For the Intermec 9189
Page 37
9189 RF Gateway
1
Duty Cycle Period Purpose:
Specifies the duty cycle period.
Format:
RXdata Where values for data are numeric with the range 1 through 100. The value of data is multiplied by 100 to obtain the RF Duty Cycle period in milliseconds.
Default: Scan:
10 (1 second) 1. Scan these labels. Exit Full ASCII/Enter Accumulate
*-$+/* *-$+/*
RF Duty Cycle Period
*..$+RX* *..$+RX*
2. Scan a numeric value for data from the Full ASCII chart in Appendix A, or enter a number from the keypad of the data collection device. 3. Scan these labels. Exit Configuration
*$-* *$-*
Exit Accumulate
*-/* *-/*
Loopback Purpose:
Causes all messages transmitted from the controller to loop back to the controller. Messages sent from a data collection device continue to transmit to the controller.
Format:
NM02data
1-29
Page 38
9189 900 MHz RF Gateway User’s Manual
Where values for data are 0 through 1. 0 1 Default:
Disabled Enabled
0
Network ID Purpose:
Each data collection device must have a Network ID so it knows which specific controller/BRU combination to communicate with.
Format:
RWdata Where values for data are 000 through 254.
Default: Scan:
000 1. Scan these labels. Exit Full ASCII/Enter Accumulate
*-$+/* *-$+/*
Network ID
*..$+RW* *..$+RW*
2. Scan a numeric value for data from the full ASCII chart in Appendix A, or enter a number from the keypad of the device. 3. Scan these labels. Exit Configuration
*$-* *$-*
Exit Accumulate
*-/* *-/*
1-30
Page 39
9189 RF Gateway
1
Repeat Count Purpose:
For Intermec version 1.x RF systems only. Specifies the maximum number of repeat hops that are allowed. This prevents a message from being repeated indefinitely.
Format:
RUdata Where values for data are numeric with a range of 0 to 7.
Default: Scan:
0 (no repeats) 1. Scan these labels. Exit Full ASCII/Enter Accumulate
*-$+/* *-$+/*
RF Repeat Count
*..$+RU* *..$+RU*
2. Scan a numeric value for data from the Full ASCII chart in Appendix A, or enter a number from the keypad of the data collection device. 3. Scan these labels. Exit Configuration
*$-* *$-*
Exit Accumulate
*-/* *-/*
1-31
Page 40
9189 900 MHz RF Gateway User’s Manual
Retry Limit Purpose:
Sets the number of times the gateway will attempt to send a packet. With each attempt, a counter is incremented. Once the counter reaches the retry limit, an error is reported.
Format:
RLdata Where values for data are 0 through 15.
Default: Scan:
0 (optimizes setting to 3 retries) 1. Scan these labels. Exit Full ASCII/Enter Accumulate
*-$+/* *-$+/*
RF Retry Limit
*..$+RL* *..$+RL*
2. Scan a numeric value for data from the Full ASCII chart in Appendix A, or enter a number from the keypad of the data collection device. 3. Scan these labels. Exit Configuration
*$-* *$-*
Exit Accumulate
*-/* *-/*
1-32
Page 41
9189 RF Gateway
1
RFNC/BRU Address Purpose:
For Intermec version 1.x RF systems only. Specifies which RFNC and BRU address the gateway communicates with. There are 64 BRU addresses; each network controller can support two BRUs.
Format:
RTdata Where values for data are numeric with a value of 0 through 63, corresponding to the addresses listed in the table on the next page.
Default:
0 (RFNC 0, BRU 0)
Scan:
1. Scan these labels. Exit Full ASCII/Enter Accumulate
*-$+/* *-$+/*
RFNC/BRU Address
*..$+RT* *..$+RT*
2. Scan a numeric decimal value for data from the Full ASCII chart in Appendix A, or enter a number from the keypad of the data collection device. 3. Scan these labels. Exit Configuration
*$-* *$-*
Exit Accumulate
*-/* *-/*
1-33
Page 42
9189 900 MHz RF Gateway User’s Manual
Controller/BRU Addresses
<data>
Hex Address
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
A1 A2 A3 A4 A5 A6 A7 A8 A9 AA AB AC AD AE AF B0 B1 B2 B3 B4 B5 B6 B7 B8 B9 BA BB BC BD BE BF C0
1-34
Controlle r
BRU Port
<data>
Hex Address
0 0 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 13 13 14 14 15 15
Dnln 1 Dnln 2 Dnln 1 Dnln 2 Dnln 1 Dnln 2 Dnln 1 Dnln 2 Dnln 1 Dnln 2 Dnln 1 Dnln 2 Dnln 1 Dnln 2 Dnln 1 Dnln 2 Dnln 1 Dnln 2 Dnln 1 Dnln 2 Dnln 1 Dnln 2 Dnln 1 Dnln 2 Dnln 1 Dnln 2 Dnln 1 Dnln 2 Dnln 1 Dnln 2 Dnln 1 Dnln 2
32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63
C1 C2 C3 C4 C5 C6 C7 C8 C9 CA CB CC CD CE CF D0 D1 D2 D3 D4 D5 D6 D7 D8 D9 DA DB DC DD DE DF E0
Controlle r
BRU Port
16 16 17 17 18 18 19 19 20 20 21 21 22 22 23 23 24 24 25 25 26 26 27 27 28 28 29 29 30 30 31 31
Dnln 1 Dnln 2 Dnln 1 Dnln 2 Dnln 1 Dnln 2 Dnln 1 Dnln 2 Dnln 1 Dnln 2 Dnln 1 Dnln 2 Dnln 1 Dnln 2 Dnln 1 Dnln 2 Dnln 1 Dnln 2 Dnln 1 Dnln 2 Dnln 1 Dnln 2 Dnln 1 Dnln 2 Dnln 1 Dnln 2 Dnln 1 Dnln 2 Dnln 1 Dnln 2 Dnln 1 Dnln 2
Page 43
9189 RF Gateway
1
RFPC Error Reporting Mode Purpose:
Format:
Specifies whether the gateway should report internal errors to the network controller or the data collection device. These error messages can be reported by the gateway: Error Message
Code
Xbar NAK Retry Error
!:A
Xbar Bad LRC Error
!:B
Xbar Bad SOM Error
!:C
Xbar Bad RX Data
!:D
Xbar Overflow Error
!:E
Xbar Parity Error
!:F
Xbar Framing Error
!:G
Xbar Timeout Error
!:H
Xbar POL Retry Error
!:I
Xbar SEL Retry Error
!:J
Xbar Protocol Error
!:K
RFDL Underrun Error
!:O
RF Output Buffer Full
!:P
RF Input Buffer Full
!:Q
Bad Configuration Data
!:R
RFPC Default/Reset
!:S
Low NiCad Battery
!:T
Low Lithium Battery
!:U
RFPC Illegal Reset
!:V
RSdata Where values for data are 0 through 3.
Default:
0
Disabled
1
Error beep and protected message to data collection device
2
Data collection device receives coded message
3
Host receives coded message
0 (Disabled)
1-35
Page 44
9189 900 MHz RF Gateway User’s Manual
Scan:
1. Scan this label. Exit Full ASCII
*-$* *-$*
2. Scan one of these labels. Disabled
*..$+RS0$-* *..$+RS0$-*
Error Beep and Protected Message to Device
*..$+RS1$-* *..$+RS1$-*
Device Receives Coded Message
*..$+RS2$-* *..$+RS2$-*
Host Receives Coded Message
*..$+RS3$-* *..$+RS3$-*
Time Broadcast Receipt Purpose:
Enables or disables the ability of the gateway to receive the time broadcast from the controller.
Format:
NM03data Where values for data are 0 through 1. 0 1
Default:
1-36
0
Disabled Enabled
Page 45
A Appendix A