Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 6 of 14

9710 and 9720 Wedge Readers User's Manual, pages 51 to 60

Pages 51 to 60 of 138

The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 9710

Page 51

Configuring the Reader

Disable Preamble B

3

†

*$+AB* *$+AB*

To define preamble B 1. Scan this bar code. Enter Accumulate Mode/Preamble B

*+/$+AB* *+/$+AB*

2. Scan this bar code. Begin Preamble B Character

*/B* *"*

3. Scan 1 to 25 characters on the full ASCII bar code chart to build Preamble B. 4. Scan this bar code. End Preamble B Character

*/B* *"*

5. Scan this bar code. Exit Accumulate Mode

*-/* *-/*

3-17

Page 52

9710 and 9720 Wedge Readers User’s Manual

Example: Defining a Preamble

The following example creates a preamble containing the word TEST. When the reader transmits data to the workstation, the data will be preceded by the word TEST. 1. Scan this bar code to enable the accumulate feature and to configure preamble A. Accumulate/Change Config/Preamble A

*+/$+AA* *+/$+AA*

2. Scan this bar code to begin entering preamble data. Beginning of Data

*/B* *"*

3. Scan the letters T E S T from the full ASCII chart at the end of this manual. This is preamble A that transmits with every data record. 4. Scan this bar code to end entering preamble A data. End of Data

*/B* *"*

5. Scan this bar code to to exit the accumulate feature and modify the configuration. Exit Accumulate

*-/* *-/*

6. Scan this bar code.

*DATA* *DATA*

The workstation monitor displays TESTDATA.

3-18

Page 53

Configuring the Reader

3

Postamble This parameter is added to the end of data you transmit to the workstation. The postamble can consist of any combination of characters from the full ASCII chart at the end of this manual. Common postambles include cursor controls like tabs or a carriage return and a line feed. The postamble characters are saved in EEPROM. Note: If you are using quotes (") in your data string, refer to the note on page 3-15. Disable

†

*$+AC* *$+AC*

To define the postamble

1. Scan this bar code. Accumulate/Change Config/Postamble

*+/$+AC* *+/$+AC*

2. Scan this bar code. Beginning of Data

*/B* *"*

3. Scan 1 to 25 characters on the full ASCII chart to build the postamble. 4. Scan this bar code. End of Data

*/B* *"*

3-19

Page 54

9710 and 9720 Wedge Readers User’s Manual

5. Scan this bar code. Exit Accumulate

*-/* *-/* Example: Defining a Postamble

The following example creates the postamble TEST. When the reader transmits data to the workstation, the record is followed by TEST. 1. Scan this bar code to enable the accumulate feature and to configure a postamble. Accumulate/Change Config/Postamble

*+/$+AC* *+/$+AC*

2. Scan this bar code to begin entering the postamble characters. Beginning of Data

*/B* *"*

3. Use the full ASCII chart to scan the bar codes for the word TEST. 4. Scan this bar code to end the postamble data. End of Data

*/B* *"*

5. Scan this bar code to exit the accumulate feature and modify the configuration. Exit Accumulate

*-/* *-/*

3-20

Page 55

Configuring the Reader

3

6. Scan this bar code.

*DATA* *DATA*

The workstation monitor displays DATATEST.

Scanner Trigger This parameter sets the Triggering mode to level or edge. Level triggering When you pull the scanner trigger, the laser turns on and stays on until you release the trigger. Edge triggering When you pull the scanner trigger, the laser turns on and stays on. When you pull the trigger a second time, the laser turns off. If the laser is left on, the Scanner Timeout parameter turns the laser off. Edge triggering is often used for remote triggering. Level

†

Edge

*$+SC0*

*$+SC1*

*$+SC0*

*$+SC1*

Scanner Mode

This parameter sets the scanner to One-shot or Auto-trigger mode. One-shot mode

The laser scanner reads one bar code per trigger-event. The laser scanner reads multiple bar codes per trigger-event, beeps, and transmits the bar code data separately. Auto-trigger mode

A trigger event occurs each time the laser is turned on. One-shot†

Auto-trigger

*$+SB0*

*$+SB1*

*$+SB0*

*$+SB1*

3-21

Page 56

9710 and 9720 Wedge Readers User’s Manual

Scanner Timeout

This parameter defines the maximum length of time that the laser scanner stays on during a single triggering event. During normal operation, the scanner turns off if you do not scan a bar code within the selected length of time. No timeout †

*$+SA0* *$+SA0* To define the scanner timeout

1. Scan this bar code. Accumulate/Change Config/Scanner Timeout timeout

*+/$+SA* *+/$+SA*

2. Scan a number between 1 and 60 (seconds).

*1* *2* *3* *4* *5* *1*

*2*

*3*

*4*

*5*

*6* *7* *8* *9* *0* *6*

*7*

3. Scan this bar code. Exit Accumulate

*-/* *-/*

3-22

*8*

*9*

*0*

Page 57

Configuring the Reader

3

Voting

This paramter defines the number of scans from the same bar code that must be decoded correctly for a “good read.” If you disable voting, the reader accepts the first “good read.” Intermec recommends that you disable voting if you are scanning good quality bar codes. When you enable voting, the reader decodes the same bar code multiple times during a single-trigger event and compares the decoded information a specific number of times before signalling a “good read.” To improve scanning performance (but increase the possibility of substitution errors), set the voting low to reduce the number of decodes. To provide extra data security (but slow performance especially on poor quality bar codes), set the voting high. The specific number of comparisons in low and high voting is defined in each bar code symbology. For example, when you are scanning Code 39 with voting set to low, two successive matching decodes are required. When voting is set to high, three successive matching decodes are required. Enabling voting is important when scanning poor quality bar codes that may cause substitution errors. Note: This parameter applies only when using a laser scanner with the reader. Disabled†

High

*$+SR0*

*$+SR2*

*$+SR0*

*$+SR2*

Low

*$+SR1* *$+SR1*

3-23

Page 58

9710 and 9720 Wedge Readers User’s Manual

Bar Code Symbologies This section defines the parameters for the various bar code symbologies the reader decodes. Some of the codes have more than one parameter. The dagger (†) indicates the default setting. For more information on bar code symbologies, refer to The Bar Code Book (Intermec P/N 051241).

Code 11 The Code 11 character set includes ten digits and the dash symbol. This code is not self-checking; data security is obtained by using one or two check digits. Disable†

Two Check Digits

*$+CG0*

*$+CG2*

*$+CG0*

*$+CG2*

One Check Digit

*$+CG1* *$+CG1*

Code 39 Code 39 is an alphanumeric code that is discrete, variable length, and self-checking. The Code 39 non-full ASCII character set includes 43 characters (a start/stop character, ten digits, the uppercase letters of the alphabet, space, and six symbols). The Code 39 full ASCII character set includes all 128 characters of the ASCII character set (listed in the Appendix). The Code 39 configuration has three parameters; the second and third parameters are optional. The first parameter defines the check digit. Code 39 provides for a modulus 43 check digit. The weighted check digit is used for Automobile Industry Action Group (AIAG) bar codes. Enabling Health Industry Bar Code (HIBC) Code 39 automatically disables full ASCII and enables check digit transmission.

3-24

Page 59

Configuring the Reader

3

The second parameter determines whether the reader transmits the check digit to the workstation or discards the check digit. A check digit is used for performing a mathematical check to ensure the accuracy of the message. The third parameter can be set to non-full ASCII, mixed full ASCII, or full ASCII. The Code 39 character set can physically encode 43 data characters: A - Z, 0 - 9, %, $, -, +, /, . (period), and the space character. In non-full ASCII Code 39, the reader interprets the bar code data character for character. For example, the reader interprets the bar code data “123+ABC” as “123+ABC”. Full ASCII Code 39 encodes all 128 ASCII characters by using $, %, /, and +, along with an upper case letter, to represent a full ASCII character. For example, $A = <SOH>, %A = <ESC>, /A = !, and +A = a. For a complete list of the full ASCII character set, see the ASCII Characters table on page A-7. In full ASCII Code 39, the reader interprets the bar code data by substituting full ASCII characters for valid ASCII character pairs. For example, the reader interprets the bar code data “123+ABC” as “123aBC”. The following example shows the different ways the reader interprets the bar code data $%a. Some bar code printers encode $%a as:

*$%+A* *$%+A*

While other bar code printers encode $%a as:

*/D/E+A* */D/E+A*

3-25

Page 60

9710 and 9720 Wedge Readers User’s Manual

If you configure the reader for: The output from the two bar code examples are the character in the bar code: $%+A and /D/E+A, respectively. Use this configuration if you do not want the reader to evaluate any valid full ASCII character pairs. Non-full ASCII

The first bar code example will not decode because each character (with the exception of upper case letters and numbers) must be encoded with the appropriate full ASCII character pair. The second bar code example will output $%a. Full ASCII

Use this configuration if you want the reader to: • with full ASCII evaluate bar codes character pairs, and

• read only bar codes encoded with full ASCII character pairs (as in the second example).

Mixed full ASCII The reader evaluates both of the bar code examples as $%a. Use this configuration if you want the reader to:

• evaluate bar codes with full ASCII character pairs, and

• read bar codes regardless of how the bar code is encoded.

Note: If you want the reader to evaluate bar codes differently than the nonfull ASCII configuration, mixed full ASCII is the most common choice. Note: If you cannot determine how your bar codes are printed, configure the reader for mixed full ASCII. Mixed full ASCII decodes all Code 39 bar codes. Note: If you are scanning bar codes on the Code 39 full ASCII chart and the workstation monitor displays incorrect characters (for example, +A instead of a), the reader is configured for Code 39 non-full ASCII. Configure the reader for Code 39 full ASCII or mixed full ASCII, to correctly decode all of the Code 39 full ASCII bar codes.

3-26