For the Intermec 9710

Page 21

Getting Started

1

Using a Power Supply For most wand and scanner operations, the reader uses power from the workstation. If the workstation cannot supply the required power at +5V for the wand or scanner, the reader requires an additional power supply. Your WIF guide lists the workstations that require an external power supply. If your workstation requires a power supply with the reader, continue reading this section. Otherwise, skip to “Checking Connections” on page 1-8.

Is Additional Power Required? Refer to the list below for part numbers of power supplies that support various voltage requirements.

Voltage

Part Number

P100V 50 to 60 Hz, -15% to +10% P120V 50 to 60 Hz, -15% to +10% P230V 50 Hz, -15% to +10%

054183 054182 054184

To connect a power supply 1. Attach the power supply connector to the power supply receptacle on the reader rear panel.

pow er in aud io

Reader Connection Detail powe r audio input term inal keyb oard

12

3

1-7

Page 22

9710 and 9720 Wedge Readers User’s Manual

2. Place the PCB jumper on pins 2 and 3. keyb keyb oard oard

12

12

3

Without an external power supply.

3

With an external power supply.

pow er inpu audi o t term inal keyb oard

12

3

Note: Do not plug the power supply into the wall outlet until the reader is connected to the workstation and the keyboard, and you are ready to turn on the workstation.

Checking Connections You need to have the following items connected: • The reader to the workstation and keyboard using the proper cables. • The wand or scanner to the reader. • The power supply, if required, to the reader. (Make sure the PCB jumper is set correctly.)

1-8

Page 23

Getting Started

1

Applying Power You are now ready to apply power to the system. 1. If you are using a power supply, plug it into an AC wall outlet. 2. Turn on the workstation. Note: Do not enter data. The reader must be configured for your workstation type before you begin operating the reader.

Identifying the Workstation Type The default workstation configuration is a null configuration. It is very important that you configure the reader for your particular workstation type before operating the reader with the workstation. Locate your workstation type configuration bar code in the WIF guide and scan the bar code to configure the reader for your workstation. The reader emits four low beeps to indicate that the configuration was successful. The reader is now ready to read bar codes. If the reader emits a low/high/low/high beep sequence, the reader failed the self-test. Scan the Null Configuration bar code. Verify that you are using the correct workstation configuration bar code and scan the bar code. If the reader emits the low/high/low/high beep sequence again, contact your Intermec representative. Null Configuration

*$+TA3* *$+TA3*

If you are moving the reader to a different workstation, scan the Null Configuration bar code before moving the reader. After you install the reader, reconfigure the reader for that workstation. Note: Attempting to read bar codes before the workstation type has been identified causes the reader to operate improperly. If this occurs, cycle the power to the workstation and scan the appropriate workstation configuration bar code. 1-9

Page 24

9710 and 9720 Wedge Readers User’s Manual

Checking Communications Now you are ready to scan the test bar codes to check communications. The reader emits one high beep each time it successfully translates a bar code. The workstation monitor displays the data with the cursor immediately following the data.

To check communications 1. Scan this bar code: Test Label

*TEST LABEL* *TEST LABEL*

The workstation monitor displays TEST LABEL. 2. Scan this bar code: Test Label

*123456789* *123456789*

The workstation monitor displays 123456789. 3. Advance the cursor using the cursor control key or tab key on your keyboard to make it easier to see the data. 4. Scan this bar code: Test Label

*97XX READER* *97XX READER*

The workstation monitor displays 97XX READER. To further demonstrate the operation of the reader, scan any of the bar codes on the ASCII charts located at the back of this manual. These bar codes are in Code 39. The reader interprets the data and transmits it to the workstation monitor.

1-10

Page 25

Getting Started

1

Troubleshooting If you are unable to successfully transmit the test data, review the following checklist. ✓ Check workstation configuration. Cycle power and scan the bar code for the correct workstation type. ✓ Check the cable connections between the workstation and the reader and the reader and the input device. ✓ If you are using a power supply, check the power connection to the reader and the wall outlet. ✓ Verify that the PCB jumper on the reader is set correctly. ✓ Verify that the bar codes are good by scanning the bar codes with a reader that you know is good.

Mounting the Reader You can mount the reader vertically or horizontally using Velcro strips or screws.

To mount the reader using Velcro strips 1. Take one set of Velcro strips (leave the set connected), remove the adhesive backing from one side, and apply the set to the reader. Repeat this process with the second set of Velcro strips. 2. Remove the backing from the exposed side of the strips and firmly press the reader to the mounting surface. A good mounting surface is the side of your workstation monitor. 3. Carefully remove the reader from the mounting surface by separating the Velcro strips. Ensure that all four strips are firmly attached to their respective surfaces before remounting the reader.

1-11

Page 26

®

9710

9710 and 9720 Wedge Readers User’s Manual

To mount the reader using wood screws • For a more permanent mounting, use two #10 wood screws to attach the reader to a mounting surface. Ensure that the surface you select can handle the alteration. Do not attach the reader to the workstation monitor using wood screws.

®

9710

The wedge reader is now ready for operation.

1-12

Page 27

2 Operating the Reader

Page 28

This page is a scan with no text; see it in the PDF.

Page 29

Operating the Reader

2

The reader is easy to operate. To transmit bar code data to your workstation, you scan bar code labels that contain data, commands, or a combination of both. The data appears on your workstation monitor as if you entered it from the keyboard.

How to Use the Reader The reader uses two operating states: • Test and Service • Standard Operation Note: Some terminal emulation or network hardware or software can affect the way the workstation operates. This may affect wedge operation.

Test and Service Intermec customer service representatives (CSRs) use this mode to diagnose reader problems. The reader enters Test and Service mode automatically after a self-test failure. A self-test runs at power-on and after a reset. The reader emits a very low beep every 10 seconds to indicate it is in Test and Service mode. If the reader enters Test and Service, scan the bar code below. The reader resets and executes a self-test. If the self-test fails, the reader returns to Test and Service and you need to contact your Intermec representative. Reset Command

*-.* *-.*

Note: You can configure the reader and run commands when the reader is in Test and Service mode.

2-3

Page 30

9710 and 9720 Wedge Readers User’s Manual

The reader automatically enters Standard Operation after a successful self-test. Four low beeps indicates the reader is in Standard Operation mode. Standard Operation allows you to Standard Operation

• scan bar codes to enter data. • read and decode various bar code symbologies. • accumulate scanned data into one record. • transmit accumulated data. • add a preamble or a postamble to data. • build a record or a command. • configure serial port parameters (9720 only).

Reading Bar Codes The reader can distinguish between two types of bar codes: regular and multiple-read. A regular bar code always takes the form *data*. Typically, the bar code data is transmitted as soon as you scan the bar code. The asterisks (*) are the start and stop characters and are not transmitted or shown on the workstation monitor. Only the reader uses the asterisks to indicate the beginning and the ending points of a bar code. For example, scanning a bar code with the data *TB123* transmits TB123 to the screen. Regular bar codes

Multiple-read bar codes take the form *spacedata*, where “space” is an encoded space and data is the information you want to enter. Multiple-read bar codes are not transmitted to the workstation monitor immediately, but are held in the reader buffer until the reader receives a transmit command. Multiple-read bar codes allow a record or a command to be built from individual bar codes. Multiple-read bar codes

For example, scanning a bar code with the data * TB123* places TB123 in the reader buffer. The reader must receive a transmit command before the data is sent to the workstation. When you scan a transmit command (Enter), TB123 is transmitted to the workstation monitor. If you scan a regular bar code (like *456*), TB123456 is transmitted to the workstation. 2-4