The text of a manual · part 17 of 25
AI1620 SmartPass System Guide, pages 161 to 170
Pages 161 to 170 of 246
The original document is the PDF (4.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec AI1620 and Intermec SmartPass Reader AI1620
Page 161
Installing SmartPass
8
This chapter lists the materials needed and procedures to install and fine-tune SmartPass.
Installation Process After you have developed the site plan, identified the location to install SmartPass, and tested SmartPass, you are ready to install SmartPass. Installation involves the following tasks:
•
Mounting SmartPass on a pole, ceiling, or wall
•
Connecting SmartPass power
•
Setting the read zone
•
Connecting SmartPass host and sense input/sense output communications
Installation Accessory Kits Table 8-1 lists optional Amtech SmartPass installation accessory kits that might be useful: Table 8-1 Installation Accessory Kits Part No.
Description
54-1620-001
Wall or ceiling mount kit
58-1620-001
5-ft connector cable
58-1620-002
20-ft connector cable
20-1620-003
Connector kit only
56-1620-004
13-pair cable (1-ft lengths)
76-1620-005
110 V AC to 18 V AC Class C transformer
76-1620-006
12 V AC to 18 V AC step-up transformer
Cabling Assignments SmartPass power, communications, and customer interface signals are supplied from SmartPass to the host through a multiwire cable (ordered as a separate accessory), which is a 13-pair pigtail. The 13-wire pigtail is a colored wire pair cable, with different colors denoting the individual pairs, only one of which is red/black. In some instances, an alternate 15-pair pigtail may be substituted. The 15-pair pigtail is a red/
8-3
Page 162
AI1620 SmartPass System Guide black wire pair cable, with numbers on the pairs to denote the individual pairs. Two pairs of the 15-pair pigtail, numbers 14 and 15, are not used. SmartPass wiring and cabling assignments for the colored wire pair cable are listed in Table 8-2. Refer to Appendix C for the alternate wiring assignments. Table 8-2 Cabling Assignments for Colored Wire Pair Cable Colored Wire Pair Cable Pair
Red/ Black
Yellow/ Red
Blue/ Red
Orange /Red Brown/ Red
Signal
Description
Typical Function
Pin
Color
A
Black
TX232, RX422+, IF485-
RS-232 transmit, RS-422 receive positive, RS-485 negative
SmartPass output, host input
B
Red
RX232, RX422-, IF485+
RS-232 receive, RS-422 receive negative, RS-485 positive
SmartPass input, host output
C
Yellow
RTS232, TX422+
RS-232 request to send or RS-422 transmit positive
SmartPass output, host input for hardware handshaking
D
Red
CTS232, TX422-
RS-232 clear to send or RS-422 transmit negative
SmartPass input, host output for hardware handshaking
E
Blue
WGND0
Wiegand data0
Parking/access control applications
F
Red
WGND1
Wiegand data1
Parking/access control applications
G
Orange
18V
Main power input
H
Red
18V_RTN
Main power return
J
Brown
18V
Main power input
K
Red
18V_RTN
Main power return
L
White
Lock
Tag lock sense output, activeclosed
Testing maintenance
M
Red
Lock_RTN
Tag lock return
Testing maintenance
White/ Red
8-4
Page 163
Installing SmartPass
8
Table 8-2 Cabling Assignments for Colored Wire Pair Cable Colored Wire Pair Cable Pair
Green/ Red
Blue/ Black
Brown/ Black
Orange /Black
Green/ Black
White/ Black
Signal
Description
Typical Function
Pin
Color
N
Green
Sense Input0
Sense input0 (loop)
Loop and presence detect
P
Red
Sense Input0_RTN
Sense input0 return; not isolated from signal ground
Loop and presence detect
R
Blue
Sense Input1
Sense input1
General-purpose sense input, not used to detect presence.
S
Black
Sense Input1_RTN
Sense input1 return; not isolated from signal ground
General-purpose sense input, not used to detect presence.
T
Black
Out0_COM
Sense output0 (tag detect), common terminal
Switched sense output to control gate
U
Brown
Out0_No
Sense output0 normally open terminal
Switched sense output to control gate
V
Black
Out0_COM
Sense output0 (tag detect output), common terminal
Switched sense output for any external control (light, gate, buzzer, etc.)
W
Orange
Out 0 Normally Closed
Sense output0 normally closed terminal
Switched sense output for any external control (light, gate, buzzer, etc.)
X
Black
Out1_ COM
Sense output1, common terminal
Switched sense output.
Y
Green
Out1_NO
Sense output1 normally open terminal
Switched sense output
Z
Black
Out1_ COM
Sense output1, common
Switched sense output a
White
Out1_NO
Sense output1 normally closed terminal
Switched sense output
8-5
Page 164
AI1620 SmartPass System Guide
Table 8-2 Cabling Assignments for Colored Wire Pair Cable Colored Wire Pair Cable Pair
Yellow/ Black
Signal
Description
Typical Function
Pin
Color b
Yellow
GND logic ground
Signal ground (used with RS232 and Wiegand communications)
c
Black
GND logic ground
Signal ground (used with RS232 and Wiegand communications)
Mounting SmartPass to Round Pole or Flat Surface This section lists materials required and procedures for mounting SmartPass on a round pole or on a ceiling, wall, or other flat surface, based on the site’s requirements.
Mounting SmartPass on a Round Pole SmartPass can be simply and inexpensively mounted on virtually any pole regardless of its diameter. Follow the instructions below for mounting SmartPass to a pole.
Materials Required You will need the following materials to install SmartPass:
8-6
•
A 5/32-in. Allen wrench to assemble and adjust the mounting brackets
•
Two 1/2-in. (1.3 cm) stainless steel hose clamp straps, 12-in. (30.5 cm) length for a typical 2-in. (5 cm) diameter pole
•
Two 1/2-in. (1.3 cm) stainless steel hose clamp straps, 24-in. (61 cm) length for a 10-in. (25 cm) diameter pole
•
Flat-tip screwdriver or adjustable wrench to tighten hose clamp straps
Page 165
Installing SmartPass
8
Procedures Use the following procedures to mount SmartPass to a pole. 1. Unpack SmartPass. A factory-mounted bracket (Figure 8-1) is attached to the back of SmartPass, and a pole mount bracket assembly (Figure 8-2) is bubblewrapped with SmartPass and contains a plastic bag of screws.
Figure 8-1 Factory-Mounted Bracket
Figure 8-2 Pole Mount Bracket Assembly
2.
Using the two 1/2-in. (1.3 cm) stainless steel straps, attach the pole mount bracket assembly to the pole approximately 6 to 8 ft (1.8 to 2.4 m) above the pavement surface. Tighten slightly so you can adjust SmartPass left or right, but not so slightly that it will slide down the pole.
8-7
Page 166
AI1620 SmartPass System Guide
3.
Using the four machine screws and washers, attach SmartPass to the pole mount bracket (Figure 8-3). Tighten the screws slightly so that SmartPass can be adjusted up or down.
Figure 8-3 SmartPass Mounted Using Pole Mount Bracket
4.
8-8
Adjust the assembly by pointing SmartPass to the middle of the area where tags will be read and tighten all screws and straps. Figure 8-4 illustrates a front and top view of a pole-mounted SmartPass. The figure shows the approximate measurements used for sites where tags would be mounted on the interior driver’s side windshield
Page 167
Installing SmartPass
8
.
Note: These are approximate dimensions for sites where tags will be mounted on the driver’s side. Adjust SmartPass to match site and tag mounting positions to provide the most direct line of sight to the tags. Figure 8-4 Front and Top Views of SmartPass Position
Mounting SmartPass to a Wall or Ceiling Because SmartPass weighs only 9 1/2 lbs (4.3 kg), 1/4-in. (0.6 cm) bolt hardware is adequate to secure the unit to a wall or ceiling.
Materials Required You will need the following materials to install SmartPass on a wall or ceiling. Be sure to use high-quality corrosion-resistant anchor hardware.
•
Anchor hardware suitable for the surface on which you will mount SmartPass
•
Four hex nuts 3/8-16 threaded and four lockwashers 3/8-in. threaded
8-9
Page 168
AI1620 SmartPass System Guide
•
5/32-in. Allen wrench
•
SmartPass wall mount bracket accessory kit (recommended)
The basic SmartPass is supplied with a pole mount bracket assembly (Figure 8-2) that allows you to adjust SmartPass up and down. Amtech recommends using the wall mount bracket accessory kit (Figure 8-5) to provide additional horizontal aiming flexibility when attaching SmartPass to a pole with flat sides, or to a wall or ceiling where other structures may interfere with accurately aiming SmartPass toward the tags.
Figure 8-5 Wall Mount Bracket Accessory
Procedures Use the following instructions to mount SmartPass to a wall or ceiling using the pole mount and wall mount bracket accessory kits. 1. Unpack SmartPass. Set aside the pole mount bracket. This bracket will be used in the steps below to provide greater adjustment for SmartPass. The pole mount bracket is wrapped separately from SmartPass and contains a plastic bag of screws.
8-10
2.
Using the 5/32-in. Allen wrench, remove the factory-mounted bracket attached to the back of SmartPass. Remove all four machine screws and washers from the bracket.
3.
Unpack the optional wall mount bracket accessory kit.
Page 169
Installing SmartPass
4.
8
Using the screws and washers set aside in Step 2, attach the wall mount bracket to the back of SmartPass, as shown in Figure 8-6.
Figure 8-6 Wall Mount Bracket Attached to SmartPass
5.
Tighten the screws to secure this bracket.
6.
Using the four machine screws and washers, attach the factory mount bracket to the wall mount bracket, lining up the four outside screw holes (Figure 8-7).
Figure 8-7 Factory Mount Bracket Attached to Wall Mount Bracket
7.
Tighten lightly, since you will want to adjust later. This subassembly allows SmartPass to be aimed left or right when all three brackets are assembled.
8-11
Page 170
AI1620 SmartPass System Guide
8.
Mount the pole mount bracket to the wall, ceiling, or fixture using appropriate anchors (Figure 8-8).
Figure 8-8 Pole Mount Bracket Attached to Wall
9.
Mount SmartPass to the pole mount bracket using machine screws, as shown in Figure 8-9.
Figure 8-9 Connecting SmartPass Assembly to Pole Mount Bracket
10. Adjust and tighten machine screws in both axes to point SmartPass at the read zone.
8-12