Page 181

Installing SmartPass

8

The following sections provide information to connect the sense input and sense output circuits.

Connecting Sense Input Circuits SmartPass supports two sense inputs, sense input0 and sense input1. This requires two sense input lines for each loop sense or a total of four sense input connections. Sense input0 is the presence detection device line and is used to control RF power. Sense input0 is through the green/red wire pair on the I/O pigtail. SmartPass expects the sense input0 circuit to close when a vehicle is present (i.e., a normally open condition). The minimum presence true period is fixed at 0 ms, which indicates that no delay occurs in closing the circuit when a vehicle is present. Sense input1 is not used directly by SmartPass. Sense input1 is under the host computer’s control.

Connecting Sense Output Circuits SmartPass supports three sets of sense output signals. Two sets (sense output0 and sense output1) provide normally open or normally closed sense outputs. The third sense output set is dedicated for testing and setup of the reader. It is defined as the TAG_LOCK signal, which indicates when a valid tag is in the read field. These sense outputs are dry contacts that provide normally open and normally closed sense outputs. The relay contacts are rated at 30 Vrms or 60 V DC at 1 A, maximum. As illustrated in Figure 8-13, sense output0, normally closed, is located on the orange/ black pair. Sense output0, normally open, is located on the brown/black pair.

Figure 8-13 Sample Circuit Connections

In Wiegand mode operation, the sense outputs are not controlled by a predefined output mode.

8-23

Page 182

AI1620 SmartPass System Guide

Table 8-8 lists the cable descriptions and functions for the interface signals. These wire pairs can be used or terminated based on the specific project applications. Connect the remaining wires to the appropriate terminal blocks on the terminal strip in the junction box. As a guide to the functions of each of the wire signals, use Table 8-8 if SmartPass has the colored wire pair cable. Table 8-8 Sense Input/Output Cabling Assignments for Colored Wire Pair Cable Pair

Pin

Color

Signal

Description

Typical Function

Blue/ Red

E

Blue

WGND0

Wiegand data0

Parking/access control applications

F

Red

WGND1

Wiegand data1

Parking/access control applications

L

White

Lock

Tag lock output, active-closed

Testing maintenance

M

Red

Lock_RTN

Tag lock return

Testing maintenance

N

Green

Sense Input0

Sense Input0 (loop)

Loop and presence detect

P

Red

Sense Input0_RTN

Sense Input0 return; not isolated from signal ground

Loop and presence detect

R

Blue

Sense Input1

Sense Input1

General-purpose sense input, not used to detect presence.

S

Black

Sense Input1_RTN

Sense Input1 return; not isolated from signal ground

General-purpose sense input, not used to detect presence.

T

Black

Out0_COM

Sense Output0 (tag detect), common terminal

Switched output to control gate

U

Brown

Out0_No

Sense Output0 normally open terminal

Switched output to control gate

V

Black

Out0_COM

Sense Output0 (tag detect output), common terminal

Switched sense output for any external control (light, gate, buzzer, etc.)

White/ Red

Green/ Red

Blue/ Black

Brown/ Black

Orang e/Black

8-24

Page 183

Installing SmartPass

8

Table 8-8 Sense Input/Output Cabling Assignments for Colored Wire Pair Cable Pair

Green/ Black

White/ Black

Yellow/ Black

Pin

Color

Signal

Description

Typical Function

W

Orange

Out 0 Normally Closed

Sense Output0 normally closed terminal

Switched sense output for any external control (light, gate, buzzer, etc.)

X

Black

Out1_ COM

Sense Output1, common terminal

Switched sense output

Y

Green

Out1_NO

Sense Output1 normally open terminal

Switched sense output

Z

Black

Out1_ COM

Sense Output1, common

Switched sense output a

White

Out1_NO

Sense Output1 normally closed terminal

Switched sense output b

Yellow

GND logic ground

Signal ground (used with RS232 and Wiegand c

Black

GND logic ground

Signal ground (used with RS232 and Wiegand

Caution After connecting the wires in the communications cable, ground all drain wires from the communications cable to the chassis ground in the NEMA enclosure.

8-25

Page 184

AI1620 SmartPass System Guide

8-26

Page 185

9 Troubleshooting and Maintenance

Page 186

This page is a scan with no text; see it in the PDF.

Page 187

Troubleshooting and Maintenance

9

This chapter includes information for troubleshooting SmartPass and performing minimal maintenance checks. It also includes information for returning products for repair, obtaining support, and a contact for providing feedback and suggestions to Amtech.

Error Messages SmartPass transmits an error message if a command received from the host is not a recognized command, or if information supplied with the command is not correct. The reader sends this message to diagnostic commands if the reader fails the specified test. Table 9-1 contains a list of error messages. Messages Error02 through Error05 are transmitted based on the content level of the tag buffer. They will not be transmitted if uniqueness checking has been disabled to transmit all IDs (“40 Transmit All ID Codes” on page 7-11) or buffer all IDs (“43 Buffer All ID Codes” on page 7-12). For a detailed explanation of buffer control and its associated error messages, refer to “6161 Enable Buffer Control Mode” on page 7-28.

Table 9-1

Error Messages

Error Message

Description

Corrective Action

Error02

Tag buffer is full. Incoming IDs cannot be buffered. An overflow of the tag buffer can occur if SmartPass remains in command mode or if flow control has disabled transmission. A buffer overflow results in subsequent tag IDs being lost.

Put SmartPass in data mode and/or reset flow control to XON. Ensure command 43 (Buffer all IDs) is not enabled.

Error03

Tag buffer has been partially cleared, and new IDs are once again being stored. Error03 will only be issued if Error02 has been issued first.

No action necessary; the previous error has been corrected. However, a significant number of tag IDs still remain in the buffer, so continue to monitor the status for a while to ensure the problem does not return.

Error04

Tag buffer has filled to 75%.

If SmartPass is in command mode, switch to data mode as soon as possible or risk losing some tag IDs. If flow control has disabled transmission (XOFF), reset to XON.

Error05

Tag buffer has emptied to 50%. Error05 will only be issued if Error04 has been issued first.

No action necessary; the previous error has been corrected. However, a significant number of tag IDs still remain in the buffer, so continue to monitor the status for a while to ensure the problem does not return.

9-3

Page 188

AI1620 SmartPass System Guide

Table 9-1 Error Message

9-4

Error Messages (Continued) Description

Corrective Action

Error06

NVRAM parameters have been lost. SmartPass will not function properly because the RF section is shut off until the frequency is reset using command 642.

Reset the frequency using command 642.

Error07

The RF PLL has lost lock and is unable to operate at its intended frequency. RF output is disabled while SmartPass attempts to reset the PLL.

Reset the RF frequency. Refer to

“Radio Frequency” on page 4-27 for instructions.

Error08

The RF PLL has successfully regained lock and has been reset to its proper operating frequency. The RF section is returned to its state prior to losing lock (enabled/disabled). Error08 will only be issued if Error07 has been issued first.

No action necessary; the previous error has been corrected.

Error09

SmartPass software has detected an old or unsupported version of SmartPass hardware and will not function. SmartPass is immediately placed into download mode after issuing this message. This error can only occur on system power-up or reset.

Obtain a copy of the correct version of SmartPass software from Amtech and download it to SmartPass.

Page 189

Troubleshooting and Maintenance

9

Troubleshooting The following table can be used for troubleshooting. Should problems continue after referring to Table 9-2, consult your SmartPass Dealer’s Guide for return and replacement procedures.

Table 9-2 Symptoms and Remedies Symptom Number*

Symptom

Remedy

1

When performing a quick test of SmartPass, the buzz box does not buzz.

Check all your wiring connections, and check that your buzz box is functioning. The wires from SmartPass are grouped in pairs. You could find more than one red wire, more than one black wire, and so on. You must connect the correct red and white wire pair to the leads from the battery. Verify that the red/green wire pair is still twisted together as described in Chapter 4. Twisting the red/green wire pair turns on a continuous RF signal.

2

The baud rate is selected automatically from the DEMO menu on the SmartPass software diskette, but nothing happens.

SmartPass is not communicating with your PC. Check the power supply to your PC, and check the connections between the PC and SmartPass. Try reversing the receive and transmit connections. Verify that the red/green wire pair is still twisted together.

3

When testing SmartPass, all the wires are connected correctly, but the unit does not respond.

SmartPass may not have the software loaded inside the unit. Obtain the SmartPass software diskette from your dealer and using your PC, load the software into the system. If you are using a terminal emulation program, check that the terminal emulation setting on SmartPass is VT100. Check that the SmartPass communication cable is connected to the correct COM port.

4

Strange signal responses come from SmartPass when tested with the PC.

Check the system defaults using the SmartPass software diskette that is supplied to the dealer or distributor. Your system should be set to 9600 baud, 8 bits, 1 stop bit, and no parity.

5

When a tag is moved in front of the reader, a clicking sound comes from SmartPass.

SmartPass works! You hear the relay inside SmartPass that is controlled by a lock signal. The relay is actuated when a tag is in the read zone.

6

Nothing happens when the test tag is passed in front of SmartPass.

Ensure that the red/green pair of wires is twisted together to turn on the RF power continuously. Ensure that SmartPass is powered on and is in predefined output mode.

9-5

Page 190

AI1620 SmartPass System Guide

Table 9-2 Symptoms and Remedies Symptom Number*

Symptom

Remedy

7

SmartPass came from another site and does not work the way the factory defaults indicate that it should.

Different commands were probably used to support the other site’s specific configuration. You can restore the defaults by first disconnecting the power. Next, twist the red/black pair of wires together and power up the SmartPass for 3 or 4 seconds. The factory defaults will be restored.

8

When connected to a PC that is running terminal communications software, a just-powered up SmartPass displays one of the following messages: #Model SP-ACC Ver 2.00D SNYYYYYY #[Copyright notice]

SmartPass works! The software is now loaded. YYYYYY is the Amtech-assigned serial number for this SmartPass. However, if YYYYYY = 000000, the internal battery has failed, or a serial number has never been assigned. If the internal battery has failed, the SmartPass must be returned to the factory for replacement. If a serial number has not been assigned to SmartPass, you can assign a unique serial number by using command 695. Note that each SmartPass unit must have its own unique serial number.

9

The read zone is too small, even before the range control has been adjusted.

If another SmartPass is in the same area, be sure it operates on another frequency that is at least 6 MHz different. Check for possible interference from another nearby RF source: fluorescent lights, neon signs, high voltage power lines, nearby cellular telephone, or radio stations. Lights will need to be removed or shielded. Point SmartPass in a different direction to see if interference comes from only one direction. You may require a different SmartPass that uses another frequency. Verify that the range adjustment is set to the maximum.

10

The perimeter of the read zone has been defined, but there is a “hollow” spot in the center of the zone that does not read tags.

The angle of SmartPass may need adjustment. Slightly tilt SmartPass to a different angle to change either the length or width of the read zone. Check the range control adjustment. See “Radio Frequency” on page 4-27.

11

SmartPass is reading tags out of the desired read zone, or cross-lane reads are occurring.

Some interference from other RF or electrical sources may be occurring. See “Reflection, Refraction, and Diffraction of RF Signals” on page 2-12.

12

How do I download the SmartPass software diskette?

To download SmartPass software, you will need a SmartPass software diskette with READ.ME, DL.EXE, and the software file. Insert the demonstration diskette into your PC, and print the instructions on the READ.ME file.

13

SmartPass is not providing any output to the Wiegand interface.

Ensure SmartPass is in Wiegand mode. The default is either RS-232 or RS-422 mode; refer to “Using Wiegand Interface” on page 4-10.

*

9-6

Use this number to reference the problem you are having with SmartPass if you call Technical Support.