For the Intermec 9710

Page 101

5 Data Edit Application

Page 102

This page is a scan with no text; see it in the PDF.

Page 103

Data Edit Application

5

This chapter provides information on using the Data Edit application for stripping specific characters from a data record.

Running Data Edit Note: The information in this chapter does not apply to the 9710X01 Wedge Reader. To verify the type of reader you are using, look at the label on the base of the reader for a number similar to 9710X02. This number specifies the following information: (1) the reader type (9710 or 9720), (2) the revision letter (E, F, G, etc.), and (3) the version number (01 or 02). With Data Edit running, the reader can: • Search the incoming data record for the pre-defined data. • Strip control characters, status words, or checksums from the data record. • Strip characters from the beginning and/or end of a data record.

Using Data Edit Configuration Parameters You can configure the reader to manipulate data from a scanner, the serial port, or both at the same time. The Window and Data Source parameters define the source of the data and Data Identifier, Data Begin, and Data End define how to modify the data. You can run Data Edit upon power-on, in place of Standard Operation mode, or you can run Data Edit by scanning the Run Program command.

Application Program This parameter determines the application that is run on power-up: Standard Operation or Data Edit. If you configure the reader for Data Edit, the reader resets before running Data Edit. To return to Standard Operation, scan the Standard Operation bar code.

Standard Operation†

Data Edit

*$+GA0*

*$+GA1*

*$+GA0*

*$+GA1* 5-3

Page 104

9710 and 9720 Wedge Readers User’s Manual

If you want to run Data Edit temporarily, scan the Run Program command.

Run Program

*//* *//*

Note: You need to configure the reader before scanning the Run Program command. Any type of reset (for example, scanning the reset command or configuring a parameter) exits Data Edit and returns the reader to Standard Operation. The following parameters define the data source (scanner or serial port) and the characters to strip from data records that the reader receives. You can configure these parameters running Standard Operation or Data Edit, but the parameters only function when the Data Edit application is running.

Window This parameter defines the source of the data records. Use Window to strip a specified number of characters from the beginning and end of a data record. Window is run before the Data Identifier parameter.

Window Disabled

Window Serial Port Data †

*$+WH0*

*$+WH2*

*$+WH0*

*$+WH2*

Window Scanner Data

Window Scanner and Serial Port Data

*$+WH1*

*$+WH3*

*$+WH1*

*$+WH3*

5-4

Page 105

Data Edit Application

5

Data Begin and Data End These parameters strip characters from data records the reader receives. For example, these parameters are useful when you use the Window parameter for a scale connected to the reader serial port. Scales send several types of information, such as count, weight, and data that typically goes to a printer. As a result, the data records contain non-printing control characters as well as data. Configure Data Begin and Data End to strip these non-printing control characters from the data record before sending the data to the workstation.

Data Begin This parameter defines the number of characters that are stripped from the beginning of a data record. The characters are stripped before the addition of preambles and the information is sent to the workstation. This parameter is typically used with scales.

No Stripping†

*$+WB0* *$+WB0*

To strip characters from the beginning of the data record 1. Scan this bar code. Accumulate/Change Config/Data Begin

*+/$+WB* *+/$+WB*

2. Scan a number between 1 and 99.

*1* *2* *3* *4* *5* *1*

*2*

*3*

*4*

*5*

*6* *7* *8* *9* *0* *6*

*7*

*8*

*9*

*0*

5-5

Page 106

9710 and 9720 Wedge Readers User’s Manual

3. Scan this bar code. Exit Accumulate

*-/* *-/*

Data End This parameter defines the number of characters that are stripped from the end of a data record. The characters are stripped before the addition of postambles and the information is sent to the workstation. No Stripping

†

*$+WE0* *$+WE0*

To strip characters from the end of the data record

1. Scan this bar code. Accumulate/Change Config/Data End

*+/$+WE* *+/$+WE*

2. Scan the number of characters, betwen 1 and 99, you want to strip.

*1* *2* *3* *4* *5* *1*

*2*

*3*

*4*

*5*

*6* *7* *8* *9* *0* *6*

*7*

3. Scan this bar code. Exit Accumulate

*-/* *-/*

5-6

*8*

*9*

*0*

Page 107

Data Edit Application

5

Data Source This parameter defines the source of the data records. Data Source is used with Data Identifier which searches for a set pattern in the data record and passes the data record or strips the pattern before passing the data record. Note: Window takes precedence over Data Source. Data Source Disabled

Data Source Serial Port Data

*$+DH0*

*$+DH2*

*$+DH0*

*$+DH2*

Data Source Scanner Data

†

Data Source Scanner and Serial Port Data

*$+DH1*

*$+DH3*

*$+DH1*

*$+DH3*

Data Identifier This parameter defines the pattern that the reader searches for in a data record and how to process the data. The pattern can be a space, an alpha character, or a user-defined pattern. The reader can strip the pattern, pass the data record unmodified, or reject the data record if the pattern is not found. Disable

†

*$+DI0* *$+DI0*

5-7

Page 108

9710 and 9720 Wedge Readers User’s Manual

To define the data identifier

1. Scan this bar code. Accumulate/Change Config/Data Identifier

*+/$+DI* *+/$+DI*

2. Scan one of the bar codes below to define the data identifier pattern. Pattern 1 A space in positions 2 through 5 of a data record defines a pattern of all characters up to and including the first space.

*1* *1*

For example, there are two data records: 12 345 and A 3 45. The pattern for the first data record is 1, 2 and the space. The pattern for the second data record is A and the space. Pattern 2 An alpha character in position 1 through 4 of a data record defines a pattern of all characters up to and including the first alpha character. (A space immediately following the alpha character is included.)

*2* *2*

For example, there are two data records: 12ABC and A 3B45. The pattern for the first data record is 1, 2 and A. The pattern for the second data record is A and the space. Pattern 3 This pattern is user-defined and stored in reader memory. Refer to the next section, “User-Defined Pattern,” for information on creating and using a user-defined pattern.

*3* *3*

5-8

Page 109

Data Edit Application

5

3. Scan one of the bar codes below to define data handling: • Pattern present - strip pattern and transmit data. Pattern not present - reject data record.

*0* *0*

• Pattern present - transmit data record unmodified. Pattern not present - reject data record.

*1* *1*

• Pattern present - strip pattern and transmit data. Pattern not present - transmit data record unmodified.

*2* *2*

4. Scan this bar code. Exit Accumulate

*-/* *-/*

User-Defined Pattern

This parameter defines a pattern to find in the data record. Reader memory has space for up to 32 patterns, with a maximum of 5 characters in each pattern. The characters can be numeric, uppercase alpha, or wild card characters @, #, and ?. Wild card characters represent a character type: @ is any uppercase alpha character. # is any numeric character. ? is any character.

5-9

Page 110

9710 and 9720 Wedge Readers User’s Manual

To delete the user-defined patterns from memory, you must scan the Default Configuration command listed in Chapter 2. Note: If you are using quotes (") in your data string, refer to the note on page 3-15. To define a pattern

1. Scan this bar code. Accumulate/Change Config/User-defined Pattern

*+/$+DI4* *+/$+DI4*

2. Scan this bar code. Beginning of Data

*/B* *"*

3. Scan 1 to 5 characters from the full ASCII chart. The characters can be numeric, uppercase alpha, @, #, or ?. 4. Scan this bar code. End of Data

*/B* *"*

5. Scan this bar code. Exit Accumulate

*-/* *-/*

5-10