Page 51
Choosing, Installing, and Removing Tags
3
Installation Procedures Using Tape Perform the following steps to install the tag on a metal or plastic bumper: 1.
Clean and degrease the tag installation area of the vehicle bumper with solvent/ cleaner.
2.
Dry the area thoroughly using a clean, dry cloth.
3.
Remove the backing from the double-sided tape on the back of the tag, as shown in Figure 3-5.
Figure 3-5 Exterior Tag with Double-Sided Tape
4.
Position the tag over the installation area, making sure that the tag and SmartPass orientation are the same (horizontal or vertical).
5.
Press the tag firmly against the bumper.
Installation Procedures Using Blind Rivets Follow the steps below to install an exterior tag using blind rivets through the tag’s installation tabs: 1.
Position the tag on the bumper in the installation area and mark the hole positions of the tag’s installation tabs onto the bumper.
2.
Follow the rivet manufacturer’s instructions to drill holes in the bumper for rivets.
3.
If the rivet head is smaller than the tag installation holes and can be pulled through the holes, use a small washer to secure the rivet through the tag.
Removing Exterior Tags To remove an exterior tag installed with rivets, follow the rivet manufacturer’s instructions to remove the rivets.
3-11
Page 52
AI1620 SmartPass System Guide
3-12
Page 53
4 Testing and Configuring SmartPass Before Installation
Page 54
Page 55
Testing and Configuring SmartPass Before Installation
4
This chapter provides instructions for testing and configuring SmartPass. These tasks are best performed before you permanently install SmartPass at the site. The chapter includes the following information: • Materials needed to perform the test and configure SmartPass
•
How to use an audible circuit tester to confirm that SmartPass has power, is communicating with the host software, and can read a tag presented in the tag read zone
•
How to use the SmartPass Host v2.01 on the SmartPass software diskette (DL.EXE) to check the SmartPass factory configuration defaults and change the configuration parameters, if necessary
Materials Required You will need the following materials to test and configure SmartPass. Amtech supplies some of the materials; other materials must be obtained from other sources.
Materials Supplied Your SmartPass is packaged with the following materials. Ensure that you have received all parts before beginning your pre-installation SmartPass tests.
•
One SmartPass
•
One mounting bracket and mounting hardware
Cable Supplied SmartPass may be ordered (as a separate accessory) with a multiwire cable, which is a 13-pair pigtail. The 13-pair pigtail is a colored wire pair cable, with different colors denoting the individual pairs, one pair of which is red/black. In some instances, an alternate 15-pair pigtail may be substituted. The alternate cable is a red/black wire pair cable, with numbers on the pairs to denote the individual pairs. Two pairs of the 15-pair pigtail, numbers 14 and 15, are not used. Refer to Appendix C for alternate cable wiring diagrams.
4-3
Page 56
AI1620 SmartPass System Guide
Additional Materials Needed You will need these additional materials to perform the two tests on SmartPass:
•
One step-down transformer or other suitable low voltage power source
•
SmartPass software diskette, which is supplied to Amtech dealers and distributors, or any terminal program running on a PC
•
PC or laptop with 1.44 MB floppy disk drive, MS DOS, RS–232 serial port, and a communications cable with a DB9 or DB25 connector
•
Two test tags, supplied by the Amtech dealer or distributor
•
Communications cable to connect to the COM1 or COM2 port on your PC
•
Suitable 18 V AC or 18 V DC power wiring for the SmartPass
•
Audible circuit tester and 9 V DC battery for circuit tester power
•
Wire stripper
•
Printer (optional) to print out the READ.ME file from the download software diskette
Testing Using an Audible Circuit Tester Testing with an audible circuit tester will confirm that your SmartPass has power, has the software downloaded properly to it, is communicating with the host software, and can read a tag presented in the read zone. An audible circuit tester is also called a buzz box. These boxes are available at some electronic parts supply stores, or you can make a buzz box, as shown in Figure 4-1.
4-4
Page 57
Testing and Configuring SmartPass Before Installation
4
The buzz box is powered by a 9 V DC battery and is equipped with two alligator-clip leads. When you touch the leads together, the box makes an audible sound.
Figure 4-1 Wiring for Audible Circuit Tester
To test SmartPass, connect the power supply as described in the appropriate section below, and then test as described in the section “Testing SmartPass” on page 4-6.
Connecting the AC Power Supply To connect SmartPass to a low-voltage AC power supply, perform the following steps. 1.
Connect the SmartPass power wires from the cable to the transformer using the color coding as described in Table 4-1.
Table 4-1 AC Transformer Connections for Colored Pair Wire Cable Colored Pair Wire Cable Signal From SmartPass
Wire Pair from Color SmartPass
Main power input Main power return
2.
Brown/Red and Orange/Red
Connect to Transformer Terminal Strip
Used Orange and Brown
L1
Red and Red
L2
Complete the power connections at the power supply.
4-5
Page 58
AI1620 SmartPass System Guide
Connecting the DC Power Supply To install SmartPass using low voltage DC connections, use the connection designations shown in Table 4-2. Table 4-2 Low Voltage DC Cable Connections for the Colored Pair Wire Cable Colored Pair Wire Cable Signal from SmartPass
Wire Pair from Color SmartPass
Main power input Main power return
Brown/Red and Orange/Red
Connection Use
Used Orange and Brown
16 to 28 V DC + terminal
Red and Red
16 to 28 V DC – terminal
Testing SmartPass To test that SmartPass has power and can read a tag presented in the read zone, perform the following steps. 1.
Connect the two leads from the audible circuit tester to the white and red wire pair (pair #8, lock/lock return) from the SmartPass cable.
2.
Twist the red and green wire pair (pair #9, sense input0/sense input0 return) from the SmartPass cable to turn on a continuous RF signal.
3.
Pass a tag in front of SmartPass. The audible circuit tester should sound a tone when the tag is read.
4.
Disconnect the circuit tester from SmartPass.
Note: You will need the audible circuit tester again to determine the read zone when installing SmartPass at the site.
4-6
Page 59
Testing and Configuring SmartPass Before Installation
4
Configuring SmartPass After testing SmartPass, you will need to configure its operating parameters before permanently installing it at the site. Two methods are available for configuring SmartPass:
•
Use a PC and terminal emulation software to enter the host commands. (Terminal settings should be initially set at 9600 baud, 8 data bits, no parity, 1 stop bit, and flow control = none)
•
Use a PC and SmartPass Host, provided on the Amtech SmartPass software diskette.
Connecting SmartPass to the PC This section contains instructions for connecting RS-232, RS-422, and Wiegand communications between SmartPass and the PC. Each section contains wiring instructions and pin assignments followed by step-by-step connection procedures.
Using a RS-232 Interface This section contains instructions for connecting SmartPass to a PC using an RS–232 interface. RS–232 interface signals are supplied by five wires from the SmartPass communications cable. The pin assignments for the signal to the host for male DB9 and DB25 connectors are shown in Figure 4-2.
4-7
Page 60
AI1620 SmartPass System Guide
Figure 4-2 DB9 and DB25 Connector Pin Assignments for Signal to Host
4-8