Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 8 of 14

9710 and 9720 Wedge Readers User's Manual, pages 71 to 80

Pages 71 to 80 of 138

The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 9710

Page 71

Configuring the Reader

3

3. Scan this bar code. Exit Accumulate

*-/* *-/*

2 of 5 Code 2 of 5 Code uses the bars to encode information and the spaces to separate the individual bars. This code is discrete and self-checking. Decoding for 2 of 5 code can only be enabled if decoding for the I 2 of 5 code is disabled. If I 2 of 5 is enabled, 2 of 5 code is automatically disabled. 2 of 5 code has two parameters. Disable

†

*$+CC00* *$+CC00*

To define 2 of 5 code

1. Scan this bar code. Accumulate/Change Config/2 of 5 Code

*+/$+CC* *+/$+CC*

2. Scan one of the bar code parameters. Three Bar Start/Stop

†

Two Bar Start/Stop

*0*

*1*

*0*

*1*

3. Scan a two digit number from 01 to 32 to specify the label length.

*1* *2* *3* *4* *5* *1*

*2*

*3*

*4*

*5*

*6* *7* *8* *9* *0* *6*

*7*

*8*

*9*

*0* 3-37

Page 72

9710 and 9720 Wedge Readers User’s Manual

4. Scan this bar code. Exit Accumulate

*-/* *-/* Example: Defining 2 of 5 Code

This example configures the reader to decode 2 of 5 Code encoding twelve digits with a two bar start/stop code. 1. Scan this bar code to configure 2 of 5 Code. Accumulate/Change Config/2 of 5 Code

*+/$+CC* *+/$+CC*

2. Scan the Two Bar Start/Stop bar code to decoded bar codes that have a two bar combination that designate the start and stop of the bar code. Two Bar Start/Stop

*1* *1*

3. Scan bar codes 1 and 2 to decode bar codes that encode tweleve digits.

*1* *2* *1*

*2*

4. Scan this bar code to exit the accumulate feature and modify the configuration. Exit Accumulate

*-/* *-/*

3-38

Page 73

Configuring the Reader

3

Plessey Code Plessey Code is pulse width modulated. The code includes a start character, data characters, an eight-bit cyclic check digit, a termination bar and usually a reverse start character. The code is continuous and not self-checking. Plessey code has two parameters. Parameter 1 Disable

†

Parameter 2 Retain Check Digit

*$+CI00*

*$+CI30*

*$+CI00*

*$+CI30*

Plessey With Reverse Start Code

Discard Check Digit

*$+CI10*

*$+CI31*

*$+CI10*

*$+CI31*

MSI Code MSI Code uses the same principle as Plessey code. The MSI code includes a start pattern, data characters, one or two check digits, and a stop pattern. MSI code requires two parameters.

To define MSI Code 1. Scan this bar code. Accumulate/Change Config/MSI Code

*+/$+CN* *+/$+CN*

2. Scan one of the bar codes parameters. Disable

†

Without Check Digit

*0*

*1*

*0*

*1*

One Modulus 10 Check Digit

Two Modulus 10 Check Digits

*2*

*3*

*2*

*3* 3-39

Page 74

9710 and 9720 Wedge Readers User’s Manual

3. Scan one of the bar code parameters. Discard Check Digit

Retain Check Digit

*0*

*1*

*0*

*1*

4. Scan this bar code. Exit Accumulate

*-/* *-/* Example: Defining MSI Code

This example configures the reader to decode MSI Code with two modulus 10 check digits that the reader discards before transmitting the data to the workstation. 1. Scan this bar code to configure MSI Code. Accumulate/Change Config/MSI Code

*+/$+CN* *+/$+CN*

2. Scan this bar code to decode bar codes that have two modulus 10 check digits. Two Modulus 10 Check Digits

*3* *3*

3. Scan this bar code to discard the two modulus 10 check digits before transmitting the data to the workstation. Discard Check Digit

*0* *0*

3-40

Page 75

Configuring the Reader

3

4. Scan this bar code to modify the configuration. Exit Accumulate

*-/* *-/*

Universal Product (UPC)/European Article Numbering (EAN) Codes

Universal Product (UPC)/European Article Numbering (EAN) Codes are fixed length, numeric, continuous symbologies that use four element widths. An EAN configured reader can decode UPC, but the reverse is not true. UPC code is a subset of EAN code. The UPC/EAN codes have seven parameters. To define UPC/EAN Code

1. Scan this bar code. Accumulate/Change Config/UPC/EAN Code

*+/$+CE* *+/$+CE*

2. Scan one of the bar code parameters. Disable UPC A/EAN 13

Enable UPC A/EAN 13

Enable UPC A Only

*0*

*1*

*2*

*0*

*1*

*2*

3. Scan one of the bar code parameters. Disable UPC E

Enable UPC E

*0*

*1*

*0*

*1*

†

4. Scan one of the bar code parameters. Disable EAN 8

Enable EAN 8

*0*

*1*

*0*

*1*

†

3-41

Page 76

9710 and 9720 Wedge Readers User’s Manual

5. Scan one of the bar code parameters. †

No Supplemental Allowed

Supplementals Allowed

Supplemental Required

*0*

*1*

*2*

*0*

*1*

*2*

6. Scan one of the bar code parameters. Discard Check Digit

Retain Check Digit

*0*

*1*

*0*

*1*

†

7. Scan one of the bar code parameters. Discard Number System

Retain Number System

*0*

*1*

*0*

*1*

†

8. Scan one of the bar code parameters. Do Not Insert UPC A Leading Zero

Insert UPC A Leading Zero

*0*

*1*

*0*

*1*

9. Scan this bar code. Exit Accumulate

*-/* *-/*

3-42

†

Page 77

Configuring the Reader

3

Example: Defining UPC/EAN

This example configures the reader to decode UPC A/EAN 13, with supplementals, inserts a leading zero in front of the UPC A bar code, and disables the reader from decoding UPC E/EAN 8. 1. Scan this bar code to configure UPC/EAN. Accumulate/Change Config/UPC/EAN Code

*+/$+CE* *+/$+CE*

2. Scan this bar code to decode UPC A. UPC A encodes twelve digits and EAN 13 encodes thirteen digits. Enable UPC A/EAN 13

*1* *1*

3. Scan this bar code to disable the reader from decoding UPC E which encodes six digits. Disable UPC E

*0* *0*

4. Scan this bar code to disable the reader from decoding EAN 8 which encodes eight digits. Disable EAN 8

*0* *0*

5. Scan this bar code to decode supplementals which encode two or five digits. One use of this code is to designate the month or week of publication for magazines. Supplementals Allowed

†

*1* *1*

3-43

Page 78

9710 and 9720 Wedge Readers User’s Manual

6. Scan this bar code to discard the check digit before transmitting the data to the workstation. Discard Check Digit

*0* *0*

7. Scan this bar code to discard the number system or flag digit(s) before transmitting the data to the workstation. Discard Number System

*0* *0*

One digit is discarded from the beginning of a UPC A, UPC E, or EAN 8 bar code. Two digits are discarded from the beginning of an EAN 13 bar code. If more than two digits need to be discarded, use the Window command. For more information, see Chapter 5. 8. Scan this bar code to place a leading zero in front of the bar code, if necessary. (This parameter is only necessary when both UPC A and EAN 13 are enabled.) Insert UPC A Leading Zero

†

*1* *1*

9. Scan this bar code to exit the accumulate feature and modify the configuration. Exit Accumulate

*-/* *-/*

3-44

Page 79

Configuring the Reader

3

Customizing ASCII to Keyboard Equivalents The reader ships with internal software that includes definitions of the keystrokes that are invoked when you scan ASCII characters. Common keyboard keystrokes are listed in the keyboard equivalency tables in the Appendix. The following instructions describe how to display the default ASCII keycode equivalent for any key pressed on the keyboard. The ASCII keycode equivalent is displayed in decimal form. If the key is not supported in the reader, the workstation displays -128.

To display default ASCII keycode equivalents 1. Scan these bar codes.

*..-.*

*41*

*..-.*

*41*

2. Press the key on the workstation keyboard that you want to display. The workstation monitor displays the ASCII equivalent in decimal form. 3. Check the ASCII character table in the Appendix for the binary or hexadecimal equivalent for the character. 4. Repeat steps 2 and 3 for the keys you want. 5. Scan these bar codes to exit the keycode display.

*S*

*99*

*S*

*99*

6. The reader beeps within 10 seconds. If the reader does not beep, turn the workstation off and then on again.

3-45

Page 80

9710 and 9720 Wedge Readers User’s Manual

Example: Determining Keycode Equivalents

The following example shows how to find the ASCII keycode equivalent for a and A. 1. Scan this bar code to enable the keycode display routine.

*..-.*

*41*

*..-.*

*41*

2. Press A on your workstation keyboard to display 97 on the screen. 3. Look up 97 in the ASCII character table in the Appendix. The decimal value 97 has an ASCII character value of “a”. 4. Press Shift-A. The workstation displays 65 on the screen. 5. Look up 65 in the ASCII character table in the Appendix. The decimal value 65 has an ASCII character value of “A”. 6. Scan this bar codes to exit the keycode display routine.

*S*

*99*

*S*

*99*

If the reader does not beep within 2 to 10 seconds after scanning the bar codes, cycle power to the workstation. The a key character is standard for most keyboards. However, there may be some key characters that do not have a readily evident ASCII character equivalent (for example, a function key or a control key). The ASCII-to-keystroke translation settings can be customized for a specific workstation by changing the default keystrokes of the reader to other keyboard characters. Up to four keystrokes can be mapped to an ASCII character. The 9710 reader can store twelve keystrokes in EEPROM and the 9720 reader can store 36 keystrokes in EEPROM. The reader sounds one high beep followed by four low beeps after it stores the keystrokes in EEPROM and passes the self-test.

3-46