For the Intermec 9710

Page 31

Operating the Reader

2

Using Reader Commands You use the reader to complete specific tasks by scanning bar codes that contain one or more commands. Commands are run in the order they are located in the command string. Command processing stops with the first invalid command or at the end of the string. You can use the following commands with your wedge reader: Backspace (Destructive)

This command deletes the last character of an accumulated data record. If there is no accumulated data, the command is invalid. Backspace

*-+* *-+*

Change Configuration This command changes the reader configuration parameters. The Change Configuration command precedes one or more configuration commands in a command string or record. When this command runs, reader parameters are modified, the changes are saved in memory, and the reader is reset to allow the changes to take effect. Change Configuration

*$+* *$+*

Clear This command deletes an entire accumulated data record. If there is no accumulated data, the command is invalid. Clear

*--* *--*

2-5

Page 32

9710 and 9720 Wedge Readers User’s Manual

Default Configuration This command returns the reader to the factory settings and performs a self-test. See Chapter 3 for a list of reader default settings. Default Configuration

*.+* *.+*

Note: This command does not reset the workstation type.

Enter This command transmits accumulated data as a data record to the workstation. The Enter command is implied when you scan regular bar codes (bar codes without a leading space). If data records are not accumulated or present in a regular bar code, then a null or empty data record is transmitted to the workstation. Enter

** **

Enter Accumulate This command adds all subsequent scanned data to the current data buffer until the count exceeds 256 characters, an Enter bar code is scanned, or an Exit Accumulate bar code is scanned. Data exceeding 256 characters causes the reader to emit three low beeps and rejects the last bar code read. Enter Accumulate

*+/* *+/*

2-6

Page 33

Operating the Reader

2

Exit Accumulate This command exits the accumulate feature, transmits the accumulated data, and clears the data buffer. The reader automatically exits Accumulate mode whenever the reader is reset. Exit Accumulate

*-/* *-/*

Reset This command runs the self-test process. Any commands in a command string that follow the Reset command are lost. Reset

*-.* *-.*

Transmit Message This command applies only to the 9720 and transmits the exact solicitation message (no characters are added) from the 9720 serial port. Refer to Chapter 4 for more information about the Solicitation Message parameter and the 9720 serial port. Transmit Message

*..$.* *..$.*

2-7

Page 34

9710 and 9720 Wedge Readers User’s Manual

External Headphone/Speaker Jack

If you use the reader in a noisy environment, you can use a miniature-plug headphone or an amplified, self-powered speaker to hear the reader status beeps. The headphone/speaker jack is labeled “audio” on the reader rear panel. 9720 Serial Port

The 9720 Wedge Reader has an RS-232 serial port on the rear panel. You can connect a portable reader or scale to the serial port and transfer data from the portable reader or scale through the reader to the workstation. Refer to Section 4 for information on transferring data and configuring the serial port. Status Beeps

The reader speaker emits one or more beeps to indicate status conditions.

Beep

Status

L

Valid command or valid data accumulated

H

Valid data entered

HL

Keystroke not stored in EEPROM

LLL

Invalid command or data

HLH

I/O error

LLLL

Self-test passes

LHLH

Self-test fails

E

Test and service mode entered

H = high beep

2-8

L = low beep

E = extra low beep

Page 35

3 Configuring the Reader

Page 36

This page is a scan with no text; see it in the PDF.

Page 37

Configuring the Reader

3

This chapter lists the factory set parameters, explains the parameters, and describes how to change these parameters.

Default Reader Configuration The factory configuration of the reader provides efficient and effective operation; however, you may need to modify the configuration to optimize reader performance in your operating environment. Configuration parameters include identifying bar codes, setting timeout and intercharacter delay lengths, selecting trigger modes, and defining preambles and postambles. The default reader configuration parameters are listed in the following table. An asterisk (*) indicates parameters that only apply to the 9720 Wedge Reader.

Parameter

Setting

Application Program

Standard Operation

Baud Rate*

9600

Beeper Volume

Loud beep

Caps Lock

Off

Command Processing

Enable all reader commands

Data Begin

No stripping

Data Bits*

7

Data End

No stripping

Data Identifiers

Disabled

Data Redirection*

Input device/serial port to workstation

Data Source

Scanner data

Echo*

Disabled

Flow Control*

XON/XOFF control

Intercharacter Delay (serial port)*

0 msec

Intercharacter Delay (wedge reader)

0 msec

Modify Look-Up Table

No modifications

Parity*

Even

Postamble

None

3-3

Page 38

9710 and 9720 Wedge Readers User’s Manual

Parameter

Setting

Preamble A

None

Preamble B

None

RXEOM*

Carriage return line feed

Scanner Mode

One-shot

Scanner Timeout

No timeout

Scanner Trigger Mode

Level

Solicitation Message*

No message

Stop Bits*

1

Terminal Type

Null

Timeout Delay*

2 sec

TXEOM*

Carriage return line feed

Voting

Disabled

Wait Character

Carriage return

Wait Time

No delay

Window

Serial port data

Bar Code Symbologies Code 11

Disabled

Code 39

Full ASCII, no check digit

Code 49

Disabled

Code 49 Function 1

Disabled

Code 49 Function 2

CR LF

Code 93

Disabled

Code 128

Disabled

ISBT 128

Disabled

Code 16K

Disabled

Codabar

Disabled

Interleaved 2 of 5

Variable length with check digit

2 of 5 Code

Disabled

Plessey

Disabled

MSI

Disabled

UPC A and E; EAN 8 and 13; supplementals

Enabled

3-4

Page 39

Configuring the Reader

3

To set the reader to the factory default configuration

• Scan this bar code. Default Configuration

*.+* *.+*

Before you begin configuring the reader, be sure you are using the correct terminal type configuration. If you are unable to scan the bar code for your workstation type, you can build the workstation configuration command. Consult your WIF guide for the workstation configuration number or call your Intermec representative for the number. To build the workstation configuration command

1. Scan this bar code. Accumulate/Change Config/Workstation Type

*+/$+TA* *+/$+TA*

2. Scan the number for your workstation type from the full ASCII chart at the back of this manual. For example, the IBM PC workstation configuration number is 1. 3. Scan this bar code. Exit Accumulate

*-/* *-/*

3-5

Page 40

9710 and 9720 Wedge Readers User’s Manual

Configuration Parameters Some of the procedures in this chapter require that you scan a bar code from the Code 39 full ASCII chart located at the back of this manual. When entering data following a command, the data should be enclosed in quotes (as described on page 3-15). The quotes allow the reader to distinguish between data and reader commands. The following parameters configure the reader to meet your needs. The dagger (†) indicates the factory default setting.

Beeper Volume This parameter sets the beeper volume or turns it off. Off

Loud†

*$+BV0*

*$+BV3*

*$+BV0*

*$+BV3*

Quiet

Lower Beeper Volume

*$+BV1*

*$+BV8*

*$+BV1*

*$+BV8*

Normal

Raise Beeper Volume

*$+BV2*

*$+BV9*

*$+BV2*

*$+BV9*

Caps Lock This parameter enables or disables Caps Lock on the reader. When the Caps Lock setting for the workstation keyboard and the reader agree (both enabled or both disabled), the characters in a scanned bar code are transmitted to the workstation in the same case as they are printed on the label. If the Caps Lock settings do not agree, one of the following symptoms may occur: • The reader transmits alpha characters to the workstation in the opposite case that prints on the label, or all characters appear as uppercase characters or lowercase characters.

3-6