Page 61

Testing and Configuring SmartPass Before Installation

4

Connecting Colored Wire Pair Cable Table 4-3 shows the RS-232 colored wire assignments. Table 4-3 RS–232 Interface Signal Wiring for Colored Wire Pair Cable Colored Pair Wire Cable Signal from SmartPass

Connect Wire to Host DB9 Pin

Connect Wire to Host DB25 Pin

Black

Pin 2

Pin 3

Red

Pin 3

Pin 2

Yellow or black

Pin 5

Pin 7

Yellow

Pin 8

Pin 5

Red

Pin 7

Pin 4

Wire Pair from Color SmartPass

TxD, SmartPass output

Used

Red/Black RxD, SmartPass input Signal ground

Yellow/ Black

Optional for hardware handshaking RTS, SmartPass output Yellow/Red CTS, SmartPass input

To connect the interface, perform the following steps. 1.

Connect the black wire (transmit data) from the red and black SmartPass wire pair to pin 2 of the DB9 connector or pin 3 of the DB25 connector.

2.

Connect the red wire (receive data) from the red and black SmartPass wire pair to pin 3 of the DB9 connector or pin 2 of the DB25 connector.

3.

Connect either the yellow or black wire (logic ground) from the yellow and black SmartPass wire pair to pin 5 of the DB9 connector or pin 7 of the DB25 connector.

4.

Plug the DB9 connector or DB25 connector into the PC.

If the host is set up for hardware handshaking, use the following procedures. 5.

Connect the yellow wire (RTS) from the yellow and red SmartPass wire pair to pin 8 of the DB9 connector or pin 5 of the DB25 connector.

6.

Connect the red wire (CTS) from the yellow and red SmartPass wire pair to pin 7 of the DB9 connector or pin 4 of the DB25 connector.

4-9

Page 62

AI1620 SmartPass System Guide

Using RS-422 Interface This section contains instructions for connecting SmartPass to a PC using an RS–422 interface. RS–422 interface signals are supplied by four wires from the SmartPass communications cable. Your host must have an RS–422 interface with either an internal or external converter.

Connecting Colored Wire Pair Cable Table 4-4 shows the RS-422 colored wire assignments. Table 4-4 RS–422 Interface Signal Wiring for Colored Wire Pair Cable Colored Pair Wire Cable Signal from SmartPass

Wire Pair from Color SmartPass

RS–422 Transmit positive

Connect to Signal from Host

Used Yellow

Receive (+)

Red

Receive (–)

Black

Transmit (+)

Red

Transmit (–)

Yellow/Red RS–422 Transmit negative RS–422 Receive positive Red/Black RS–422 Receive negative

To connect the interface, perform the following steps. 1.

Connect the yellow wire (transmit +) from the yellow and red SmartPass wire pair to the host receive (+) signal. Connect the red wire (transmit –) from the yellow and red SmartPass wire pair to the host receive (–) signal.

2.

Connect the black wire (receive +) from the red and black SmartPass wire pair to the host transmit (+) signal.

3.

Connect the red wire (receive –) from the red and black SmartPass wire pair to the host transmit (–) signal.

Using Wiegand Interface This section contains instructions for connecting SmartPass to a PC using a Wiegand interface. Wiegand interface signals are supplied by three wires from the SmartPass communications cable. SmartPass with RS–232 or RS–422 comes with the Wiegand option built in.

4-10

Page 63

Testing and Configuring SmartPass Before Installation

4

To use Wiegand, follow these steps. 1.

Connect SmartPass to the PC, laptop, or terminal emulator using RS–232 connections as described in the section “Using a RS-232 Interface” on page 4-7 or RS –422 connections as described in the section “Using RS-422 Interface” on page 4-10.

2.

If you are using SmartPass Host, select the Communication drop-down menu and click the Wiegand Interface option to configure SmartPass to Wiegand interface. If you are using a terminal emulator, use command 451 to configure SmartPass to Wiegand interface.

3.

Power down the PC.

4.

Disconnect the connection between SmartPass and the PC, laptop, or terminal emulator.

5.

Follow the directions in the section to “Connecting Colored Wire Pair Cable” on page 4-11 connect the interface.

Connecting Colored Wire Pair Cable Table 4-5 shows the Wiegand colored wiring assignments. Table 4-5 Wiegand Interface Signal Wiring for Colored Wire Pair Cable Colored Pair Wire Cable Signal from SmartPass

Wire Pair from Color SmartPass

Wiegand Zero Output

Connect to Signal from Host

Used Blue

Data0

Red

Data1

Yellow or black

Ground

Blue/Red Wiegand One Output Signal Ground

Yellow/Black

To connect the interface, perform the following steps. 1.

Connect the blue wire (data0) from the blue and red SmartPass wire pair to the data0 wire of your Wiegand device.

2.

Connect the red wire (data1) from the blue and red SmartPass wire pair to the data1 wire of your Wiegand device.

3.

Connect either the yellow or black wire from the yellow and black wire SmartPass wire pair to your Wiegand device signal ground.

Note: The RS–232 or RS–422 interface is still included on SmartPass even when you use the Wiegand configuration. Pull the RS–232 red/black wire pairs to a convenient location and tape the ends. Do not cut these wires. If you cut the wires, you may not

4-11

Page 64

AI1620 SmartPass System Guide be able to use them in the future for testing, setting frequency, or adding additional functions.

Default Configuration Settings Before configuring SmartPass for operation at your site, it will be helpful to know the factory default settings.

General Configuration Settings Each SmartPass and its shipping carton are labeled to indicate the unit’s general configuration. Table 4-6 contains explanations of the AI1620 SmartPass configuration fields. Table 4-6 SmartPass Configuration Label Fields

Example:

Field

Description

1st

Model number 1620 915 MHz

2nd

RF Power LO=low RF power (500 mW) HI=high RF power (2000 mW)

3rd

Interface T=RS-232 and Wiegand F=RS-422 and Wiegand

4th

Tag Type 10=access control type tags only 20=ISO read-only full-frame and access control

5th

Antenna Orientation/Tag Polarity H=horizontal tags

General Configuration Settings AI1620 LO T 20 H This SmartPass is configured with low RF power, RS-232 and Wiegand communications, and will read ISO and access control tags mounted horizontally on vehicles.

Operating Parameter Settings Table 4-7 contains the factory default configuration settings for SmartPass operating parameters. Review the default configurations shown in Table 4-7 to determine which parameters will need to be adjusted in addition to operating frequency1 and operating 1.

4-12

Local laws apply. The authorized frequency band in the U.S. is 902 to 904 MHz and 909.75 to 921.75 MHz. Contact Amtech if your application requires a frequency outside of this range.

Page 65

Testing and Configuring SmartPass Before Installation

4 range. Refer to Chapter 7 for a complete list of parameters and their corresponding commands. Table 4-7 SmartPass Default Configuration Settings Parameter

Setting

Command

Operating mode

Data

00

Baud rate

9600

1005

Stop bits

1

1010

Parity

None

1020

End-of-line delay

0 ms

1030a

Time and date appended

Enabled

302

Auxiliary information appended

Disabled

310

Unique ID code criteria

Separation of 1 ID

4100

Valid ID code criteria

1 acquisition

4200a

Uniqueness timeout

2 minutes

441a

Wiegand mode

Disabled

450

Tag translation mode

Disabled

452

Wiegand transmit mode

1 second

4601

Dual processing mode

Reset on A, Transmit on A

4800

Reader ID number

00

6000

Communications protocol

Basic

610

Error correcting protocol (ECP) timeout

12.7 sec

612FE

Flow control

Software (XON/XOFF)

6141

Start-of-message character

# (23 hex)

6150a

Buffer control mode

Disabled

6160

Echo mode

Enabled

6171 sense output control

Predefined

621

RF-by-input control

Enabled

641

RF operating frequency

915 MHz

64200

RF operating range

Maximum

6431F sense output pulse duration

228 ms

67C

4-13

Page 66

AI1620 SmartPass System Guide

Table 4-7 SmartPass Default Configuration Settings (Continued) Parameter

Setting

Command

Presence without tag reports

Disabled

6900

Minimum presence true period

0 ms

6910a

RF-off control

Timeout or no presence

6922

RF timeout

Never true

693F

Input inversion

Disabled

6940

Serial number

NNNNNN

695

Store hardware configuration

Hardware configuration not known

696

Periodic system check tag

Disabled

810

Periodic check tag interval

30 min

8135a

Check tag location

Internal

8160a

Input status change reports

Disabled

820 a. Fixed parameter, set at factory, not user changeable

Configuring Operating Parameters Using Terminal Emulation Software To configure SmartPass using a PC and terminal emulation software to manually enter SmartPass host commands, follow the instructions in the section “Connecting SmartPass to the PC” on page 4-7 to connect SmartPass to a PC. Then, enter the appropriate configuration commands through the terminal emulation software on your PC. You may want to read the section “Configuring Operating Parameters Using SmartPass Host” on page 4-14 to guide you as to which parameters you are likely to need to configure. See Chapter 7 for a detailed description of all available configuration commands.

Configuring Operating Parameters Using SmartPass Host This section describes how to use SmartPass Host to configure SmartPass. SmartPass Host provides an easy-to-use menu to download flash software, configure reader operating parameters, perform diagnostics, and retrieve tag data rather than manually typing in host commands with a terminal emulation software.

4-14

Page 67

Testing and Configuring SmartPass Before Installation

4

Loading and Starting SmartPass Host If SmartPass’s power is not already on, turn on the power. 1.

Insert the SmartPass Host software diskette into the PC disk drive.

2.

OPTIONAL: Open, print, and read the READ.ME file on the diskette.

3.

Start SmartPass Host by performing one of the following. This displays the SmartPass Host status window, shown in Figure 4-3. At the DOS prompt, change the working directory to A:\1620, type dl, and press the ENTER key to start SmartPass Host. OR In Windows, double-click the DL.exe file in the 1620 folder on the A drive.

Command Menu Bar

Status Message Line

Figure 4-3 Status Window

Verifying PC-to-SmartPass Communications Note: When testing SmartPass using a laptop, Amtech recommends that you configure laptop communications parameters to match those of the host computer to which SmartPass will be connected after testing and configuration are completed.

4-15

Page 68

AI1620 SmartPass System Guide

1.

Select the Communication drop-down menu and click the Find Reader option. This displays the Select Option dialog box shown in Figure 4-4.

Figure 4-4 Find Reader Options

2.

Select the Search for Reader option and click the OK. SmartPass Host begins searching for the reader.

If the PC successfully locates SmartPass, SmartPass Host displays the message shown in Figure 4-5. If this message appears, the PC to SmartPass communications are verified.

SmartPass Found Notification

Figure 4-5 Communications Established Message

4-16

Page 69

Testing and Configuring SmartPass Before Installation

4

If the PC is unable to locate SmartPass, SmartPass Host displays the error message shown in Figure 4-6.

SmartPass Not Found Notification

Figure 4-6 Reader Not Found Message

If this message appears; then perform the following procedures.

•

Ensure that all the following communications factors are correct. Change any factors that require it.

•

Verify that SmartPass has power.

•

Verify the connections between the PC and SmartPass.

•

Verify the receive (Rx) and transmit (Tx) connections.

•

Verify the RTS and CTS connections if using handshaking.

•

Verify the COM port settings using the instructions in the section “Serial Port Communications” on page 4-33.

Repeat Steps 1 and 2 above to go through the Communication menu items again. If you still cannot verify the SmartPass and PC communications, use the information in the section “Technical Support” on page 9-7 to contact Amtech.

4-17

Page 70

AI1620 SmartPass System Guide

Verifying Tag Read Capability After establishing communications between SmartPass and the PC, test the capability to read tags by performing the following steps. 1.

Pass one test tag in front of the unit. If SmartPass reads the tag, SmartPass Host displays the tag information at the bottom of the status window, as shown in Figure 4-7.

Successful Tag Read

Figure 4-7 Successful Tag Read

If the read is unsuccessful, try the following actions:

•

Be sure the red/green pair are still twisted together as described in the section “Testing Using an Audible Circuit Tester” on page 4-2.

•

Ensure the tag you are using is compatible with the particular option of SmartPass you are working with. Some SmartPasses cannot read full-frame tags. To determine if the SmartPass you are working with can read full-frame tags, refer to the section “General Configuration Settings” on page 4-12 for information on reading the configuration label. A SmartPass could have a label such as the following: AI1620 HI T 10 H where the 10 indicates it can read only access control tags, not full-frame tags.

•

2.

4-18

Using the audible circuit tester, verify that the reader is capable of reading the tag in the read zone. If it is, the problem is probably in the communications between SmartPass and the host. Pass a different test tag in front of your SmartPass.