Page 171

Installing SmartPass

8

Connecting the AC Power Supply To connect SmartPass to a low-voltage AC power supply, perform the following steps. 1. Connect the SmartPass power wires from the cable to the transformer using the cable coding as described in Table 8-3. Table 8-3 AC Transformer Connections for Colored Pair Wire Cable Colored Pair Wire Cable Signal From SmartPass

Wire Pair from Color

Connect to Transformer Terminal Strip

SmartPass Used Main power input Main power return

2.

Brown/Red and Orange/Red

Brown and Orange

L1

Red and Red

L2

Complete the power connections at the power supply.

8-13

Page 172

AI1620 SmartPass System Guide

Connecting the DC Power Supply To install SmartPass using low voltage DC connections, use the connection designations shown in Table 8-4. Table 8-4 Low Voltage DC Cable Connections for the Colored Pair Wire Cable Colored Pair Wire Cable Signal from SmartPass

Wire Pair from Color

Connection Use

SmartPass Used Main power input Main power return

Brown/Red and Orange/Red

Brown and Orange

16 to 28 V DC + terminal

Red and Red

16 to 28 V DC – terminal

Marking the Read Zone The antenna pattern, or read zone, of SmartPass would look roughly like a pearshaped balloon if you were able to see it. When installing SmartPass, you will first mark the unit’s read zone with the RF range set at the factory default maximum. You can then adjust the read zone using the techniques discussed in “Fine-Tuning and Verifying the Read Zone” on page 8-16. If two SmartPass readers are installed near each other, Amtech recommends that you fine-tune each SmartPass for the ideal read zone before connecting it to permanent sense input/sense output and communications cables.

Materials Required To mark the read zone, you will need the following items:

8-14

•

SmartPass software diskette, which is supplied to Amtech dealers and distributors, or any terminal program running on a PC

•

PC or laptop with 1.44 MB floppy disk drive, MS-DOS, RS–232 serial port, and a communications cable with a DB9 or DB25 connector

•

Test tag, supplied by the Amtech dealer or distributor

•

Communications cable to connect to the COM1 port on your PC

Page 173

Installing SmartPass

8

•

Audible circuit tester and 9 V DC battery for circuit tester power as described in the section, “Testing SmartPass” on page 4-6.

•

Piece of chalk or roll of tape

•

Plastic or wooden yardstick

•

Vinyl electrical tape or hook-and-loop material

Marking Procedures Follow the steps below to mark the read zone: 1. Connect the red and white leads from the audible tester to the red and white pair of wires from the SmartPass cable. 2.

Twist together the red and green pair of wires from the SmartPass cable to turn on continuous RF power.

3.

Secure the test tag to the end of the yardstick using electrical tape or hook-andloop material. Be sure the tag polarization matches that of the SmartPass when the yardstick is held upright.

4.

Stand directly in front of and about 5 ft (1.5 m) away from SmartPass. Hold the stick so that the tag is positioned at a height and angle consistent with a tag installed on a vehicle. The test tag should cause the audible tester to sound.

Note: If you hold the test tag in your hand, your hand will absorb the RF signal and the test results will be incorrect. 5.

Move to the left until the sound stops.

6.

Mark the ground with chalk or tape at the location of the tag when the sound stopped.

7.

Step backward 1 to 2 ft (0.3 to 0.6 m) and repeat Steps 5 and 6.

8.

Continue moving the tag back and forth in this manner, placing marks on the ground to identify the boundary of the read zone each time the sound stops. Continue moving the tag to various locations until the read zone is fully marked. The marks on the ground will indicate the area, called the read zone, where SmartPass reads tags at the current RF range. Figure 8-10 is a view of an ideal read

8-15

Page 174

AI1620 SmartPass System Guide zone within a controlled lane. The x marks show the outside edges of the read zone.

Figure 8-10 Sample Read Zone Marking Pattern

9.

Standing at the farthest point of the pattern, walk toward SmartPass and listen for a continuous sound from the audible tester. If the sound is not continuous, it could indicate a weak or “patchy” RF pattern. See the section, “Fine-Tuning and Verifying the Read Zone” on page 8-16, to adjust the read zone.

Fine-Tuning and Verifying the Read Zone If the read zone is too wide or too deep, it can be fine-tuned by changing the angle of SmartPass or by changing the RF range. Physically adjusting SmartPass and changing the RF range can confine the read zone to the area of the single lane where tagged vehicles are expected to pass. Fine-tuning the read zone also helps prevent SmartPass from reading tagged vehicles in adjacent lanes or parked behind or next to a SmartPass unit. You can make the read zone smaller by adjusting the RF range down from the factory default (maximum range). The range can be adjusted through a host command or using SmartPass Host.

8-16

Page 175

Installing SmartPass

8

Use the following procedure to adjust the RF range using SmartPass Host, included on the software diskette supplied to dealers and distributors. 1. Connect the laptop PC to SmartPass and load SmartPass Host, as discussed in “Connecting SmartPass to the PC” on page 4-7, and “Loading and Starting SmartPass Host” on page 4-15. 2.

Have another person hold the test tag at the farthest distance at which you want SmartPass to read a tag.

3.

Select the Tag & RF drop-down menu and click on the RF Range command. This displays the Range Value dialog box, as shown in Figure 8-11.

Figure 8-11 Range Value Dialog Box

4.

Type in a value from 0 to 31, with 31 being the maximum (default). Smaller entries decrease the read zone size; larger entries increase the read zone size. Click on the OK button to make the change.

5.

Follow the steps in the section, “Marking Procedures” on page 8-15, to mark the new read zone on the ground with the tape or chalk.

6.

With SmartPass Host running, place one tag behind your back while you hold another tag in the read zone. If a good read is accomplished, the data from the tag held in the read zone will be displayed on the PC screen.

7.

Switch tags, placing the other tag behind your back and holding the first tag in the read zone. If a good read is accomplished, the data from this tag held in the read zone will be displayed on the PC screen.

8.

If both tags read successfully, you are ready to connect communications to the junction box terminal. If one or both tags did not read, follow the suggestions in the ‘Verifying Tag Read Capability’ section on page 4-20.

8-17

Page 176

AI1620 SmartPass System Guide

9.

As a last test, attach test tags to vehicles and simulate traffic going through the read zone to verify that the system performs accurately in a live environment.

Connecting Communications Amtech offers reader communications through RS–232, RS–422, and Wiegand interface protocols. This section provides the procedures for connecting the communications to the junction box and to the sense input and sense output circuits. Before connecting the SmartPass communications cable to the junction box, Amtech recommends that you test and configure SmartPass hardware and software as presented in Chapter 4, “Testing and Configuring SmartPass Before Installation.” All the wiring tables are also shown in Appendix C, “Wiring Tables.”

Connecting SmartPass to the PC SmartPass communications and customer interface signals are supplied from SmartPass to the host through a multiwire cable, which is a 13- or 15-pair pigtail. The connector for this cable is located on the back of SmartPass. Refer to the following sections to connect the appropriate wires from the communications cable to the terminal strip that is located inside the junction box. This section contains instructions for connecting RS-232, RS-422, and Wiegand communications between SmartPass and the PC. Each section contains wiring instructions and pin assignments followed by step-by-step connection procedures. SmartPass does not need to be powered down before attaching it to the PC.

Using a RS-232 Interface This section contains instructions for connecting SmartPass to a PC using an RS–232 interface. RS–232 interface signals are supplied by five wires from the SmartPass communications cable. The pin assignments for the signal to the host male DB9 and DB25 connectors are shown in Figure 8-12.

8-18

Page 177

Installing SmartPass

8

Figure 8-12 DB9 and DB25 Connector Pin Assignments for Signal to Host

Connecting Colored Wire Pair Cable Table 8-5 shows the RS-232 colored wire assignments. Table 8-5 RS–232 Interface Signal Wiring for Colored Wire Pair Cable Colored Pair Wire Cable Signal from SmartPass

Connect Wire to Host DB9 Pin

Connect Wire to Host DB25 Pin

Black

Pin 2

Pin 3

Red

Pin 3

Pin 2

Yellow or black

Pin 5

Pin 7

Wire Pair from Color SmartPass Used

TxD, SmartPass sense output, host sense input RxD, SmartPass sense input, host sense output Signal ground

Red/Black

Yellow/ Black

8-19

Page 178

AI1620 SmartPass System Guide

Table 8-5 RS–232 Interface Signal Wiring for Colored Wire Pair Cable Optional for hardware handshaking RTS, SmartPass sense output, host sense input

Yellow

Pin 8

Pin 5

Red

Pin 7

Pin 4

Yellow/Red CTS, SmartPass sense input, host sense output

1.

Connect the black wire (transmit data) from the red and black SmartPass wire pair to pin 2 of the DB9 connector or pin 3 of the DB25 connector.

2.

Connect the red wire (receive data) from the red and black SmartPass wire pair to pin 3 of the DB9 connector or pin 2 of the DB25 connector.

3.

Connect either the yellow or black wire (logic ground) from the yellow and black SmartPass wire pair to pin 5 of the DB9 connector or pin 7 of the DB25 connector.

4.

Plug the DB9 connector or DB25 connector into the PC.

If the host is set up for hardware handshaking, use the following procedures. 1.

Connect the yellow wire (RTS) from the yellow and red SmartPass wire pair to pin 8 of the DB9 connector or pin 5 of the DB25 connector.

2.

Connect the red wire (CTS) from the yellow and red SmartPass wire pair to pin 7 of the DB9 connector or pin 4 of the DB25 connector.

Using RS-422 Interface This section contains instructions for connecting SmartPass to a PC using an RS–422 interface. RS–422 interface signals are supplied by four wires from the SmartPass communications cable. Your host must have an RS–422 interface with either an internal or external converter.

8-20

Page 179

Installing SmartPass

8

Connecting Colored Wire Pair Cable Table 8-6 lists the RS–422 signals and their interface wires. Table 8-6 RS–422 Interface Signal Wiring for Colored Wire Pair Cable Colored Pair Wire Cable Signal from SmartPass

Wire Pair from Color

Connect to Signal from Host

SmartPass Used RS–422 Transmit positive

Yellow

Receive (+)

Red

Receive (–)

Black

Transmit (+)

Red

Transmit (–)

Yellow/Red RS–422 Transmit negative RS–422 Receive positive Red/Black RS–422 Receive negative

To connect the interface perform the following steps. 1. Connect the yellow wire (transmit +) from the yellow and red SmartPass wire pair to the host receive (+) signal. 2.

Connect the red wire (transmit –) from the yellow and red SmartPass wire pair to the host receive (–) signal.

3.

Connect the black wire (receive +) from the red and black SmartPass wire pair to the host transmit (+) signal.

4.

Connect the red wire (receive –) from the red and black SmartPass wire pair to the host transmit (–) signal.

Using Wiegand Interface This section contains instructions for connecting SmartPass to a PC using a Wiegand interface. Wiegand interface signals are supplied by three wires from the SmartPass communications cable.

SmartPass with RS–232 or RS–422 comes with the Wiegand option built in. To use Wiegand, follow these steps. 1. Connect SmartPass to the PC, laptop, or terminal emulator using RS–232 connections as described in the ‘Using a RS-232 Interface’ section on 8-18 or RS–422 connections as described in the ‘Using RS-422 Interface’ section on 820. 2.

If you are using SmartPass Host, select the Communication drop-down menu and click the Wiegand Interface option to configure SmartPass to Wiegand interface.

8-21

Page 180

AI1620 SmartPass System Guide

If you are using a terminal emulator, use command 451 to configure SmartPass to Wiegand interface. 1. Power down the PC. 2.

Disconnect the connection between SmartPass and the PC, laptop, or terminal emulator.

3.

Follow the directions in the “Connecting Colored Wire Pair Cable” on page 8-22 to connect the interface.

Connecting Colored Wire Pair Cable Table 8-7 lists the Wiegand signals and the interface wires. Table 8-7 Wiegand Interface Signal Wiring for Colored Wire Pair Cable Colored Pair Wire Cable Signal from SmartPass

Wire Pair from Color

Connect to Signal from Host

SmartPass Used Wiegand Zero Output

Blue

Data0

Red

Data1

Yellow or black

Ground

Blue/Red Wiegand One Output Signal Ground

Yellow/Black

To connect the interface perform the following steps. 1. Connect the blue wire (data0) from the blue and red SmartPass wire pair to the data0 wire of your Wiegand device. 2.

Connect the red wire (data1) from the blue and red SmartPass wire pair to the data1 wire of your Wiegand device.

3.

Connect either the yellow or black wire from the yellow and black wire SmartPass wire pair to your Wiegand device logic ground.

Note: The RS–232 or RS–422 interface is still included on SmartPass even when you use the Wiegand configuration. Pull the RS–232 red/black wire pairs to a convenient location and tape the ends. Do not cut these wires. If you cut the wires, you may not be able to use them in the future for testing, setting frequency, or adding additional functions.

Connecting Sense Input and Sense Output Circuits SmartPass has two sense input circuits and three sense output circuits available. The sense input circuits can be used to notify SmartPass of external events and are designed to be connected to a free-of-voltage dry contact. Sense output circuits are single-pole, double-throw relays that provide normally closed and normally open dry contacts.

8-22