The text of a manual · part 15 of 21
9570 Wedge Reader User's Manual: Section 6 - Scale Operation, pages 124 to 129
Pages 124 to 129 of 182, from 9570 Wedge Reader User's Manual
The original document is the PDF (1.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 9570
Page 124
Auxiliary Port Operation
Tabla 6-3 (Continued)
R§-232 Auxillary Port Parameters
Define End of Window Two:
Scan these labela:
1.enter configuration
2, Identify window two end
3. select position
4, enter data
5. exit configuration
MI *+f$
Accumulate /Enter Configuration Mode
AN a
End of Window Two
+*
Mn
Now scan a number from the Full ASCil chart to define the end position of window two.
Enter
Exit Configuralion
A On
The default position for end of window two is 1.
©1988 INTERMEC Corporation
Page 6-17
Page 125
SCALE OPERATION
Table 6-3 (Continued) AS-232 Auxillary Port Parameters
Define Message Two EOM Character:
Scan these labels:
1. entar configurallon
2 Identify window two EOM
3, select character
4. enter data
5. exit conilguration
$f
Accumulate/Enter Configuration Mode
MT
+ 4 Window Two EOM
ATA
Sean a character from the Full ASCII chart to define window two EOM. Usually CR or LF. Only one character allowed.
Enter Exit Configuration iN
The default EOM character is a CR (carriage return).
See page 6-3 for EOM character definition.
Page 6-18
©1998 INTERMEG Corporation
Page 126
Solicited Data
SOLICITED DATA
To sallcit the scale to tranamit data, send a pre-defined message to the scale. Thie solicitation message will be understood by the scale as a command to transmit. Typlcatly this ls a cammand to print or read.
An alternalive method of transmitting data from the scale Is to Initiate the transmission from the scale by pressing the PRINT pushbutton or closing an extemal switch on the scale. This data ls treated as unsolicited data and is always entered into window one.
Define Sollcitation Message
To define the solicitation messages, follow the steps In Tabla 6-4. The defined solicitatlon messages are atored In EEPROM; they remaln defined until changed, The sollcitation message Is IImited to a maximum of 15 characters. After the solicitation messages are dafined and stored in EEPROM, you must command the wedge to transmit the message. These commands are explained In Transmit Data in this section.
Table 6-4 Define Solicitation Messages Define Sollcitation Message One: Scan these labels:
1. Enable Accumulate/, ARAM *4/4+$*
2. Solicitation Message
Ove Det AOE A
3. Scan characters on Full ASCII chart to define string; minimum of 2 characters and maximum of 15 characters.
4. Scan enter Enter
*
©1988 INTERMECG Corporation Page 6-19
Page 127
SCALE OPERATION
Table 6-4 (Continued) Define Solicitation Messages Dafine Sollcitation Massage 2: Scan these labels:
1. Enable Accumulate/
Fu Sc aL
2. Solicitatlon Message
To Define ARNE
3. Sean characters on Full ASCII chart {o define string; minimum of 2 characters and maximum of 15 characters.
4. Enter data Enter
Transmit Solicitation Commands You are ready to sallcit data from the scale after you have defined the following:
® Baud rate, parity, number of stop bits and dala bis « Window Begin and End positions
« End of Message (EOM) character
» Solicllation Massage
To sollcit data from the scale, scan the Transmit Solicitation Massage One bar code label below. This commands the wedge to transmit the data defined in Sollcltation Message One.
The scale responds by sanding the data. The wedge inspects the incoming data, locates window one, strips characters not In window one, and transmits the remalning data to the workstation CRT.
To command the scale to transmit the data In window two, define Solicitation Massage Two and scan the Transmit Sollcitation Message Two bar code label.
Page 6-20 ©1988 INTERMEG Corporation
Page 128
Example
Transmit Solicitation Message One to Scale This command will send the predefined message to the scale, The wedge reader fs asking for aresponse. The responss will be treated as window one data.
Transmit Solicitation Message One
008000
Transmit Solleltation Message Two to Scale This command will send the predefined message to the scale. The wedge reader Is asking for aresponse. The response will be treated as window two data.
Transmit Solicllation Message Two
CARE A
$-
EXAMPLE
The following example illustrates the process to calculate the windaw positions, locate the EOM character, and determine the solicitallon messages for wedge reader configuration.
Scale Message Format Refer to the scale service manual for information about scale message format. The scale In this example sends out data In the following format:
{SOH} {NUL} {status 1} {7 diglt net weight} {7 digit gross welght} {CR}
Window Data The desired data Is the 7 digit net welght and the 7 digit gross weight. The net welght will be window one dala and the gross welght will be window two data.
Calculations
The example scale message format above was used to make tho following calculations.
©1988 INTERMEC Corporation Page 6-21
Page 129
SCALE OPERATION
Window One: The beginning position Is calculated by counting the charactera from the beginning of the record. Therefore, the begin position is 4. The ending position |s calculated by counting the characters from the end of the record, Therefore, the end position Is 9.
End of Message Character: CR (carlage return)
Solicitation Message One: The scale service manual lists the commands. The scale will transmit the data after recelving the ASCII character P which Is the command to print data. Define salicitation message one as P.
Window Two: The beginning position is calculated by counting the characters from the beginning of the record. Therefore, the beginning position Is 11. The ending position Is calculated by counting the characters from the end of tha record. Therefore, the end poaltion Is 2.
End of Message Character: CR (carriage return)
Solicitation Message Two: This message fs define as lhe ASCII character P which us the scales command to print data. In thls example the two sollcitation message ara tha same; however, thls is not required. The sallcitailon messages can contaln difierent commands.
Transmit Commands After the parametera have been defined In the wedge, scanning one of the two command labels (Transmit Sallcitation One or Transmit Solicitation Two) will cause the wedge to sallci data {rom the scale.
ADDITIONAL INFORMATION
For additional Information about using a scale with your wedge reader, request Application Note Number 10 from your local INTERMEC distributor.
Page 6-22 ©1988 INTERMEC Corporation