Auxiliary Port Operation

Tabla 6-3 (Continued)

R§-232 Auxillary Port Parameters

Define End of Window Two:

Scan these labela:

1.enter configuration

2, Identify window two end

3. select position

4, enter data

5. exit configuration

MI *+f$

Accumulate /Enter Configuration Mode

AN a

End of Window Two

+*

Mn

Now scan a number from the Full ASCil chart to define the end position of window two.

Enter

Exit Configuralion

A On

The default position for end of window two is 1.

©1988 INTERMEC Corporation

Page 6-17

Page 125 read from a scan by OCR; it may hold reading errors

SCALE OPERATION

Table 6-3 (Continued) AS-232 Auxillary Port Parameters

Define Message Two EOM Character:

Scan these labels:

1. entar configurallon

2 Identify window two EOM

3, select character

4. enter data

5. exit conilguration

$f

Accumulate/Enter Configuration Mode

MT

+ 4 Window Two EOM

ATA

Sean a character from the Full ASCII chart to define window two EOM. Usually CR or LF. Only one character allowed.

Enter Exit Configuration iN

The default EOM character is a CR (carriage return).

See page 6-3 for EOM character definition.

Page 6-18

©1998 INTERMEG Corporation

Page 126 read from a scan by OCR; it may hold reading errors

Solicited Data

SOLICITED DATA

To sallcit the scale to tranamit data, send a pre-defined message to the scale. Thie solicitation message will be understood by the scale as a command to transmit. Typlcatly this ls a cammand to print or read.

An alternalive method of transmitting data from the scale Is to Initiate the transmission from the scale by pressing the PRINT pushbutton or closing an extemal switch on the scale. This data ls treated as unsolicited data and is always entered into window one.

Define Sollcitation Message

To define the solicitation messages, follow the steps In Tabla 6-4. The defined solicitatlon messages are atored In EEPROM; they remaln defined until changed, The sollcitation message Is IImited to a maximum of 15 characters. After the solicitation messages are dafined and stored in EEPROM, you must command the wedge to transmit the message. These commands are explained In Transmit Data in this section.

Table 6-4 Define Solicitation Messages Define Sollcitation Message One: Scan these labels:

1. Enable Accumulate/, ARAM *4/4+$*

2. Solicitation Message

Ove Det AOE A

3. Scan characters on Full ASCII chart to define string; minimum of 2 characters and maximum of 15 characters.

4. Scan enter Enter

*

©1988 INTERMECG Corporation Page 6-19

Page 127 read from a scan by OCR; it may hold reading errors

SCALE OPERATION

Table 6-4 (Continued) Define Solicitation Messages Dafine Sollcitation Massage 2: Scan these labels:

1. Enable Accumulate/

Fu Sc aL

2. Solicitatlon Message

To Define ARNE

3. Sean characters on Full ASCII chart {o define string; minimum of 2 characters and maximum of 15 characters.

4. Enter data Enter

Transmit Solicitation Commands You are ready to sallcit data from the scale after you have defined the following:

® Baud rate, parity, number of stop bits and dala bis « Window Begin and End positions

« End of Message (EOM) character

» Solicllation Massage

To sollcit data from the scale, scan the Transmit Solicitation Massage One bar code label below. This commands the wedge to transmit the data defined in Sollcltation Message One.

The scale responds by sanding the data. The wedge inspects the incoming data, locates window one, strips characters not In window one, and transmits the remalning data to the workstation CRT.

To command the scale to transmit the data In window two, define Solicitation Massage Two and scan the Transmit Sollcitation Message Two bar code label.

Page 6-20 ©1988 INTERMEG Corporation

Page 128 read from a scan by OCR; it may hold reading errors

Example

Transmit Solicitation Message One to Scale This command will send the predefined message to the scale, The wedge reader fs asking for aresponse. The responss will be treated as window one data.

Transmit Solicitation Message One

008000

Transmit Solleltation Message Two to Scale This command will send the predefined message to the scale. The wedge reader Is asking for aresponse. The response will be treated as window two data.

Transmit Solicllation Message Two

CARE A

$-

EXAMPLE

The following example illustrates the process to calculate the windaw positions, locate the EOM character, and determine the solicitallon messages for wedge reader configuration.

Scale Message Format Refer to the scale service manual for information about scale message format. The scale In this example sends out data In the following format:

{SOH} {NUL} {status 1} {7 diglt net weight} {7 digit gross welght} {CR}

Window Data The desired data Is the 7 digit net welght and the 7 digit gross weight. The net welght will be window one dala and the gross welght will be window two data.

Calculations

The example scale message format above was used to make tho following calculations.

©1988 INTERMEC Corporation Page 6-21

Page 129 read from a scan by OCR; it may hold reading errors

SCALE OPERATION

Window One: The beginning position Is calculated by counting the charactera from the beginning of the record. Therefore, the begin position is 4. The ending position |s calculated by counting the characters from the end of the record, Therefore, the end position Is 9.

End of Message Character: CR (carlage return)

Solicitation Message One: The scale service manual lists the commands. The scale will transmit the data after recelving the ASCII character P which Is the command to print data. Define salicitation message one as P.

Window Two: The beginning position is calculated by counting the characters from the beginning of the record. Therefore, the beginning position Is 11. The ending position Is calculated by counting the characters from the end of tha record. Therefore, the end poaltion Is 2.

End of Message Character: CR (carriage return)

Solicitation Message Two: This message fs define as lhe ASCII character P which us the scales command to print data. In thls example the two sollcitation message ara tha same; however, thls is not required. The sallcitailon messages can contaln difierent commands.

Transmit Commands After the parametera have been defined In the wedge, scanning one of the two command labels (Transmit Sallcitation One or Transmit Solicitation Two) will cause the wedge to sallci data {rom the scale.

ADDITIONAL INFORMATION

For additional Information about using a scale with your wedge reader, request Application Note Number 10 from your local INTERMEC distributor.