Page 91
Configuring the 9720 Serial Port
4
• The portable reader receives a command to transmit from the wedge reader. Refer to page 4-14 for information about defining the solicitation message. • Transmit from an IRL program. For more information on programming the portable reader and preparing for data collection, see “Other Intermec Manuals” in the front of this book. Note: Do not scan information or enter data from the keyboard when you are transmitting data from the portable reader. To do so interferes with the transmission and data may be altered. Configure the portable reader for the Point-to-Point protocol settings listed below. Parameter
Setting
Parameter
Setting
CTS Checking
No
XON
DC1
Baud Rate
9600
XOFF
DC3
Parity
Even
Timeout Delay
10 sec
Data Bits
7
Intercharacter Delay
0 ms
Stop Bits
1
Turnaround Delay
0 ms
Uploading Data From a Scale There are three common ways to command the scale to send data through the RS-232 line: • The operator presses a key (PRINT) on the scale. • A switch, external to the scale but wired to it, is closed. • The scale receives a command through the RS-232 serial line from the wedge reader. The first two transmission commands are initiated by the operator. For the third command, the wedge reader solicits the scale requesting transmission of data. You must define the solicitation message and transmit the message to the scale by scanning a command bar code.
4-7
Page 92
9710 and 9720 Wedge Readers User’s Manual
Serial Port Configuration Parameters The following tables define various configuration parameters for the wedge reader’s serial port. The dagger (†) indicates the factory default setting.
Baud Rate This parameter defines the rate at which data is transmitted/received by the serial port. 110
2400
*$+IA0*
*$+IA4*
*$+IA0*
*$+IA4*
300
4800
*$+IA1*
*$+IA5*
*$+IA1*
*$+IA5*
600
9600
*$+IA2*
*$+IA6*
*$+IA2*
*$+IA6*
1200
19200
*$+IA3*
*$+IA7*
*$+IA3*
*$+IA7*
†
Parity This parameter defines the number of 1s in a data block. Parity is used for error checking in data transmission. The number of 1s in a data block are counted and a 0 or 1 (parity bit) is added so the data block has the correct parity before transmission.
4-8
Page 93
Configuring the 9720 Serial Port
Disabled
Mark
*$+IB0*
*$+IB3*
*$+IB0*
*$+IB3*
Even
†
4
Space
*$+IB1*
*$+IB4*
*$+IB1*
*$+IB4*
Odd
*$+IB2* *$+IB2*
Data Bits This parameter defines the number of bits in the data record received by the serial port. 7
†
8
*$+II7*
*$+II8*
*$+II7*
*$+II8*
Stop Bits This parameter defines the number of additional characters sent with the data transmission to indicate the end of data. 1
†
2
*$+IC1*
*$+IC2*
*$+IC1*
*$+IC2*
4-9
Page 94
9710 and 9720 Wedge Readers User’s Manual
Timeout Delay This parameter defines how long the wedge reader waits between characters when receiving data. The timeout is enabled with the receipt of the first character in the message. If data stops arriving before an EOM character is received, the wedge reader waits the specified timeout period. When the timeout period expires, the data is transmitted to the workstation and the buffer count (the count of the incoming message) resets to zero. 0 sec
10 sec
*$+IE8*
*$+IE4*
*$+IE8*
*$+IE4*
5 msec
20 sec
*$+IE0*
*$+IE5*
*$+IE0*
*$+IE5*
100 msec
40 sec
*$+IE1*
*$+IE6*
*$+IE1*
*$+IE6*
500 msec
60 sec
*$+IE2*
*$+IE7*
*$+IE2*
*$+IE7*
2 sec
†
*$+IE3* *$+IE3*
4-10
Page 95
Configuring the 9720 Serial Port
4
Echo This parameter echoes any data sent to the serial port back to the device that is transmitting data (normally not used). Disabled
†
Enabled
*$+IM0*
*$+IM1*
*$+IM0*
*$+IM1*
Flow Control This parameter controls the data transmission for the serial port. The wedge reader is a DCE device. Clear to Send/Request to Send (CTS/RTS) is a hardware signal flow control. The reader checks RTS before transmission of each character. The reader uses CTS to control incoming data flow. XON/XOFF response specifies that the wedge reader responds to XON/XOFF characters received while transmitting. XON/XOFF control specifies that XON/XOFF characters are transmitted by the wedge reader to control data flow. XON/XOFF response and control specifies the wedge reader responds to and transmits XON/XOFF characters. †
None
XON/XOFF Control
*$+IL0*
*$+IL3*
*$+IL0*
*$+IL3*
CTS/RTS Checking and Control
XON/XOFF Response and Control
*$+IL1*
*$+IL4*
*$+IL1*
*$+IL4*
XON/XOFF Response
*$+IL2* *$+IL2*
4-11
Page 96
9710 and 9720 Wedge Readers User’s Manual
RXEOM This parameter defines the receive end of message (RXEOM) for the serial port. An EOM is sent by the portable reader/scale to indicate the end of a data record. The wedge reader strips the EOM before transmitting data to the workstation. Carriage Return Line Feed (<CR><LF>) is the default configuration. Note: If you are using quotes (") in your data string, refer to the note on page 3-15. Disabled
*$+PJ* *$+PJ*
To define the RXEOM
1. Scan this bar code. Accumulate/Change Config/RXEOM
*+/$+PJ* *+/$+PJ*
2. Scan this bar code. Beginning of Data
*/B* *"*
3. Scan 1 to 2 characters on the full ASCII chart to build the RXEOM. 4. Scan this bar code. End of Data
*/B* *"*
4-12
Page 97
Configuring the 9720 Serial Port
4
5. Scan this bar code. Exit Accumulate
*-/* *-/*
TXEOM This parameter defines the transmit end of message (TXEOM) for the serial port. The serial port sends an EOM to indicate the end of a data record when transmitting data from the reader. Carriage Return Line Feed (<CR><LF>) is the default setting. Note: If you are using quotes (") in your data string, refer to the note on page 3-15. Disabled
*$+PI* *$+PI*
To define TXEOM
1. Scan this bar code. Accumulate/Change Config/TXEOM
*+/$+PI* *+/$+PI*
2. Scan this bar code. Beginning of Data
*/B* *"*
3. Scan 1 to 2 characters on the full ASCII chart to build the TXEOM.
4-13
Page 98
9710 and 9720 Wedge Readers User’s Manual
4. Scan this bar code. End of Data
*/B* *"*
5. Scan this bar code. Exit Accumulate
*-/* *-/*
Solicitation Message This parameter defines the solicitation message for the serial port. The message can be sent from the wedge reader to the portable reader or scale at any time by scanning the transmit message command. The solicitation message commands the portable reader/scale to transmit data through the RS-232 interface to the wedge reader. Your scale service manual or portable reader user’s manual contains a list of such commands with the ASCII character equivalents. Solicitation messages are stored in EEPROM and remain defined until you change them. Note: If you are using quotes (") in your data string, refer to the note on page 3-15. Solicitation Message Cleared
*$+WS* *$+WS*
4-14
†
Page 99
Configuring the 9720 Serial Port
4
To define the solicitation message
1. Scan this bar code. Accumulate/Change Config/Solicitation Message
*+/$+WS* *+/$+WS*
2. Scan this bar code. Beginning of Data
*/B* *"*
3. Scan 1 to 15 characters using the bar codes on the full ASCII chart to build the solicitation message. 4. Scan this bar code. End of Data
*/B* *"*
5. Scan this bar code. Exit Accumulate
*-/* *-/*
4-15
Page 100
9710 and 9720 Wedge Readers User’s Manual
Example: Defining a Solicitation Message
The following example describes how to define a solicitation message for the portable reader. 1. Scan this bar code to configue a solicitation message. Accumulate/Change Config/Solicitation Message
*+/$+WS* *+/$+WS*
2. Scan this bar code to define the solicitation message. Beginning of Data
*/B* *"*
3. Scan the following bar codes on the full ASCII chart at the end of this manual: % % A <CR> <LF>. <CR> is the CR bar code and <LF> is the LF bar code on the full ASCII chart. The % % characters tell the reader to transmit data. The A character specifies the file name. <CR><LF> are the EOM characters. 4. Scan this bar code to end the configuration of the solicitation message. End of Data
*/B* *"*
5. Scan this bar code to exit the accumulate feature and modify the configuration. Exit Accumulate
*-/* *-/*
When the solicitation message is transmitted to the portable reader, the portable reader begins transmitting File A.
4-16