Page 28
9189 900 MHz RF Gateway User’s Manual
Entering Command Strings There are three ways to send command strings to the gateway. Use the method that best suits the situation. Entering commands from the host The host application can send command strings directly to any gateway in the radio frequency data collection (RFDC) network. Since the host cannot perform the initial configuration of a gateway, you can only use this method after the gateway is functional within the network. By using group addressing, the host can configure more than one gateway at a time. Keying in commands If the gateway is connected to a device with a keypad, such as a TRAKKER 944X, you can enter command strings directly from the keypad. Scanning in commands To set parameters one at a time, use the bar codes listed on the following pages. Some of the commands using variable data values require scanning more than one bar code. Note: Before using a reader to configure the gateway, ensure that the Preamble A, Preamble B, and Postamble C buffers are clear. Failure to clear these buffers before configuration will cause the gateway to report an error. Scan this label to clear the buffers: Clear Preamble A, Preamble B, Postamble C
*+.+++%* *+.+++%*
For example, scanning the labels for setting the RFNC/BRU Address places the gateway in Accumulate mode and enters the Enter Configuration and RFNC/BRU Address commands. You need to scan two numeric labels from the Full ASCII chart in Appendix A that correspond to the desired RFNC/BRU Address. The reader is taken out of Configuration and Accumulate modes. The complete command string is transmitted to the gateway. Hint: To make the configuration process quick and consistent, print a single bar code label that contains all the software configuration parameters. This allows all parameters to be set with a single scan. If possible, affix this label to the side of the gateway so it is always available.
1-20
Page 29
9189 RF Gateway
1
About 9189 Commands This section describes the 9189 software commands. Note: The Code 39 bar code labels in this chapter show an asterisk (*) at the beginning and end of the human-readable interpretation to represent the start and stop codes. If you are creating your own Code 39 bar code labels, you may not have to include the asterisks because your bar code utility may automatically supply them as the start/stop code.
Entering Configuration Mode Purpose:
Puts the gateway in Configuration mode. Must be the first characters in a batch configuration string.
Format:
..$+
Exiting Configuration Mode Purpose:
Exits Configuration mode and triggers a soft reset to update all parameters. Any data following this command will be ignored.
Format:
$-
Default Configuration Purpose:
Resets all parameters to their factory-set values and invokes diagnostic procedures. Note: All data buffered in memory will be lost when the Default Configuration command is executed.
Format:
..$+.+
Scan:
*..$+.+* *..$+.+*
1-21
Page 30
9189 900 MHz RF Gateway User’s Manual
Resetting Software Drivers Purpose:
Reinitializes all software drivers.
Format:
..$+$-
Scan:
*..$+$-* *..$+$-*
Listing the Current Configuration Purpose:
Displays the current values of all radio configuration parameters. The output is of the following format: 053441 Ver x.x RHxxxRLxxRMxxRQxxRSxRTxx RUxRVxRWxxxRXxxxRYxR0xR1 xR2xR3xR4xR5xR6xNM02xNM0 3x
Each parameter is described below.
1-22
RHxxx
Local address
RLxx
Retry Limit
RMxxx
Acknowledgment delay
RQxx
POL/SEL delay
RSx
Error Report mode
RTxx
RFNC address
RUx
Repeat Count
RVx
Frequency over which the device communicates.
RWxxx
Network ID
RXxxx
RF Duty Cycle
RYx
Hardware Duty Cycle
R0x-R6x
Enables or disables the channel the device can search for when its channel (RVx) is busy.
NM02x
RF Loopback Mode enable
NM03x
Time Broadcast Receipt enable
Page 31
9189 RF Gateway
Format:
1
..$+RZ
Scan: Exit Full ASCII
*-$* *-$*
List Configuration
*..$+RZ$-* *..$+RZ$-*
Acknowledgment Delay Purpose:
Whenever the gateway sends a frame that requires a response from the controller, a timeout is set. The expected response must be received within this timeout.
Format:
RMdata Where values for data are 0 to 100. The value of data is multiplied by 5 to determine the delay in milliseconds.
Default: Scan:
0 (optimizes setting to 40 ms) 1. Scan these labels Exit Full ASCII/Enter Accumulate
*-$+/* *-$+/*
Acknowledgment Delay
*..$+RM* *..$+RM*
2. Scan a numeric value for data from the Full ASCII chart in Appendix A, or enter a number from the keypad of the data collection device.
1-23
Page 32
9189 900 MHz RF Gateway User’s Manual
3. Scan these labels. Exit Configuration
*$-* *$-*
Exit Accumulate
*-/* *-/*
Channel Select Purpose:
Determines the channel over which the 9189 communicates with the controller. The channel selected must match the one established for the 9189 on the base radio unit. Note: RVdata determines the initial channel over which the gateway will send data. The Rdata command determines additional channels over which the gateway can channel search.
Format:
RVdata Where values for data are 0 through 6, corresponding to these frequencies:
Default: Scan:
0
924 MHz
4
912 MHz
1
921 MHz
5
909 MHz
2
918 MHz
6
906 MHz
3
915 MHz
0 (924 MHz) 1. Scan this label. Exit Full ASCII
*-$* *-$*
1-24
Page 33
9189 RF Gateway
1
2. Scan one of the labels below. 924 MHz
*..$+RV0$-* *..$+RV0$-* 921 MHz
*..$+RV1$-* *..$+RV1$-* 918 MHz
*..$+RV2$-* *..$+RV2$-* 915 MHz
*..$+RV3$-* *..$+RV3$-* 912 MHz
*..$+RV4$-* *..$+RV4$-* 909 MHz
*..$+RV5$-* *..$+RV5$-* 906 MHz
*..$+RV6$-* *..$+RV6$-*
Downline POL/SEL Delay Purpose:
Specifies the length of time the gateway will wait between invoking communication events.
Format:
RQdata Where values of data are 0 to 50. The value of data is multiplied by 5 to obtain the delay in milliseconds.
Default:
0 (40 ms)
1-25
Page 34
9189 900 MHz RF Gateway User’s Manual
Scan:
1. Scan these labels. Exit Full ASCII/Enter Accumulate
*-$+/* *-$+/*
Downline POL/SEL Delay
*..$+RQ* *..$+RQ*
2. Scan a numeric value for data from the Full ASCII chart in Appendix A, or enter a number from the keypad of the data collection device. 3. Scan these labels. Exit Configuration
*$-* *$-*
Exit Accumulate
*-/* *-/*
Channel Search Purpose:
Determines the channel that the gateway can switch to if its own channel is busy.
Format:
Rdata1data2 Values for data1 are 0 through 6, and correspond to the following: 0 1 2 3
924 MHZ 921 MHZ 918 MHZ 915 MHZ
4 5 6
912 MHZ 909 MHZ 906 MHZ
Values for data2 are 0 and 1, and correspond to the following: 0 1 Default:
1-26
Disable the channel Enable the channel
0 for all channels
Page 35
9189 RF Gateway
Scan:
1
1. Scan the Exit Full ASCII label. Exit Full ASCII
*-$* *-$*
2. Scan the appropriate bar code. Enable Channels
Disable Channels
924 MHz
924 MHz
*..$+R01$-*
*..$+R00$-*
*..$+R01$-*
*..$+R00$-*
921 MHz
921 MHz
*..$+R11$-*
*..$+R10$-*
*..$+R11$-*
*..$+R10$-*
918 MHz
918 MHz
*..$+R21$-*
*..$+R20$-*
*..$+R21$-*
*..$+R20$-*
915 MHz
915 MHz
*..$+R31$-*
*..$+R30$-*
*..$+R31$-*
*..$+R30$-*
912 MHz
912 MHz
*..$+R41$-*
*..$+R40$-*
*..$+R41$-*
*..$+R40$-*
909 MHz
909 MHz
*..$+R51$-*
*..$+R50$-*
*..$+R51$-*
*..$+R50$-*
906 MHz
906 MHz
*..$+R61$-* *..$+R61$-*
*..$+R60$-*
*..$+R60$-*
1-27
Page 36
9189 900 MHz RF Gateway User’s Manual
Duty Cycle Percent Purpose:
The gateway can be duty cycled to conserve battery power. The longer the duty cycle, the longer the response delays the operator will experience. Duty cycle is expressed against a time base set by the RF Duty Cycle Period. For example, if the RF Duty Cycle Period is set to 1 second, a 30% duty cycle means the hardware is on for 300 ms and then off for 700 ms.
Format:
RYdata Where values for data are 0 through 9. 0
100% duty cycle on
5
50% duty cycle on
1
90% duty cycle on
6
40% duty cycle on
2
80% duty cycle on
7
30% duty cycle on
3
70% duty cycle on
8
20% duty cycle on
4
60% duty cycle on
9
10% duty cycle on
Default:
5 (50% duty cycle off)
Scan:
1. Scan these labels. Exit Full ASCII/Enter Accumulate
*-$+/* *-$+/*
RF Hardware Duty Cycle
*..$+RY* *..$+RY*
2. Scan a numeric value for data from the Full ASCII chart in Appendix A, or enter a number from the keypad of the data collection device. 3. Scan these labels. Exit Configuration
*$-* *$-*
Exit Accumulate
*-/* *-/*
1-28