The text of a manual · part 8 of 25
AI1620 SmartPass System Guide, pages 71 to 80
Pages 71 to 80 of 246
The original document is the PDF (4.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec AI1620 and Intermec SmartPass Reader AI1620
Page 71
Testing and Configuring SmartPass Before Installation
4
Note: An internal timer in SmartPass causes SmartPass to ignore a specific tag for 2 minutes after a good read unless a different tag is read in the meantime. 3.
When SmartPass reads the second tag successfully, SmartPass Host displays that tag’s information in the status window below the information for the first tag, as shown in Figure 4-8.
Figure 4-8 Second Successful Tag Read
If the read is unsuccessful, try the following actions:
•
Be sure the red/green pair are still twisted together as described in the section “Testing Using an Audible Circuit Tester” on page 44.
•
Ensure the tag you are using is compatible with the particular option of SmartPass you are working with. Some SmartPasses cannot read full-frame tags.
To determine if the SmartPass you are working with can read full-frame tags, refer to the section “General Configuration Settings” on page 4-12 for information on reading the configuration label. A SmartPass could have a label such as the following: AI1620 HI T 10 H where the HI indicates high RF power and the 10 indicates it can read only access control tags.
•
Using the audible circuit tester, verify that the reader is capable of reading the tag in the read zone. If it is, the problem is probably in the communications between SmartPass and the host.
4-19
Page 72
AI1620 SmartPass System Guide
Configuring SmartPass Parameters Follow the procedures in this section to configure SmartPass parameters using SmartPass Host v2.01. Procedures are listed in alphabetical order by parameter. The PC must be connected to and communicating with SmartPass, and SmartPass Host must be started, as described in the section “Verifying PC-to-SmartPass Communications” on page 4-15. Note: If you are using Wiegand mode, you must connect the PC or laptop to SmartPass using the RS-232 or RS-422 interface before attempting to send commands to the reader. You can leave the Wiegand interface connected during this procedure.
Appended Tag Data Use this procedure to set appended tag data parameters using SmartPass Host. See the section “30N Append Time and Date Selection” on page 7-10 and the section “31N Append Auxiliary Information Selection” on page 7-10 for more information. 1.
Select the Tag & RF drop-down menu and click on Appended Data. Figure 4-9 illustrates the options for appending information to tag data.
Figure 4-9 Select Appended Data Dialog Box
2.
Click the option you want to select; then click OK to make the change.
Check Tag SmartPass supports both host-invoked and periodic check tag operations. If a real tag is in the field when a check tag operation begins, the check tag operation will be aborted. The check tag operation involves use of internal check tag circuitry (internal check tag option). The circuit of an Amtech check tag is built into each reader to allow a host computer to remotely diagnose SmartPass. The host sends SmartPass command 8110 to activate the check tag. SmartPass transmits the RF signal, which is reflected back into the
4-20
Page 73
Testing and Configuring SmartPass Before Installation
4 receive circuits by the check tag, just as if a normal tag had been placed into the read zone. The check tag contains the data SYSTEM CHECK TAG that SmartPass will receive, decode, and send to the host system.
Use the following procedure to set check tag options using SmartPass Host. See the section “810 Disable Periodic Check Tag (Factory Default)” on page 7-41 for more information. 1.
Select the Tag & RF drop-down menu and click Checktag Options. Figure 4-10 illustrates the submenu for check tag operations.
Figure 4-10 Check Tag Options Submenu
Note: Only the internal check tag is available on the AI1620 SmartPass. Selecting the external check tag option will return an error message.
4-21
Page 74
AI1620 SmartPass System Guide
2.
To disable or enable periodic check tag, click Periodic Checktag option to display the Select Periodic Checktag Option dialog box, as shown in Figure 4-11.
Figure 4-11 Select Periodic Checktag Option Dialog Box
3.
Click the option you want to select; then click OK to make the change.
ID Separation The host can select a unique ID separation of one ID (command 4100) or two IDs (command 4101). The uniqueness timeout is fixed at 2 minutes. The reader default operation is for a unique ID separation of one ID and a uniqueness timeout of 2 minutes. The host computer can disable the uniqueness check using command 40 (transmit all IDs) or command 43 (buffer all IDs). In this case, every tag ID received will be transmitted without regard to uniqueness. The host can reinstate uniqueness checking with commands 4100 or 4101 (select ID separation). Use the following procedure to set ID separation using SmartPass Host. See the section “40 Transmit All ID Codes” on page 7-11 through the section “43 Buffer All ID Codes” on page 7-12.
4-22
Page 75
Testing and Configuring SmartPass Before Installation
1.
4
Select the Tag & RF drop-down menu and click on Tag Filter. Figure 4-12 illustrates the options for appending information to tag data.
Figure 4-12 Select Tag Filter Dialog Box
2.
Click the option you want to select; then click OK to make the change.
Sense Output Devices Both the RS–232 and RS–422 configurations used by SmartPass have two sense output circuits, sense output0 and sense output1. By default, SmartPass operates in predefined output mode where sense output0 and sense output1 are asserted every time a unique valid tag is read. Both sense output devices are asserted by issuing command 621 (select the predefined sense output mode). They are not asserted when tags are acquired in the transmit all or buffer all ID mode, or when SmartPass is operating in Wiegand mode. The sense output pulse duration is variable (command 67N). The host computer can disable the predefined sense output control by issuing command 6201 to turn sense output0 on or by issuing any of the following commands: 6200, 6201, 6202, or 6203. While under host control, the sense outputs are not automatically asserted when a valid tag is read. The host must issue command 621 to return to the predefined mode.
Reports SmartPass can be configured to transmit presence without tag reports and input status change reports. Both report messages are handled the same as incoming tag IDs and are buffered behind previously acquired tag IDs. A presence without tag report is transmitted in data mode only, and only if the system has a presence detector. This report is sent if a presence is detected without the detection of a valid tag ID.
4-23
Page 76
AI1620 SmartPass System Guide
If configured with command 82N Select Input Status Change Report Option to transmit input status change reports, the reader will transmit a message to the host any time the inputs change state. Input status change reports are transmitted in data mode only. Input status change reporting is disabled by default. Use the following procedure to set presence reporting using SmartPass Host. See the section “82N Select Input Status Change Report Option” on page 7-42. Also refer to Chapter 6 for information on message formats. 1.
Select the I/O drop-down menu and click the Presence Reports option. Figure 413 illustrates the options for disabling or enabling presence without tag reports.
Figure 4-13 Select Presence Report Option Dialog Box
2.
4-24
Click the option you want to select; then click OK to make the change.
Page 77
Testing and Configuring SmartPass Before Installation
3.
4
Select the I/O drop-down menu and click the Sensor Reports option. Figure 4-14 illustrates the options for sensor reports.
Figure 4-14 Select Sensor Report Option Dialog Box
4.
Click the option you want to select; then click OK to make the change.
Reset Reset reader (command 63) clears the tag and message buffer (not in ECP mode). In addition, it resets uniqueness, clears the power fail bit, and transmits the sign-on message. The reader returns to data mode following the completion of this command. Note: This command does not reset any of the configuration parameters. Use the following procedure to reset SmartPass using SmartPass Host. See the section “63 Reset Reader” on page 7-30.
4-25
Page 78
AI1620 SmartPass System Guide
1.
Select the Reader drop-down menu and click the Reset option, as shown in Figure 4-15.
Figure 4-15 Reader Reset option
SmartPass Host displays the sign-on message at the bottom of the screen, as shown in Figure 4-16.
Sign-on Message
Figure 4-16 Sign-On Message
4-26
Page 79
Testing and Configuring SmartPass Before Installation
4
Radio Frequency Caution The RF for each SmartPass at the site must be set according to the frequency specified in the FCC site license. You can do this using SmartPass Host or using a terminal emulation program and issuing the frequency command, as discussed in the section “642NN Select RF Operating Frequency” on page 7-31.
Caution Only trained, authorized installation and maintenance personnel are permitted by FCC to set the RF. SmartPass Host allows you to set the frequency range from 902 to 928 MHz in 0.5 MHz steps.
Caution The authorized frequency band in the U.S. is 902 to 904 MHz and 909.75 to 921.75 MHz. Contact Amtech if your application requires a frequency outside of this range. Use the following procedure to set the frequency range. 1.
To display the current RF setting, select the Tag & RF drop-down menu and click the RF Frequency option. The example in Figure 4-17 indicates a SmartPass frequency of 902.5 MHz.
Figure 4-17 Current RF Display Box
2.
To change the RF setting, select the Options drop-down menu and click on Send Command. This displays the Enter Command Code dialog box shown in Figure 4-18.
4-27
Page 80
AI1620 SmartPass System Guide
3.
Type in command 642NN, where NN is a hexadecimal value from 00 to 34, and press ENTER. See Table 7-1 on page 7-32 for a complete listing of the hexadecimal values and the corresponding frequencies. This sets the frequency from 902 to 928 MHz in 0.5 MHz steps. In the example shown in Figure 4-18, the command 64218 sets the frequency to 914 MHz.
Figure 4-18 Set RF option
The Select Transmission Option dialog box shown in Figure 4-19 will display.
Figure 4-19 Select Transmission Option Dialog Box
4.
4-28
Click the Single Transmission option; then click OK to send the command to SmartPass.