Page 41

Configuring the Reader

3

• For Data Entry keyboards, letters are converted to numbers or numbers to letters. (A Data Entry keyboard produces uppercase characters when you press the letter keys and numbers or symbols when you press the left Shift and letter keys.) When using a Data Entry keyboard, use WL0 for alpha mode, and WL1 for numeric/symbol mode. • Each time you scan a bar code, the workstation keyboard toggles Caps Lock mode. • If the keyboard is in Caps Lock mode, the reader transmits Shift key press-and-release codes to produce uppercase alpha characters that slow down data transmission. Disable†

Enable

*$+WL0*

*$+WL1*

*$+WL0*

*$+WL1*

Command Processing This parameter disables or enables all reader commands except for the Change Configuration command. For example, you can disable multiple-read bar codes so they are treated as regular bar codes. Disable All Reader Commands

Enable All Reader Commands †

*$+DC0*

*$+DC1*

*$+DC0*

*$+DC1*

To configure Command Processing 1. Scan this bar code. Accumulate/Change Config/Command Processing

*+/$+DC* *+/$+DC*

2. Scan this bar code. Beginning of Data

*/B* *"* 3-7

Page 42

9710 and 9720 Wedge Readers User’s Manual

3. Scan the bar code combination to build the reader command. Enter Accumulate

Exit Accumulate

*+*

*/*

*-*

*/*

*+*

*/*

*-*

*/*

Backspace

Clear

*-*

*+*

*-*

*-*

*-*

*+*

*-*

*-*

Reset

Default Config

*-*

*.*

*.*

*+*

*-*

*.*

*.*

*+*

Run Program (9720 only)

*/*

*/*

*/*

*/*

Multiple-Read

* * * *

Transmit Message (9720 only)

*.*

*.*

*$*

*.*

*.*

*.*

*$*

*.*

4. Disable/enable the reader command. Disable

Enable

*0*

*1*

*0*

*1*

Repeat steps 3 and 4 if you are disabling/enabling more than one command. 5. Scan this bar code. End of Data

*/B* *"*

3-8

Page 43

Configuring the Reader

3

6. Scan this bar code. Exit Accumulate

*-/* *-/* Example: Disabling/Enabling Reader Commands

This example disables the default configuration command and special processing of multiple-read bar codes to prevent the reader from accidentally returning to the default configuration. Also, when you scan a multiple-read bar code, the data is sent to the workstation instead of being held in the reader buffer. 1. Scan this bar code to enable the accumulate feature and configure command processing. Accumulate/Change Config/Command Processing

*+/$+DC* *+/$+DC*

2. Scan this bar code. Beginning of Data

*/B* *"*

3. Scan the Default Config bar code. Default Config

*.* *+* *.*

*+*

4. Scan this bar code to disable the Default Configuration command. Disable

*0* *0*

3-9

Page 44

9710 and 9720 Wedge Readers User’s Manual

5. Scan this bar code. Multiple-Read

* * * *

6. Disable the Multiple-Read command. 7. Scan this bar code to end Command Processing. End of Data

*/B* *"*

8. Scan this bar code to exit the accumulate feature and modify the configuration. Exit Accumulate

*-/* *-/*

To enable these commands, repeat the above steps, but scan the Enable bar code instead of the Disable bar code. If you want to enable all commands, scan the Enable All Reader Commands bar code. You can disable/enable any number of commands in one operation.

Data Redirection This parameter applies only to the 9720 and defines the routing for information the reader receives. For example, one parameter routes serial port data to the workstation and input device data to the serial port. When the reader redirects data through the serial port, you should define the TXEOM parameter. See Chapter 4 for more information on configuring TXEOM. Input Device and Serial Port Data Sent to Workstation †

*$+DR0* *$+DR0*

3-10

Page 45

Configuring the Reader

3

Input Device Data Sent to Serial Port; Serial Port Data Sent to Workstation

*$+DR1* *$+DR1* Input Device Data Sent to Serial Port and Workstation; Serial Port Data Sent to Workstation

*$+DR2* *$+DR2* Input Device Data Sent to Serial Port Only (Workstation Unaffected)

*$+DR3* *$+DR3*

Wait Character This parameter defines the wait character and works with the Wait Time parameter. For example, the default wait character is a Carriage Return (<CR>) - any time the reader sends a <CR> to the workstation, the reader waits a specified time (wait time) before it transmits the next character to the workstation. To disable the wait character, set Wait Time to No Delay (see the following section, “Configuring the Wait Time”). To configure the wait character

1. Scan this bar code. Enter Accumulate Mode/Wait Character

*+/$+WK* *+/$+WK*

2. Scan this bar code. Beginning of Data

*/B* *"*

3-11

Page 46

9710 and 9720 Wedge Readers User’s Manual

3. Scan a wait character from the full ASCII bar code chart. 4. Scan this bar code. End of Data

*/B* *"*

5. Scan this bar code. Exit Accumulate Mode

*-/* *-/*

Wait Time This parameter defines the time the wedge reader waits after receiving the wait character. You can choose No Delay or configure a wait time from 1 to 60 seconds. No Delay

†

*$+WJ0* *$+WJ0*

To configure a wait time

1. Scan this bar code. Enter Accumulate Mode/Wait Time

*+/$+WJ* *+/$+WJ*

2. Scan the number of seconds (1-60) for the wait time.

*1* *2* *3* *4* *5* *1*

*2*

*3*

*4*

*5*

*6* *7* *8* *9* *0* *6*

3-12

*7*

*8*

*9*

*0*

Page 47

Configuring the Reader

3

3. Scan this bar code. Exit Accumulate Mode

*-/* *-* Example: Wait Configuration

The following example defines a wait character and a wait time. After you scan the wait character, the reader inserts the wait time before transmitting the remaining data. 1. Scan this bar code to enable the accumulate feature and to configure a wait character. Enter Accumulate Mode/Wait Character

*+/$+WK* *+/$+WK*

2. Scan this bar code to configure the wait character. Begin Wait Character

*/B* *"*

3. Scan the number 3 from the full ASCII chart. This is the wait character. 4. Scan this bar code to end the wait character configuration. End Wait Character

*/B* *"*

5. Scan this bar code to exit the accumulate feature and modify the configuration. Exit Accumulate Mode

*-/* *-/*

3-13

Page 48

9710 and 9720 Wedge Readers User’s Manual

6. Scan this bar code to configure the wait time. Enter Accumulate Mode/Wait Time

*+/$+WJ* *+/$+WJ*

7. Scan these bar codes to configure the wait time for ten seconds.

*1*

*0*

*1*

*0*

8. Scan this bar code to to exit the accumulate feature and modify the configuration. Exit Accumulate Mode

*-/* *-*

9. Scan this bar code. 123DATA

*123DATA* *123DATA*

When you scan this bar code, the workstation monitor displays 123, waits ten seconds, and then displays DATA directly following the 123. Whenever you scan a 3, the reader waits 10 seconds before continuing data transmission to the workstation.

3-14

Page 49

Configuring the Reader

3

Intercharacter Delay This parameter adds a time delay to the characters transmitted to the workstation. (The reader also uses a minimum, workstationdependent, delay between all transmitted characters.) 0 msec

†

50 msec

*$+WI0*

*$+WI4*

*$+WI0*

*$+WI4*

5 msec

100 msec

*$+WI1*

*$+WI5*

*$+WI1*

*$+WI5*

10 msec

200 msec

*$+WI2*

*$+WI6*

*$+WI2*

*$+WI6*

20 msec

500 msec

*$+WI3*

*$+WI7*

*$+WI3*

*$+WI7*

Preamble This parameter precedes data you transmit to the workstation. The preamble can consist of any combination of characters on the full ASCII chart. Common preambles include a data location number or an operator number. The preamble characters are saved in EEPROM. Note: Quotes (") are used to indicate the beginning and end of data strings within a command. If you want to include a quote as part of the data, you must enter the quote character twice. The double quote is interpreted by the reader as a character and not the end of the data string.

3-15

Page 50

9710 and 9720 Wedge Readers User’s Manual

Scan

Reader Interpretation

"test" test

""test""

"test"

"test""test" test"test

Disable Preamble A

†

*$+AA* *$+AA*

To define preamble A 1. Scan this bar code. Accumulate/Change Config/Preamble A

*+/$+AA* *+/$+AA*

2. Scan this bar code. Beginning of Data

*/B* *"*

3. Scan 1 to 25 characters on the full ASCII chart to build preamble A. 4. Scan this bar code. End of Data

*/B* *"*

5. Scan this bar code. Exit Accumulate

*-/* *-/*

3-16