Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 9 of 14

9710 and 9720 Wedge Readers User's Manual, pages 81 to 90

Pages 81 to 90 of 138

The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 9710

Page 81

Configuring the Reader

3

If you map more than 12 keystrokes on the 9710 reader or 36 keystrokes on the 9720 reader, the additional keystrokes are not stored in EEPROM and will be lost after a power cycle. After you enter the maximum number of keystrokes, the reader emits a high/low beep sequence after each additional alteration to indicate that these are temporary alterations. If you redefine the workstation configuration, the look-up table modifications are deleted. Note: With some workstations, keypad and/or function keys cannot be remapped. When multiple keys are assigned to one ASCII character: • You have ten seconds to press the first key, but only one second to press each following key. • The Shift key does not count as a keystroke if it is held down while hitting another key. The shift key only counts as a keystroke if it is pressed and released before pressing another key. • When multiple keystrokes are mapped to an ASCII character, scanning that ASCII bar code sends the remapped keystrokes as if the keys were all held down at the same time. For example, if you remap the keystroke sequence Ctrl Alt Delete by pressing and releasing each key individually, when the assigned ASCII character is scanned, the sequence is sent to the workstation as if all three keys were pressed at once: Ctrl-Alt-Delete. If you are using a Wyse terminal, note the following differences: • Only one key is allowed to be pressed at a time. • The shift key does not count as a keystroke when followed by another key. For example, pressing and releasing Shift then A would be considered one keystroke (A). Note: With some workstations, the number of keystrokes that can be remapped to an ASCII character are reduced when mixing uppercase and lowercase. If a replacement keystroke is already associated with another ASCII character, that keystroke is active in both places.

3-47

Page 82

9710 and 9720 Wedge Readers User’s Manual

To alter one or more ASCII to keystroke equivalents 1. Scan this bar code. Modify Look-Up Table

*$+WM* *$+WM*

2. Scan the ASCII character on the full ASCII chart that you wish to redefine. 3. Press the keystroke combination you are mapping to the bar code. You must enter the bar code character and keystroke combination within 10 seconds after you scan the Modify Look-Up Table bar code. To return to normal keystroke settings

• Scan your workstation configuration bar code in the WIF guide. Example: Modifying Your Keyboard

This example configures the reader to transmit a space whenever you scan an S. 1. Scan this bar code to modify the keyboard keystrokes. Modify Look-Up Table

*$+WM* *$+WM*

2. Scan the letter S bar code on the full ASCII chart at the end of this manual. 3. Press the spacebar on your keyboard to remap the S to a space. The reader modifies the keyboard configuration and emits one high beep indicating that the modification was successful.

3-48

Page 83

Configuring the Reader

3

4. Scan this bar code.

* * * *

The workstation monitor displays a space. 5. Scan this bar code.

*S* *S*

The workstation monitor displays a space.

3-49

Page 84

This page is a scan with no text; see it in the PDF.

Page 85

4 Configuring the 9720 Serial Port

Page 86

This page is a scan with no text; see it in the PDF.

Page 87

Configuring the 9720 Serial Port

4

This chapter applies only to the 9720 Wedge Reader and describes how to install and configure the wedge reader for use with a scale or portable reader.

Connecting to the Serial Port The 9720 serial port can be used to receive data from a portable reader or a counting or weighing scale. Data can also be transmitted out the serial port. The serial port is designed to receive data using an RS-232 interface and Point-to-Point protocol. The table below lists the default serial port configuration parameters. Parameter

Setting

Baud Rate

9600

Parity

Even

Data Bits

7

Stop Bits

1

Intercharacter Delay (serial port)

0 msec

Timeout Delay

2 sec

Echo

Disabled

Flow Control

XON/XOFF control

TXEOM

Carriage return line feed

RXEOM

Carriage return line feed

Solicitation Message

No message

Before connecting a portable reader or scale to the 9720 wedge reader, it is necessary to connect the wedge reader to the workstation and configure the wedge reader operating parameters. Wedge reader installation is described in Chapter 1. The serial port connector is located on the wedge reader rear panel. The following figure shows the pin assignments for the 25-pin connector.

4-3

Page 88

9710 and 9720 Wedge Readers User’s Manual

Wedge Reader Serial Port Connector Pin Assignments powe r audio input term inal keyb oard

12

3

J1 Chassis GND TX RX +5v RTS CTS NC Signal GND DSR

1 2 3 4 5 20 7 6

(Incoming) (Outgoing) (Incoming) (Outgoing) (Required)

9720 Serial Port (DCE)

Connecting a Portable Reader The following Intermec portable readers can be connected to the 9720 Wedge Reader: • 9440 TRAKKER Portable Reader • 9444 TRAKKER Scanner • 9445 TRAKKER Scanner • 9460 TRAKKER Portable Reader • 9462 TRAKKER Portable Reader Connect the portable reader to the wedge reader at the serial port connector located on the wedge reader rear panel. RS-232 cable connector pin assignments are shown in the following figure.

4-4

Page 89

Configuring the 9720 Serial Port

4

944X and 946X Portable Reader Cable Connectors (P/N 048864)

J1

J2

1 2 3 4 5 20 7 6

1 2 3 4 5 6 7 8 9 10

9720 Serial Port (DCE)

944X 946X (DTE)

Chassis GND TX RX +5v RTS CTS NC Signal GND DSR

CHASSIS GND TX RX RTS CTS DTR NC IOSENS DOCK PWR SUPPLY Signal GND

Connecting a Scale You can connect a counting or weighing scale to the 9720 Wedge Reader at the RS-232 serial port and transfer scale data through the reader to the workstation. Operating with a scale does not change your workstation operation or the operation of the accessories you have connected to the wedge reader. Connect the scale to the wedge reader at the serial port connector located on the wedge reader rear panel. Refer to the figure of the pin assignments for the wedge reader serial port and the installation and operation manuals for your scale for specific information about the type of connector you need to operate your scale with an RS-232 interface. Note: The serial port connector on the 9720 is configured as DCE.

4-5

Page 90

9710 and 9720 Wedge Readers User’s Manual

Uploading Data When possible, the portable reader or scale should be configured for the default settings of the wedge reader serial port. By carefully configuring and monitoring the portable reader/scale and configuring the wedge reader, you can successfully control the transmission of serial port data through the wedge reader to the workstation. Some applications may require operator interaction to prevent data loss due to slow or unpredictable host or application responses. Characters received by the wedge reader are held in a buffer until an end of record occurs. End of record is defined by one of the following conditions: • 256 characters are received. • Characters are not received within the configured timeout period. • An end of message (EOM) is received. Each data record from a scale/portable reader must have an EOM. Typically the EOM is a Carriage Return (<CR>) or a Line Feed (<LF>). The wedge reader searches the transmission for the EOM as a check for a complete transmission. When the wedge reader receives the EOM, the data record is sent to the workstation. See your scale/portable reader user’s manual or inspect a scale/portable reader transmission to identify the EOM. The wedge reader strips defined characters and appends any configured preambles and postambles to the scale/portable reader transmission before sending it to the workstation. If an error occurs when receiving data through the serial port (for instance, a configured timeout occurs before an EOM is received), the wedge reader beeps and continues operation.

Uploading Data From a Portable Reader There are three common ways to start data transmission for the portable reader: • Press a key combination on the portable reader. Refer to your portable reader user’s manual for instructions on transmitting data. 4-6