. When you release the Scan button or Side Scan button, the Good Read light does not turn off.

68

The Good Read light will remain on if you configure the CN2G to use continuous/edge triggering. If you configure the CN2G for level triggering and the Good Read light remains on, there may be a problem. Press the Scan button or one of the Side Scan buttons again without scanning a bar code label. If the light is still on, contact your local Intermec service representative.

CN2G Handheld Computer User’s Manual

Page 79

Chapter 4, Troubleshooting and Maintaining the CN2G

Problems While Scanning Bar Codes (continued) Problem

Solution

The scanner will not read the bar code label.

Make sure you aim the scanner beam so it crosses the entire bar code label in one pass. The angle you are scanning the bar code label may not be working well, or you may be scanning the label “straight on.” Try scanning the bar code label again, but vary the scanning angle. The bar code label print quality may be poor or unreadable. To check the quality of the bar code label, try scanning a bar code label that you know will scan. Compare the two bar code labels to see if the bar code quality is too low. You may need to replace the label that you cannot scan. Make sure the bar code symbology you are scanning is enabled. Use Intermec Settings to check the symbologies. If your bar code symbology is disabled, enable it and then try scanning the bar code label again. Make sure that the application you are running on the computer is expecting input from a bar code. You may need to use the input panel to enter this information instead of scanning it.

The scanner does not read the bar code labels quickly, or the scanning beam seems to be faint or obscured.

The scanner window may be dirty. Clean the window with a solution of ammonia and water. Wipe dry. Do not allow abrasive material to touch the window.

You scan a valid bar code label to enter data for your application. The data decoded by the CN2G does not match the data encoded in the bar code label.

The computer may have decoded the bar code label in a symbology other than the label’s actual symbology. Try scanning the bar code label again. Make sure you scan the entire label.

CN2G Handheld Computer User’s Manual

To operate the computer quickly and efficiently, you should only enable the bar code symbologies that you are going to scan.

69

Page 80

Chapter 4, Troubleshooting and Maintaining the CN2G

Booting the CN2G You seldom need to warm or cold boot the CN2G. The CN2G uses the configuration currently saved in flash memory during the boot process. You need to boot the CN2G when an application is locked up and will not respond, when you upgrade the firmware, or when you reflash the computer. The next instructions explain how you warm and cold boot the CN2G.

Warm Booting the CN2G If your charged CN2G does not resume after pressing the Power key, or if the computer or an application is locked up, you may need to warm boot it. To warm boot the CN2G using the Warm Boot button • Using the end of the stylus, press the Warm Boot button inside of the stylus holder.

Wa Boo but

After approximately 10 seconds, the screen flickers. The Refreshing the File System dialog box appears, and the CN2G warm boots.

70

CN2G Handheld Computer User’s Manual

Page 81

Chapter 4, Troubleshooting and Maintaining the CN2G

To warm boot the CN2G using the Power key 1 Press and hold the Power key for approximately 10 seconds until the screen flickers. Note: After about 8 seconds, the CN2G desktop appears briefly. Keep holding the Power key for another 2 seconds until the screen flickers. 2 Release the Power key. The Refreshing the File System dialog box appears, and the CN2G warm boots.

Cold Booting the CN2G If the CN2G or application is locked up and does not respond to a warm boot, follow this procedure to perform a cold boot. When you perform a cold boot, all data in your RAM storage is deleted. To cold boot the CN2G 1 Open the battery door and remove the battery. 2 Using the end of the stylus, press the Reset button on the inside of the battery compartment.

Reset button

Do not use force or a sharp object when pressing the Reset button. You may damage the Reset button. 3 Install the battery and battery door. After approximately 4 seconds, the CN2G starts the power on sequence. CN2G Handheld Computer User’s Manual

71

Page 82

Chapter 4, Troubleshooting and Maintaining the CN2G

Note: Date and time settings are not saved through a cold boot. You will need to reset the time and date.

Cleaning the Scanner Window and CN2G Screen To keep the computer in good working order, you may need to clean the scanner window. Clean the scanner window as often as needed for the environment in which you are using the computer. To clean the CN2G, use a solution of ammonia and water. There are no user-serviceable parts inside the CN2G. Opening the unit will void the warranty and may cause damage to the internal components. To clean the scanner window 1 Press and hold the Power key for approximately 2 seconds, and then release it to turn off the CN2G. 2 Dip a clean towel or rag in the ammonia solution and wring out the excess. Wipe off the scanner window and screen. Do not allow any abrasive material to touch these surfaces. 3 Wipe dry.

72

CN2G Handheld Computer User’s Manual