SECTION 6 SCALE OPERATION

AUXILIARY PORT OPERATION Auxiliary Port Features

Scale Installation

Power Suppiles

AUXILIARY PORT CONFIGURATION Configuration Parameters Configuration Checklist

Configuratlon

SOLICITED DATA Define Sollcitation Message Transmit Solicitation Commands

EXAMPLE

Scale Message Format Window Data Calculations

Transmit Commands

ADDITIONAL INFORMATION

©1998 INTERMEC Corporation

Page 6-1

Page 109 read from a scan by OCR; it may hold reading errors

SCALE OPERATION

AUXILIARY PORT OPERATION

You can connect a counting or welghing scale to the wedge reader at the AS- 232 auxillary port. With a scale connected, you can transmit scale data to your workstation through the wedge reader. Operating with a scale will not change your workstation operation or the operation of the accessories you have connected to the wedge reader,

Auxiliary Port Features

The AS-232 auxiliary port has several special features that control the solicitation, raception, Interpretation, and transmission of scala data through the wedge to your workstation.

Window Mode: Window Mode is tailored for use with most scales, aspeclally small parts counting scales. Scales can send several types of information like count, weight, gross weight, tare weight, and date. Since scales usually send thelr data to printers, Ihe message contains non-printing contral characters; these characters are stripped out before the data is sent to the screen.

In Window Mode the wedge reader will: ‘ Search the incoming scale message for the pre-defined data.

° Strip contol characters, status words, and checksums {from the scale message.

° Appand pre-defined preamble, postamble, and message tenninator characters to window data (if desired).

e Transmit the data and appended characters to the workstation.

Methods of Transmission: There are three ways to command the scale to send data through the RS-232 line:

) The operator presses a key on the scale (PRINT}. Aswitch, axternal to the scale but wired to it, closes. The acale recelves a command through the RS-232 serlal line from the wedge.

The operator causes the scale to send the data with methods 1 and 2. In mathod 3 the wedge reader sollcits the scale requesting transmission of data. You must define the solicitation command and transmit the message to the scale.

Page 6-2 ©1988 INTERMEC Corporation

Page 110 read from a scan by OCR; it may hold reading errors

Auxiliary Port Operation

Windows: By defining the start and end positions of a section of data within the incoming scale message, the wedge is able to strip away the ramalning characters so that only desired data Is sent to the CAT screen. The saction contalning the desired data is called a window. Although only one window per message Is allowed, you may define two windows.

The start of the window Is determined by counting the characters from the beginning of the message; the end of ihe window Is determined by counting ihe characters from the end of the message. An example will explain:

You have a scale that sands out walght data In the following format: {SOH} {NUL} {status1 } {status2}{7 digit welght} {cksm1} {cksm2}{CR}

The data that you want gant to the screen is the 7 digit weight. Therefore, the window étart Is 5, and the window end is 4.

Data will be entered Into window two only if sollcitation message two was transmitted to the scale, All other Incoming data Is entered into window one. Data received by the wedge from the scale Initiated by depressing the PRINT pushbutton on the scale is considered to be unsolicited data; all unsolicited transmisslons are entered Into window one.

End of Message (EQM) Characters: Every massage from the scale will have the same character in the last position, Typlcally the EOM character Is a CR (carriage return) or a LF (line feed). H the scale transmits both a CR and a LF, only define the last character as the EOM character.

The wedge reader will search the transmission for thls character as a check for a complete transmission and use the data to calculate the end posillon of Ihe window. ,

$ee your scala manual or inspect the scale transmission in transparent mode to identify the EOM character. In transparent mode, the wedge will append any defined postambles or massage terminators to the scale transmission before sanding it to the workstallon CAT. °

Instrucilons for defining the EOM character for the wedge are Included In this section under Configuration.

©1988 INTERMEC Corporation Page 6-3

Page 111 read from a scan by OCR; it may hold reading errors

SCALE OPERATION

Sollcitation Messages: A solicitation message is a message sent from the wadge to ihe scale at any time. The solicitatan message commands the scale to fransmit data ihrough the RS-232 Interface to the wedge. Your scale service manual contains a list of tlhe commands with the ASCII character equivalent.

The wedge reader can solicit two messages from the scale, therefore, there are two solicilation messages that can be defined. Many scales transmit several piecas of data in a single record; these may be net weight, gross weight, tare weighi, date, or time. Each solicitation message corresponds to Its window. Solicliatian message one requests data in window one; solicitation message two requests data in window two.

These solicitatlon messages are stored in EEPROM and remaln defined until you change them. The maximum message tength is 15 characters each.

Unsolicited Messages: You can Initiate transmission of the scale data by pressing the PRINT pushbutton on the scale or by closing an external switch at ihe scale. This data Is unsolicited by the wedge and it always treated as window one data.

You must transmit solicitation message two to the scale to receive dala In window two.

Flow Control: Ciear-to-Send (CTS) will always be true when in Window Mode, except when the buffer is in danger of overtlowing. It will than go false until enough characters have been sent from the buffer to ihe CRT screen so mare data can be recelved from the sending device.

Timeout: The timeout will prevent ihe wedge reader [rom geting out of synchronization with ihe scales messages.

The message timeout is enabled with the receipt of the first character in the message. When the timeout expires, ihe buffer caunt (the count of ihe Incoming message) will be rasat to zero.

it data stops arriving before an EOM character Is racelved, the wedge reader will wait for the specified timeout period before indicating a fault. When the wedge reader receives the EOM, the window data will be sent to the screen. If not enough dalais received to fill the window, the error beep will sound and the fault status light will Illuminate. No data will ba transmitted.

Page 6-4 ©1988 INTERMEC Corporation

Page 112 read from a scan by OCR; it may hold reading errors

Auxiliary Port Operation

Scale Installation

Before you connect the scale to the wedge reader, itis necessary to connect the wedge to the worketatlon. Secilon 2 contalns wedge reader installation Information. You must also configure the wedge operating parameters.

Sectlon 3 contalns configuring Information.

Tabla 6-1 describes the pin assignment for the 25-pin Sub D connector for the wedge reader RS-232 auxiliary port. Refer to your scafe manufacturer installation and operation manuals for specific Information about the type of connector néeded to operate your scale with RS-232 Interlace.

Table 6-1 9570 Wedge Reader Connector

Pin: Assignment Signal Direction: Pin2 Transmit To reader

Ping Recaive From reader Pin4 RTS To reader

PinS CTS From reader

Pin 7 Ground

Pin 19* Exiemal AS-232 Nagalive Supply To reader

Pin 25* Extemal AS-232 Posilive Supply To reader

*Pins 18 and 25 are required for user-provided external power supplies.

Power Supplies

The wedge Ia sat at the factory for Internally supplied +5 volts power. However, you AS-232 interface may require a higher voltage. You can select from two INTERMEC power supplies or provide your own power supply.

INTERMEC Power Supply

INTERMEC Power Supplles supply £12 volls of power to the reader for accessories. The power supplies are equipped with connectors which are compatible with the reader rear panel connectors. The power supplies supply +12 valts unregulated power for RS-232 and +5 volls requlated power for reader accessories.

INTERMEC Power Supply 046791 Is 20 Watts and INTERMEC Power Supply 046792 is 45 Watts,

©1988 INTERMEC Corporation Page 6-5

Page 113 read from a scan by OCR; it may hold reading errors

SCALE OPERATION

When using an INTERMEC Power Supply for Increased voltage, jumpers Inside the reader must be reset:

1. Disconnect reader from workstation and power.

2. Remove reader cover and [ocate jumpers J6 and J9 on PCB. 3. Reset reader [jumpers J6 and J9 to position 2-3.

4, Replace reader cover,

5. Connect power supply to reader and AC power.

6. Turn on workstation to power reader.

User-Provided External Power Supply

H you choose to provide your own source of external power, connections are made to the AS-232 subminlature connector on the rear of the reader. Connector pin assignment Is Ilsted in Table 6-1. Reset reader jumpars, prapare the connector, and observe reader power limits.

Jumpers

1. Disconnect reader from workstation and power.

2, Ramove reader cover and locate jumpers J& and JS on PCB, 3. Reset Jumpers J6 and J9 to position 2-1.

4, Replace reader cover.

Power Supply Cable and Connector 5. Refer to Table 6-1 for connector pin assignments for pins 18 and 25. Pin 18 is located at jumper JS; pin 25 Is located at jumper J6.

Power Supply

6. External power must not exceed £12 volts.

7. Connect external power supply to reader and AC power. 8. Connect reader to workstation.

9. Turn on workstation to power reader.

Page 6-6 ©1988 INTERMEC Corporation

Page 114 read from a scan by OCR; it may hold reading errors

Auxillary Port Confiquration

After you have located the cable and connectors, cannect the scale to the reader.

AUXILIARY PORT CONFIGURATION

Configuration Parameters The following wedge reader parameters must be snabled or defined.

e Required Interface parameters: e Baud rata e Parity

© Number of data bits

« Numbar of stop bile

Requlrad Scale communication parameters: « Window Mode enabled

® Start and End of Window One defined e Window One EOM defined

« Message Timeout defined

Optional Scale communication parameters: © Window One Sollcitatlon defined

© Start and End of Window Two defined

® Window Two EOM defined

© Window Two Sollcitation defined

Follow the configuration steps In Table 6-3 incorporating the same functional changes you have already accomplished In Section 3. Definitions, directions, and labels are contalned in the table.

©1988 INTEAMEG Corporation Page 6-7

Page 115 read from a scan by OCR; it may hold reading errors

SCALE OPERATION

Configuration Checklist

Table 6-2 below contains a parameter configuration checklist. Use this to record your selections as you configure the AS-232 auxillary port. When you need to review the configuration of the auxiliary port, you can refer to this list.

Table 6-2 AS-232 Auxiliary Port Configuration Checklist

Parameter: Configuration:

Baud Rate

Parity

Data Bits

Stop Bits

RS-232 Mode

Message Timaoul

Window One Start End EOM

Window Two Start End EOM

Page 6-8 ©4988 INTERMEG Corporation