Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 7 of 14

9710 and 9720 Wedge Readers User's Manual, pages 61 to 70

Pages 61 to 70 of 138

The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 9710

Page 61

Configuring the Reader

3

Disable

*$+CB0* *$+CB0*

To configure Code 39

1. Scan this bar code. Accumulate/Change Config/Code 39

*+/$+CB* *+/$+CB*

2. Scan one of the bar code parameters. Without Check

Code 39 Check

Digit†

Digit

HIBC Code 39

AIAG Check Digit

*1*

*2*

*3*

*4*

*1*

*2*

*3*

*4*

3. Scan the bar code parameter you want (optional). Discard Check Digit

Retain/Transmit Check Digit †

*0*

*1*

*0*

*1*

4. Scan the bar code parameter you want (optional). Non-Full ASCII

Full ASCII †

Mixed Full ASCII

*0*

*1*

*2*

*0*

*1*

*2*

5. Scan this bar code. Exit Accumulate

*-/* *-/*

3-27

Page 62

9710 and 9720 Wedge Readers User’s Manual

Example: Defining Code 39

The following example configures the reader to decode non-full ASCII Code 39 with a check digit and transmits the check digit and the data to the workstation. 1. Scan this bar code to enable the accumulate feature and configure Code 39. Accumulate/Change Config/Code 39

*+/$+CB* *+/$+CB*

2. Scan the Code 39 check digit bar code to decode bar codes with check digits. Code 39 Check Digit

*2* *2*

3. Scan the Retain/Transmit Check Digit bar code to keep the check digit when transmitting the data to the workstation. Retain/Transmit Check Digit †

*1* *1*

4. Scan the Non-Full ASCII bar code to keep the reader from decoding full ASCII code. Non-Full ASCII

*0* *0*

5. Scan this bar code to to exit the accumulate feature and modify the configuration. Exit Accumulate

*-/* *-/*

3-28

Page 63

Configuring the Reader

3

Code 49 Code 49 is a multi-row symbology for high-density data. The last characters in each row are used for row checking, and the last two characters of the symbol are used for overall checking. Disable Code 49 †

Enable Code 49

*$+CJ0*

*$+CJ1*

*$+CJ0*

*$+CJ1*

Using Function Codes With Code 49

Function codes signal predefined data string placement in a Code 49 bar code. When a wedge reader encounters a function code, the reader replaces the function code with the defined string before transmitting the data to the workstation. This ability allows a single Code 49 symbol to contain several different variable length data fields. Function Code 1

Use this function code to identify a data system.

Disable Function Code 1

†

*$+CK* *$+CK*

To configure Function Code 1

1. Scan this bar code. Enter Accumulate Mode/Function Code 1

*+/$+CK* *+/$+CK*

2. Scan one to two characters from the full ASCII bar code chart. 3. Scan this bar code. Exit Accumulate Mode

*-/* *-/*

3-29

Page 64

9710 and 9720 Wedge Readers User’s Manual

Function Code 2 Use this function code to indicate the end of a data field. The default setting is <CR><LF> (Carriage Return Line Feed). Disable Function Code 2

*$+CL* *$+CL*

To configure Function Code 2

1. Scan this bar code. Enter Accumulate Mode / Function Code 2

*+/$+CL* *+/$+CL*

2. Scan one to two characters from the full ASCII bar code chart. 3. Scan this bar code. Exit Accumulate Mode

*-/* *-/*

Code 93 The Code 93 character set supports the 128 character full ASCII set. Disable

†

Enable

*$+CF0*

*$+CF1*

*$+CF0*

*$+CF1*

3-30

Page 65

Configuring the Reader

3

Code 128 and ISBT 128

Code 128 This symbology encodes the full ASCII character set of 128 characters.

If you select • enable standard, all Code 128 symbols are decoded (including UCC/EAN 128) and the Function 1 character is ignored. • enable UCC/EAN 128 (and a Function 1 character immediately follows the Code 128 start character), the symbols are decoded per UCC/EAN 128 specifications. That is, the Function 1 character that follows the start character is translated to the symbology identifier “]C1” and all subsequent Function 1 characters are translated to an ASCII <GS>. • enable UCC/EAN 128 (and a Function 1 character does not immediately follow the Code 128 start character), all Function 1 characters are ignored and the symbols are decoded as if they were Code 128. Note: Since the <GS> character is not a valid keyboard key, the reader substitutes a default character from the keyboard. See “Customizing ASCII to Keyboard Equivalents” later in this chapter. ISBT 128 This symbology is a variation of Code 128 that was developed by the International Society of Blood Transfusion (ISBT) for the bar code labeling of whole blood and blood products. ISBT 128 supports concatenation (linking) of two bar codes. Pairs of concatenated ISBT 128 bar codes can be decoded from a single scan of a laser scanner or wand. ISBT 128 has two configurable options.

The first option enables ISBT 128 concatenation with or without a symbology identifier at the beginning of the decoded output. If the symbology identifier feature is enabled: ]C0 indicates a non-concatenated read of an ISBT 128 bar code.

]C4 indicates that ISBT 128 concatenation is enabled and that a concatenated bar code has been read.

If the symbology identifier feature is not enabled, ]Cx is not sent to the host. Valid bar codes must contain an appropriate ISBT 128 data identifier in either case. 3-31

Page 66

9710 and 9720 Wedge Readers User’s Manual

The second option configures the read priority of a laser scanner to decode non-concatenated bar codes: High sets the scanner to ignore non-concatenated bar codes four times before reading the code. Low sets the scanner to ignore non-concatenated bar codes two times before reading the code. Disable sets the scanner to read a non-concatenated bar code on the first pass.

Note: Any time a successful read of a concatenated bar code occurs while the scanner is discarding non-concatenated bar code reads, the concatenated data will be sent to the host. When using a wand, concatenated or nonconcatenated bar code data will always be sent to the host. Note: When any form of ISBT 128 decoding is enabled, conventional Code 128 bar codes are not decoded. Disable

Enable ISBT 128 With Concatenation

*$+CH0*

*$+CH3*

*$+CH0*

*$+CH3*

†

Enable ISBT 128 With Concatenation and Enable Standard Code 128

Symbology Identifier

*$+CH1*

*$+CH4*

*$+CH1*

*$+CH4*

Enable UCC/EAN 128

*$+CH2* *$+CH2*

3-32

Page 67

Configuring the Reader

3

ISBT 128 Voting Options High

†

Disable

*$+CH5*

*$+CH7*

*$+CH5*

*$+CH7*

Low

*$+CH6* *$+CH6*

Code 16K Code 16K has up to 16 rows of characters in one symbol. Each row starts and ends with a single character identifying that particular row and scan direction. There are two overall symbol check characters. Disable Code 16K †

Enable Code 16K With Function Code 1

*$+CP0*

*$+CP2*

*$+CP0*

*$+CP2*

Enable Code 16K

*$+CP1* *$+CP1*

3-33

Page 68

9710 and 9720 Wedge Readers User’s Manual

Codabar Codabar is a variable length, discrete, self-checking code. This character set is limited to 16 data characters. American Blood Commission (ABC) Codabar requires that start/stop code representations are retained. As a result, configuration CD10 is an illegal configuration option. Codabar has two parameters.

To define Codabar 1. Scan this bar code. Accumulate/Change Config/Codabar

*+/$+CD* *+/$+CD*

2. Scan one of the bar code parameters. Disable†

American Blood Commission (ABC)

*0*

*1*

*0*

*1*

Standard

Concatenated

*2*

*3*

*2*

*3*

3. Scan one of the bar code parameters. Retain DC1-DC4 Discard Start/Stop

Retain ABCD Start/Stop

Start/Stop

*0*

*1*

*2*

*0*

*1*

*2*

4. Scan this bar code Exit Accumulate

*-/* *-/*

3-34

Page 69

Configuring the Reader

3

Example: Defining Codabar

The following example configures the reader to decode concatenated Codabar with four stop/start characters designated as A, B, C, and D. Concatenate combines two bar code labels into one data record. 1. Scan this bar code to enable the accumulate feature and to configure Codabar. Accumulate/Change Config/Codabar

*+/$+CD* *+/$+CD*

2. Scan this bar code to enable concatenation. Concatenated

*3* *3*

Concatenation causes the reader to read two bar codes and combine them into one data record. The stop code of the first bar code must be the same as the start code of the second bar code. 3. Scan the Retain ABCD Start/Stop bar code to decoded bar codes that have start/stop characters designated as A B C D. Retain ABCD Start/Stop

*1* *1*

4. Scan this bar code to prompt the reader to exit the accumulate feature and modify the configuration. Exit Accumulate

*-/* *-/*

3-35

Page 70

9710 and 9720 Wedge Readers User’s Manual

Interleaved 2 of 5 Code Interleaved 2 of 5 (I 2 of 5) Code uses both bars and spaces to encode numbers only. The code is continuous, self-checking, variable length, and must contain an even number of digits. Enabling Interleaved 2 of 5 Code automatically disables 2 of 5 Code. Note: Using the variable length without a check digit configuration can cause substitution errors. Disable

Case Code (6 or 14 Digits)

*$+CA0*

*$+CA98*

*$+CA0*

*$+CA98* Variable Length With Modulus 10

Variable Length Without a Check Digit

Check Digit †

*$+CA97*

*$+CA99*

*$+CA97*

*$+CA99*

To configure fixed length I 2 of 5 Code from 2 to 32 digits (even numbers).

1. Scan this bar code. Accumulate/Configure/I 2 of 5

*+/$+CA* *+/$+CA*

2. Scan an even number between 2 and 32.

*1*

*2*

*3*

*4*

*1*

*2*

*3*

*4*

*6*

*8*

*0*

*6*

*8*

*0*

3-36