Page 47

2

Configuring the CK30

Use this chapter to understand how to configure the CK30 to communicate in your network. In this chapter, you will find these sections: • How to Configure the CK30 Parameters • Configuring the CK30 for Your Network • Configuring Security • Saving Your Configuration Changes to Flash Memory

CK30 Handheld Computer User’s Manual

33

Page 48

Chapter 2, Configuring the CK30

How to Configure the CK30 Parameters You can configure many parameters on the CK30, such as the bar code symbologies it decodes or the network settings. These characteristics are controlled by configuration parameters. The values you set for these configuration parameters determine how the computer operates. There are several ways to configure the CK30: Use Setup Assistant on the CK30

Use Configuration Utility on the CK30

Use Setup Assistant to quickly enter network parameters.

Use the Configuration Utility to set all parameters.

Use the SmartSystems Console

Use Configuration Commands Send commands through the network to your CK30s. Ethernet or Wireless Network

Use Intermec Settings from within the SmartSystems Console to remotely configure network parameters.

Scan Bar Codes

Scan bar codes to configure basic CK30 and data collection parameters.

34

CK30 Handheld Computer User’s Manual

Page 49

Chapter 2, Configuring the CK30

Configuring the CK30 With the Setup Assistant When first setting up the CK30, use the Setup Assistant to set or enable basic network parameters and connect your CK30 to the network. The Setup Assistant guides you through setting the following basic network parameters: • Date and time • 802.11 radio • WEP security • DHCP server or IP address, subnet mask, and default router • Device name Note: If you are using the CK30 in an EasyADC system, enable the ION client. Your CK30 configures the security parameters, reboots, and launches the TE 2000 application. When the CK30 connects to its host, the Intermec Ready-to-Work Indicator turns on solid blue. To set other parameters, use the Configuration Utility or another configuration method. The Setup Assistant runs on the CK30 the first time you turn on the computer.

The Setup Assistant Start Screen

After you complete the Setup Assistant, the CK30 should be communicating with your network.

CK30 Handheld Computer User’s Manual

35

Page 50

Chapter 2, Configuring the CK30

Configuring the CK30 With the Configuration Utility Use the menu-driven Configuration Utility to configure the CK30 and view system information. You can access the Configuration Utility while running any application. Tip: To easily navigate through the CK30 menus, press the numbers to the left of the option you want to select. To open the Configuration Utility 1 Press C and then B to open the System Main Menu.

2 Select the Configuration Utility. The Configuration Utility main menu appears.

Refer to the next sections to understand your menu options, learn how to navigate and enter information, and learn how the menus are organized in the Configuration Utility. For help understanding the commands and parameters, see the Intermec Computer Command Reference Manual (P/N 073529).

36

CK30 Handheld Computer User’s Manual

Page 51

Chapter 2, Configuring the CK30

When using the Configuration Utility, you may not see a parameter until you enable or disable a value for another key field. For example, you will not see IP Settings unless you disable DHCP. You may also not see a parameter if your computer does not support a particular feature. Use the following diagram to find the commands you need to use to configure your CK30s. These screens do not represent the exact information you will see on your CK30. They have been modified to show you how the information is structured.

Configuration Utility Menus at a Glance

CK30 Handheld Computer User’s Manual

37

Page 52

Chapter 2, Configuring the CK30

Configuration Utility Menu Options Menu Option Data Collection

Description Configure scanner settings and bar code symbologies.

Communications

Set up network settings including the 802.11b/g radio and the Bluetooth radio.

Device Settings

Configure settings specific to the CK30 such as the date, time, beeper volume, and backlight timeout.

SmartSystems Information

Add information specific to the SmartSystems application such as identity, administrator, and location.

ION Configuration

Configure settings specific to the Instant On (ION) application.

Restore Defaults

Restore factory default settings on your CK30.

Save to Flash

Configure registry persistence so your settings are saved after a cold boot.

Printers

Configure settings for Bluetooth printers associated with the CK30.

Use this table to understand how to navigate and enter information in the Configuration Utility. Navigating in the Configuration Utility

38

To Do This: Select an option

Press: • The number associated with the option • a or b to select an option and then press Enter • Tab to select an option and then press Enter

Save a setting

F3 key

Exit or return to a previous screen

Esc until you exit the application or return to a previous screen

Delete a character

C key, Backspace key

Delete all characters in a highlighted field

Backspace key

CK30 Handheld Computer User’s Manual

Page 53

Chapter 2, Configuring the CK30

Navigating in the Configuration Utility (continued) To Do This: Return to the Configuration Utility main menu (Home)

Press: • On the 42-key and 52-key keypads, press C and then 8 • On the 50-key keypad , press C and then H

Restoring Default Settings You can restore the CK30 to factory default settings from the Configuration Utility. For a complete list of the default settings, see “Default Configuration Settings” on page 160. Note: Using the Restore Defaults option resets all network parameters. As a result, you may lose network communications. This option should only be used by network administrators or by Intermec support personnel. To restore factory default settings 1 From the Configuration Utility menu, select Restore Defaults. 2 Press Enter to select Restore Defaults. The following Restore Defaults dialog box appears.

3 Press Enter to restore factory defaults. Your CK30 performs a cold boot and returns all of your settings to the factory default settings. 4 If you have CAB files loaded on your CK30, you will see a Confirm File Replace dialog box. Select Yes to All and then press Enter. The CK30 installs your CAB files.

CK30 Handheld Computer User’s Manual

39

Page 54

Chapter 2, Configuring the CK30

When the CK30 is done booting, the Start Screen or the Setup Assistant appears depending on your settings. Note: You may need to reinstall some applications after restoring the default settings because any settings that were modified for your application will be reset.

Exiting the Configuration Utility You can exit the Configuration Utility at any time by pressing the Esc key. If you have made changes to your configuration, they will automatically be saved to flash if you save your changes. To exit the Configuration Utility 1 Press Esc until you return to the System Main Menu. If you have made any changes to your configuration, the Save Changes dialog box appears.

2 If you want to save your configuration, select Save changes. If you do not want to save your configuration changes, select Discard changes.

Configuring the CK30 With SmartSystems Console The SmartSystems™ Console lets you manage all your SmartSystems-enabled devices at the same time from a central host PC. The CK30 ships with a SmartSystems client, which means it is SmartSystems-enabled. The console displays all of the CK30s in your network. In the console, you can right-click a CK30 and a menu appears. To configure the CK30, choose Intermec Settings from the menu. The console is part of SmartSystems Foundation, which is available from the Intermec web site. Go to www.intermec.com/SmartSystems to download SmartSystems Foundation. For help using the console, see the online manual available from the Help menu in the console.

40

CK30 Handheld Computer User’s Manual

Page 55

Chapter 2, Configuring the CK30

Configuring the CK30 by Scanning Bar Codes You can change some of the configuration parameters of the CK30 by scanning Code 39 or Code 93 bar code labels containing configuration commands. This method is a fast and easy way to change just a few configuration parameters on a single CK30. You can only change some of the configuration parameters by scanning bar codes. To configure all of the configuration parameters, use the Configuration Utility or send commands through the network to your CK30. You can print and scan the bar code labels from the Intermec Computer Command Reference Manual or you can create your own bar code labels. For help, see the Intermec Computer Command Reference Manual. You can also use Intermec’s EasySet software to print configuration labels you can scan to change your configuration settings. For more information, see the EasySet online help. EasySet is available from the Intermec Data Capture web site. There are some limitations on using EasySet labels to change symbology configuration settings. Please use an alternate method of configuration for setting up symbologies. For example, you can use the Beeper Volume configuration command to adjust the beep volume of the CK30. Scan this bar code label to set the volume to the lowest (quietest) level: Beeper Volume Low

*$+BV1*

*$+BV1*

When you scan bar code configuration commands, the CK30 emits a series of beeps unless the volume is turned off. There are two beep sequences: • One high beep means you scanned a valid configuration command. • Three low beeps means you scanned an invalid configuration command.

CK30 Handheld Computer User’s Manual