For the Intermec 9710

Page 11

CODE39

Before You Begin

Before You Begin This section introduces you to standard warranty provisions, safety precautions, document formatting conventions, and sources of additional product information. A documentation roadmap is also provided to guide you in finding the appropriate information.

Warranty Information To receive a copy of the standard warranty provision for this product, contact your local Intermec support services organization. In the U.S. call 1-800-755-5505, and in Canada call 1-800-688-7043. Otherwise, refer to the Worldwide Sales & Service list that ships with this manual for the address and telephone number of your Intermec sales organization.

Safety Summary Your safety is extremely important. Read and follow all warnings and cautions in this book before handling and operating Intermec equipment. You can be seriously injured, and equipment and data can be damaged if you do not follow the safety warnings and cautions.

Do not repair or adjust alone Do not repair or adjust energized equipment alone under any circumstances. Someone capable of providing first aid must always be present for your safety.

First aid Always obtain first aid or medical attention immediately after an injury. Never neglect an injury, no matter how slight it seems.

Resuscitation Begin resuscitation immediately if someone is injured and stops breathing. Any delay could result in death. To work on or near high voltage, you should be familiar with approved industrial first aid methods.

ix

Page 12

9710 and 9720 Wedge Readers User’s Manual

CODE39

Energized equipment Never work on energized equipment unless authorized by a responsible authority. Energized electrical equipment is dangerous. Electrical shock from energized equipment can cause death. If you must perform authorized emergency work on energized equipment, be sure that you comply strictly with approved safety regulations.

About This Manual This manual contains information necessary to install, operate, configure, troubleshoot, and maintain the 9710 and 9720 Wedge Readers.

What You Will Find in This Manual This table summarizes the information in each chapter of this manual: For Information On

Refer To

Installing the reader

Chapter 1, “Getting Started.” This chapter tells you how to install the reader in your data collection system, configure the reader for your specific workstation, and check for communications.

Operating the reader

Chapter 2, “Operating the Reader.” This chapter explains the commands you need to use to operate the reader.

Configuring the reader

Chapter 3, “Configuring the Reader.” This chapter contains all of the configuration parameters that you can use to customize reader operation to meet your specific system needs.

Using the 9720 serial port

Chapter 4, “Configuring the 9720 Serial Port.” This chapter describes how to use the serial port on the 9720 reader to communicate with a portable reader or a scale.

Using the Data Edit application

Chapter 5, “Data Edit Application.” This chapter tells you how to use Data Edit to strip specific characters from a data record before transmitting that record to a workstation, portable reader, or scale.

Terms and Conventions The following special terms and conventions occur throughout this manual. x

Page 13

CODE39

Before You Begin

• “Wedge reader,” and “reader” refer to the 9710 and 9720 wedge readers. Unless specifically stated, all information in this manual applies to both reader models. • “9710” refers to the 9710 Wedge Reader. • “9720” refers to the 9720 Wedge Reader. • “Workstation” refers to a personal computer or other computer that communicates with the reader. • Commands and configuration parameters appear in the order you enter them into the reader with the following conventions: Convention

Description

<>

Angle brackets enclose mnemonic representations of ASCII control characters. For example, <ETX> represents the ASCII “End of Text” control character.

data

Italic text represents variable data, which you must replace with a real value. For example, n signifies a variable for which you must designate a constant value.

Ctrl

Bold text represents a key on your keypad. For example, Ctrl represents the Ctrl key and M represents the letter M key.

Ctrl-C

When two keys are joined with a dash, press them simultaneously. For example, if you see the command Ctrl-C, press the two keys at the same time.

Format Conventions for Bar Codes You can scan the bar codes listed in this manual to enter data or perform a command. The bar code labels in this manual are printed in the Code 39 symbology. Each bar code includes the name and human-readable interpretation. For example:

Change Configuration

Name

*$+*

Bar code (Code 39) Human-readable interpretation

*$+*

2010U.073 xi

Page 14

9710 and 9720 Wedge Readers User’s Manual

CODE39

The asterisks (*) at the beginning and end of the human-readable interpretation are the start and stop codes for a Code 39 bar code label. If you are creating bar code labels with a bar code utility, it may automatically supply the asterisks as the start and stop code, so that you only need to type the actual text of the command. You can also create and print configuration labels and reader command labels in Code 93, which has its own start and stop codes.

Other Intermec Manuals

The following manuals provide additional information about using the reader and working with bar codes. Manual

Intermec P/N

Data Communications Reference Manual

044737

The Bar Code Book by Roger C. Palmer

051241

9440/44/45 Trakker Operator’s Guide

053397

9440/44/45 Trakker User’s Manual

049273

9460 Trakker Operator’s Guide

053014

9460 Trakker User’s Manual

053012

9462 Trakker Operator’s Guide

053141

9462 Trakker User’s Manual

053143

Introduction to IRL Programming Manual

045025

IRL Programmer’s Reference Manual

048609 xii

Page 15

1 Getting Started

Page 16

This page is a scan with no text; see it in the PDF.

Page 17

Getting Started

1

The 9710 and 9720 Wedge Readers connect between the computer workstation and the workstation keyboard. The wedge reader transmits information from the bar codes you scan to the computer workstation. The bar code data displays on the monitor in the same format as if it was entered from the workstation keyboard. The wedge reader translates all of the 128 ASCII characters into valid keystrokes.

Preparing for Installation Your wedge reader package includes the following parts: • 9710 or 9720 Wedge Reader • Velcro fasteners Unpack the shipping carton and verify the contents with the packing slip. Keep the packing box; it is the approved shipping container for the reader. Use this box if you need to return the reader to Intermec. These items are packaged separately from the reader: • Wand or scanner • Adapter cable • Power supply (if required) The following figure shows a 9720 Wedge Reader installed in a typical data collection system. Only the 9720 Wedge Reader has a serial port that can connect to a portable reader or a scale.

1-3

Page 18

9710 and 9720 Wedge Readers User’s Manual

9720 Wedge Reader powe r

Power Supply audio input

Portable Reader termi nal keyb oard

12

3

Headset

ID AVORE OSU is EXP r light Laseted from ture Emit Aper this ER EVIT TE TOUION r OSITLase EXPiere cette Lum par rture Emisouve

45

15 ®

Scanner Workstation

Wand Scale Slot Scanner

Connecting the Reader to the Workstation There are two cables for connecting the reader to your workstation: a reader/keyboard cable that connects the keyboard to the reader and a reader/workstation cable that connects the reader to the workstation. Each cable has a ten-position modular connector to connect to the reader. The cable package contains a Wedge Interface (WIF) guide that provides information on configuring the reader for your workstation. Retain the WIF guide for future reference.

1-4

Page 19

Getting Started

1

Installing the Reader 1. Turn off the workstation and disconnect the keyboard cable from the workstation. 2. Connect the reader/workstation cable “PC/Terminal” connector to the keyboard connector on the workstation and connect the modular connector to the “terminal” connector on the reader. 3. Connect the reader/keyboard cable “Keyboard” connector to the workstation keyboard cable and connect the modular connector to the “keyboard” connector on the reader. The cable connectors only fit one way. If the connector does not fit, do not force it or you may damage the connector. The following figure shows how the reader connects to your workstation. Note: Do not use a cable extender with the reader cables. A cable extender will add noise to the line.

inpu t term inal keyb oard

12

3

Reader Connection Detail pow er aud io input termin al keyboa rd

Reader/Workstation Cable

12

3

Reader/Keyboard Cable

1-5

Page 20

9710 and 9720 Wedge Readers User’s Manual

Connecting an Input Device The reader can receive input from: • 1260-series wands • 1500-series scanners • 1461 CCD scanners • 1354 and 1355 bar code slot scanners The wands and scanners require a special cable or an adapter cable to connect to the ten-position modular connector on the rear panel of the reader. If you do not have the correct cable, call your Intermec representative.

To connect a wand or scanner to the reader • Connect the wand or scanner cable to the “input” modular connector on the reader rear panel. Make sure that the connector snaps into place securely.

owe r aud io r inpu audi o t term inal keyb oard

12

ID AVORE OSU is EXP r light Laseted from rture Emit Ape this ER EVIT TE TOUION r OSITLase EXPiere cette Lum par rture Emisouve

45

15

1-6 t

Connection Detail powe

® inpu

3 term inal k