Page 61
Testing and Configuring SmartPass Before Installation
4
Connecting Colored Wire Pair Cable Table 4-3 shows the RS-232 colored wire assignments. Table 4-3 RS–232 Interface Signal Wiring for Colored Wire Pair Cable Colored Pair Wire Cable Signal from SmartPass
Connect Wire to Host DB9 Pin
Connect Wire to Host DB25 Pin
Black
Pin 2
Pin 3
Red
Pin 3
Pin 2
Yellow or black
Pin 5
Pin 7
Yellow
Pin 8
Pin 5
Red
Pin 7
Pin 4
Wire Pair from Color SmartPass
TxD, SmartPass output
Used
Red/Black RxD, SmartPass input Signal ground
Yellow/ Black
Optional for hardware handshaking RTS, SmartPass output Yellow/Red CTS, SmartPass input
To connect the interface, perform the following steps. 1.
Connect the black wire (transmit data) from the red and black SmartPass wire pair to pin 2 of the DB9 connector or pin 3 of the DB25 connector.
2.
Connect the red wire (receive data) from the red and black SmartPass wire pair to pin 3 of the DB9 connector or pin 2 of the DB25 connector.
3.
Connect either the yellow or black wire (logic ground) from the yellow and black SmartPass wire pair to pin 5 of the DB9 connector or pin 7 of the DB25 connector.
4.
Plug the DB9 connector or DB25 connector into the PC.
If the host is set up for hardware handshaking, use the following procedures. 5.
Connect the yellow wire (RTS) from the yellow and red SmartPass wire pair to pin 8 of the DB9 connector or pin 5 of the DB25 connector.
6.
Connect the red wire (CTS) from the yellow and red SmartPass wire pair to pin 7 of the DB9 connector or pin 4 of the DB25 connector.
4-9
Page 62
AI1620 SmartPass System Guide
Using RS-422 Interface This section contains instructions for connecting SmartPass to a PC using an RS–422 interface. RS–422 interface signals are supplied by four wires from the SmartPass communications cable. Your host must have an RS–422 interface with either an internal or external converter.
Connecting Colored Wire Pair Cable Table 4-4 shows the RS-422 colored wire assignments. Table 4-4 RS–422 Interface Signal Wiring for Colored Wire Pair Cable Colored Pair Wire Cable Signal from SmartPass
Wire Pair from Color SmartPass
RS–422 Transmit positive
Connect to Signal from Host
Used Yellow
Receive (+)
Red
Receive (–)
Black
Transmit (+)
Red
Transmit (–)
Yellow/Red RS–422 Transmit negative RS–422 Receive positive Red/Black RS–422 Receive negative
To connect the interface, perform the following steps. 1.
Connect the yellow wire (transmit +) from the yellow and red SmartPass wire pair to the host receive (+) signal. Connect the red wire (transmit –) from the yellow and red SmartPass wire pair to the host receive (–) signal.
2.
Connect the black wire (receive +) from the red and black SmartPass wire pair to the host transmit (+) signal.
3.
Connect the red wire (receive –) from the red and black SmartPass wire pair to the host transmit (–) signal.
Using Wiegand Interface This section contains instructions for connecting SmartPass to a PC using a Wiegand interface. Wiegand interface signals are supplied by three wires from the SmartPass communications cable. SmartPass with RS–232 or RS–422 comes with the Wiegand option built in.
4-10
Page 63
Testing and Configuring SmartPass Before Installation
4
To use Wiegand, follow these steps. 1.
Connect SmartPass to the PC, laptop, or terminal emulator using RS–232 connections as described in the section “Using a RS-232 Interface” on page 4-7 or RS –422 connections as described in the section “Using RS-422 Interface” on page 4-10.
2.
If you are using SmartPass Host, select the Communication drop-down menu and click the Wiegand Interface option to configure SmartPass to Wiegand interface. If you are using a terminal emulator, use command 451 to configure SmartPass to Wiegand interface.
3.
Power down the PC.
4.
Disconnect the connection between SmartPass and the PC, laptop, or terminal emulator.
5.
Follow the directions in the section to “Connecting Colored Wire Pair Cable” on page 4-11 connect the interface.
Connecting Colored Wire Pair Cable Table 4-5 shows the Wiegand colored wiring assignments. Table 4-5 Wiegand Interface Signal Wiring for Colored Wire Pair Cable Colored Pair Wire Cable Signal from SmartPass
Wire Pair from Color SmartPass
Wiegand Zero Output
Connect to Signal from Host
Used Blue
Data0
Red
Data1
Yellow or black
Ground
Blue/Red Wiegand One Output Signal Ground
Yellow/Black
To connect the interface, perform the following steps. 1.
Connect the blue wire (data0) from the blue and red SmartPass wire pair to the data0 wire of your Wiegand device.
2.
Connect the red wire (data1) from the blue and red SmartPass wire pair to the data1 wire of your Wiegand device.
3.
Connect either the yellow or black wire from the yellow and black wire SmartPass wire pair to your Wiegand device signal ground.
Note: The RS–232 or RS–422 interface is still included on SmartPass even when you use the Wiegand configuration. Pull the RS–232 red/black wire pairs to a convenient location and tape the ends. Do not cut these wires. If you cut the wires, you may not
4-11
Page 64
AI1620 SmartPass System Guide be able to use them in the future for testing, setting frequency, or adding additional functions.
Default Configuration Settings Before configuring SmartPass for operation at your site, it will be helpful to know the factory default settings.
General Configuration Settings Each SmartPass and its shipping carton are labeled to indicate the unit’s general configuration. Table 4-6 contains explanations of the AI1620 SmartPass configuration fields. Table 4-6 SmartPass Configuration Label Fields
Example:
Field
Description
1st
Model number 1620 915 MHz
2nd
RF Power LO=low RF power (500 mW) HI=high RF power (2000 mW)
3rd
Interface T=RS-232 and Wiegand F=RS-422 and Wiegand
4th
Tag Type 10=access control type tags only 20=ISO read-only full-frame and access control
5th
Antenna Orientation/Tag Polarity H=horizontal tags
General Configuration Settings AI1620 LO T 20 H This SmartPass is configured with low RF power, RS-232 and Wiegand communications, and will read ISO and access control tags mounted horizontally on vehicles.
Operating Parameter Settings Table 4-7 contains the factory default configuration settings for SmartPass operating parameters. Review the default configurations shown in Table 4-7 to determine which parameters will need to be adjusted in addition to operating frequency1 and operating 1.
4-12
Local laws apply. The authorized frequency band in the U.S. is 902 to 904 MHz and 909.75 to 921.75 MHz. Contact Amtech if your application requires a frequency outside of this range.
Page 65
Testing and Configuring SmartPass Before Installation
4 range. Refer to Chapter 7 for a complete list of parameters and their corresponding commands. Table 4-7 SmartPass Default Configuration Settings Parameter
Setting
Command
Operating mode
Data
00
Baud rate
9600
1005
Stop bits
1
1010
Parity
None
1020
End-of-line delay
0 ms
1030a
Time and date appended
Enabled
302
Auxiliary information appended
Disabled
310
Unique ID code criteria
Separation of 1 ID
4100
Valid ID code criteria
1 acquisition
4200a
Uniqueness timeout
2 minutes
441a
Wiegand mode
Disabled
450
Tag translation mode
Disabled
452
Wiegand transmit mode
1 second
4601
Dual processing mode
Reset on A, Transmit on A
4800
Reader ID number
00
6000
Communications protocol
Basic
610
Error correcting protocol (ECP) timeout
12.7 sec
612FE
Flow control
Software (XON/XOFF)
6141
Start-of-message character
# (23 hex)
6150a
Buffer control mode
Disabled
6160
Echo mode
Enabled
6171 sense output control
Predefined
621
RF-by-input control
Enabled
641
RF operating frequency
915 MHz
64200
RF operating range
Maximum
6431F sense output pulse duration
228 ms
67C
4-13
Page 66
AI1620 SmartPass System Guide
Table 4-7 SmartPass Default Configuration Settings (Continued) Parameter
Setting
Command
Presence without tag reports
Disabled
6900
Minimum presence true period
0 ms
6910a
RF-off control
Timeout or no presence
6922
RF timeout
Never true
693F
Input inversion
Disabled
6940
Serial number
NNNNNN
695
Store hardware configuration
Hardware configuration not known
696
Periodic system check tag
Disabled
810
Periodic check tag interval
30 min
8135a
Check tag location
Internal
8160a
Input status change reports
Disabled
820 a. Fixed parameter, set at factory, not user changeable
Configuring Operating Parameters Using Terminal Emulation Software To configure SmartPass using a PC and terminal emulation software to manually enter SmartPass host commands, follow the instructions in the section “Connecting SmartPass to the PC” on page 4-7 to connect SmartPass to a PC. Then, enter the appropriate configuration commands through the terminal emulation software on your PC. You may want to read the section “Configuring Operating Parameters Using SmartPass Host” on page 4-14 to guide you as to which parameters you are likely to need to configure. See Chapter 7 for a detailed description of all available configuration commands.
Configuring Operating Parameters Using SmartPass Host This section describes how to use SmartPass Host to configure SmartPass. SmartPass Host provides an easy-to-use menu to download flash software, configure reader operating parameters, perform diagnostics, and retrieve tag data rather than manually typing in host commands with a terminal emulation software.
4-14
Page 67
Testing and Configuring SmartPass Before Installation
4
Loading and Starting SmartPass Host If SmartPass’s power is not already on, turn on the power. 1.
Insert the SmartPass Host software diskette into the PC disk drive.
2.
OPTIONAL: Open, print, and read the READ.ME file on the diskette.
3.
Start SmartPass Host by performing one of the following. This displays the SmartPass Host status window, shown in Figure 4-3. At the DOS prompt, change the working directory to A:\1620, type dl, and press the ENTER key to start SmartPass Host. OR In Windows, double-click the DL.exe file in the 1620 folder on the A drive.
Command Menu Bar
Status Message Line
Figure 4-3 Status Window
Verifying PC-to-SmartPass Communications Note: When testing SmartPass using a laptop, Amtech recommends that you configure laptop communications parameters to match those of the host computer to which SmartPass will be connected after testing and configuration are completed.
4-15
Page 68
AI1620 SmartPass System Guide
1.
Select the Communication drop-down menu and click the Find Reader option. This displays the Select Option dialog box shown in Figure 4-4.
Figure 4-4 Find Reader Options
2.
Select the Search for Reader option and click the OK. SmartPass Host begins searching for the reader.
If the PC successfully locates SmartPass, SmartPass Host displays the message shown in Figure 4-5. If this message appears, the PC to SmartPass communications are verified.
SmartPass Found Notification
Figure 4-5 Communications Established Message
4-16
Page 69
Testing and Configuring SmartPass Before Installation
4
If the PC is unable to locate SmartPass, SmartPass Host displays the error message shown in Figure 4-6.
SmartPass Not Found Notification
Figure 4-6 Reader Not Found Message
If this message appears; then perform the following procedures.
•
Ensure that all the following communications factors are correct. Change any factors that require it.
•
Verify that SmartPass has power.
•
Verify the connections between the PC and SmartPass.
•
Verify the receive (Rx) and transmit (Tx) connections.
•
Verify the RTS and CTS connections if using handshaking.
•
Verify the COM port settings using the instructions in the section “Serial Port Communications” on page 4-33.
Repeat Steps 1 and 2 above to go through the Communication menu items again. If you still cannot verify the SmartPass and PC communications, use the information in the section “Technical Support” on page 9-7 to contact Amtech.
4-17
Page 70
AI1620 SmartPass System Guide
Verifying Tag Read Capability After establishing communications between SmartPass and the PC, test the capability to read tags by performing the following steps. 1.
Pass one test tag in front of the unit. If SmartPass reads the tag, SmartPass Host displays the tag information at the bottom of the status window, as shown in Figure 4-7.
Successful Tag Read
Figure 4-7 Successful Tag Read
If the read is unsuccessful, try the following actions:
•
Be sure the red/green pair are still twisted together as described in the section “Testing Using an Audible Circuit Tester” on page 4-2.
•
Ensure the tag you are using is compatible with the particular option of SmartPass you are working with. Some SmartPasses cannot read full-frame tags. To determine if the SmartPass you are working with can read full-frame tags, refer to the section “General Configuration Settings” on page 4-12 for information on reading the configuration label. A SmartPass could have a label such as the following: AI1620 HI T 10 H where the 10 indicates it can read only access control tags, not full-frame tags.
•
2.
4-18
Using the audible circuit tester, verify that the reader is capable of reading the tag in the read zone. If it is, the problem is probably in the communications between SmartPass and the host. Pass a different test tag in front of your SmartPass.