Page 56

Chapter 2, Configuring the CK30

Configuring the CK30 Through the Network You can change the configuration parameters of the CK30 by sending commands through a host PC or through the network. If you are using a network, you can configure one or more CK30s at a time. If a CK30 has already been configured for your wireless network, you can remotely configure the CK30 by sending a command from an application on the host PC. You cannot set all parameters through the network. You can only set those commands that have a syntax in the Intermec Computer Command Reference Manual. Note: You can continue running an application on the CK30 while configuring it from the host.

Configuring the CK30 in a UDP Plus Network You can use the host computer to configure a CK30 in your wireless network. To send and receive configuration data or files, you need to write a host application that can communicate with the Intermec Application Server. For help, see the appropriate Intermec Application Server user’s manual. You use the Terminal Message Format (TMF) protocol to send and receive transactions between the host application and the CK30. To set up the Intermec Application Server • Configure a peer-to-peer destination name for the host application. Create a transaction ID, $NGCFGRSP, that will be routed to this destination name. The Intermec Application Server uses the transaction ID to route responses from the CK30 back to the host application. $NGCFGRSP is a special transaction ID that the server uses to forward configuration response data from a CK30. All configuration responses are routed with the $NGCFGRSP transaction ID. The Intermec Application Server cannot keep track of multiple applications sending reader or configuration commands. If you have two host applications sending reader or configuration commands, they must both be configured to receive the $NGCFGRSP transactions, and therefore both will receive all responses from all CK30s. 42

CK30 Handheld Computer User’s Manual

Page 57

Chapter 2, Configuring the CK30

To set up the host computer • Verify that the host computer can communicate with the Intermec Application Server. To set up the application • Prepare and write a host application that can communicate with the Intermec Application Server and send transactions to and receive transactions from the CK30 in this format: transaction header

TMF field commands where: transaction header is a 96-byte field containing the message number, date and time, source application ID, destinations application ID, transaction ID, and other information. You must set the system message (SYS$MSG) flag to E in the transaction header. For help, see the Intermec Application Server user’s manual.

TMF field is a 2-byte field containing one of these values:

commands

CG

Configuration Get request sent from the host application.

Cg

Configuration Get response sent from the CK30 to the host.

CS

Configuration Set request sent from the host application.

Cs

Configuration Set response sent from the CK30 to the host.

are the reader and configuration commands that you want to set on the CK30 or the current value you want to retrieve from the CK30. To save configuration changes in flash memory, send the reader command .+1 as the last command. For a list of all supported commands, see the Intermec Computer Command Reference Manual.

CK30 Handheld Computer User’s Manual

43

Page 58

Chapter 2, Configuring the CK30

To see an example of the host application transaction, see the example on page 45.

Configuring the CK30 in a TCP/IP Direct Connect Network You can use the host computer to configure a wireless CK30 in your TCP/IP network. To send and receive configuration data, you need to write a host application that can communicate with the CK30 directly through an access point or through the Ethernet network. Use the Terminal Message Format (TMF) protocol to send and receive transactions between the host application and the CK30. To set up the host computer • Verify that you can communicate with the CK30. To set up the application • Prepare and write a host application that can communicate with the CK30. Send message transactions to and receive transactions from the CK30 on the network port using this format: TMF field commands where: TMF field is a 2-byte field containing one of these values: CG Configuration Get request sent from the host application. Cg

Configuration Get response sent from the CK30 to the host.

CS Configuration Set request sent from the host application. Cs commands

44

Configuration Set response sent from the CK30 to the host.

are the reader and configuration commands that you want to set on the CK30 or the current value you want to retrieve from the CK30. To save configuration changes in flash memory, send the reader command .+1 as the last command. CK30 Handheld Computer User’s Manual

Page 59

Chapter 2, Configuring the CK30

For a list of all commands, see the Intermec Computer Command Reference Manual.

Example In the host application, you want to get the current values of two configuration commands from the CK30. Send this transaction from the host application: CG$+NABV

Note: The transaction header is not shown in this example. You do not need a transaction header for a host application in a TCP/IP network, but you do for a UDP Plus network. where: CG is a TMF Configuration Get request.

$+ is the Change Configuration reader command.

BV is the Beeper Volume configuration command.

The CK30 returns this transaction to the host application. Cg$+BV4 where: Cg is a TMF Configuration Get response.

$+ is the Change Configuration reader command.

BV4 means the Beep Volume configuration command is currently set to a value of 4, which is a very high beeper volume.

Synchronizing the CK30 System Time With a Time Server It is important that the time on all of your CK30s be synchronized with a network time server to ensure real-time communications and updates. Network time servers acquire Coordinated Universal Time (UTC) from an outside source such as the U.S. Naval Observatory (USNO). The CK30 uses Simple Network Time Protocol (SNTP) to synchronize with a network time server.

CK30 Handheld Computer User’s Manual

45

Page 60

Chapter 2, Configuring the CK30

The default reference time server is the USNO (tock.usno.navy.mil). To synchronize the time on your CK30 with this time server, you must have a valid connection to the Internet. You can also synchronize the CK30 system time with a corporate network server within your firewall that is SNTP capable. To use an internal corporate network server, you need to set the domain name in the registry.

Configuring the CK30 for Your Network The CK30 is a versatile handheld computer that you can easily add to your wired or wireless data collection network. You can connect your CK30 to your network using: • Serial communications • 802.11b/g radio communications • Ethernet communications • Bluetooth™ radio communications

Configuring Serial Communications The CK30 has a serial port to transfer data to and receive data from another device via RS-232 communications. You can also insert the CK30 into a communications dock to transmit data to and receive data from a host computer or PC using RS-232 communications. The serial cable and the communications dock are sold separately. For more information on accessories and how to order them, see page 150.

46

CK30 Handheld Computer User’s Manual

Page 61

Chapter 2, Configuring the CK30 Host

Ethernet

Serial cable

PC

CK30

CK30 in a Serial Network

To use serial communications with your CK30 1 Turn off the CK30. 2 Connect the CK30 to the serial port of another device. You can do this in one of the following ways: • Connect the CK30 serial port to the serial port of the other device using the AA1 (26-pin to DB9-pin) serial cable adapter and a female-to-female null modem RS-232 cable. • Connect the AD1 or AD2 communications dock to the serial port of the other device using a DB9-pin to DB9-pin serial adapter cable. Insert the CK30 into the dock. 3 Turn on the CK30.

CK30 Handheld Computer User’s Manual

47

Page 62

Chapter 2, Configuring the CK30

Configuring 802.11b/g Radio Communications Make sure all components with antennas are at least 30 cm (1 ft) apart when power is applied. Failure to comply could result in equipment damage. The wireless CK30 has an internal 802.11b/g radio to transfer data using wireless communications. This section of the manual assumes that you have already set up your wireless communications network including your access points. If you are using a UDP Plus network, you also need to have your Intermec Application Server communicating with a host computer. Your CK30 supports these network protocols: • TCP/IP • UDP Plus The next sections explain the parameters you need to configure for the CK30 to work in your wireless network.

Configuring the Network Parameters for a TCP/IP Network In a TCP/IP network, the CK30 communicates with a host computer directly using TCP/IP. The access point acts as a bridge to allow communications between the wired network and the wireless network.

48

CK30 Handheld Computer User’s Manual

Page 63

Chapter 2, Configuring the CK30 Host

TCP/IP Direct Connect

Ethernet

Access point

CK30s

CK30s in a TCP/IP Direct Connect Network

To use wireless communications in a TCP/IP network 1 Configure these network parameters on each CK30 in the network: • Network Name (SSID) • IP Settings (if not using DHCP) 2 Make sure that your CK30 is talking to the network and that the network can see your CK30. 3 Configure security. For help, see “Configuring Security” on page 55. CK30 Handheld Computer User’s Manual

49

Page 64

Chapter 2, Configuring the CK30

The easiest way to configure the network parameters on the CK30 is to use the Configuration Utility. For help, see “Configuring the CK30 With the Configuration Utility” on page 36.

Configuring the Network Parameters for a UDP Plus Network In a UDP Plus network, the CK30 communicates with a host computer through the Intermec Application Server. Host

UDP Plus

Ethernet

Intermec Application Server Access point

CK30s

CK30s in a UDP Plus Network

50

CK30 Handheld Computer User’s Manual