Page 19
9189 RF Gateway
1
To configure the gateway 1. Set the DIP switches. For help, see “Understanding the DIP Switches” later in this chapter. 2. Apply power through either the internal NiCad battery pack or the external power supply. For help, see “Supplying Power for the Gateway” earlier in this chapter. 3. Connect the data collection device. For help, see “Cables” earlier in this chapter. 4. Make sure these parameters on the device match those configured for the gateway: •
Polling Mode D protocol
•
19200, 9600, 4800, or 2400 baud
5. Set the software parameters. For help, see “Setting the Software Parameters” later in this chapter. Note: If a TRAKKER 94XX is connected to the gateway using Polling Mode D, enable the Check CTS option.
Setting the RF Channels To set the RF Channels on the gateway you need to configure both the DIP switches and software. This procedure ensures that the unit will still access the right channel if the gateway’s RAM is cleared.
1-11
Page 20
9189 900 MHz RF Gateway User’s Manual
Understanding the DIP Switches Inside the gateway are two banks of DIP switches, SW2 and SW3. These DIP switches control settings such as addresses and the RF channel. For the gateway DIP switches, off indicates the switch is in the up position. On indicates the switch is in the down position. Refer to this figure. 9189 DIP Switches off on
SW2
S
W
3
S
W
2
SW3
DIP Switch Locations
9189U.005
Setting the DIP Switches Caution Disconnect the external power supply before removing the internal battery pack. Failure to comply may result in equipment damage. Conseil Déconnectez la source de courant externe avant d'enlever le jeu de piles interne, faute de quoi vous risquez d’endommager l’équipement.
1-12
Page 21
9189 RF Gateway
1
To reset the DIP switches 1. Turn the gateway’s power switch off. 2. If an external power supply is being used, disconnect it. 3. Remove the internal NiCad battery pack by loosening the screw on the bottom of the gateway. The DIP switches are located in the rear of the battery compartment. 4. Use a pointed object to move switch 1 on SW2 to the on position. 5. Replace the NiCad battery pack and reconnect any equipment removed in the previous steps. 6. Turn the gateway’s power switch on. All software parameters are now reset. 7. Turn the gateway’s power switch off and remove the battery pack as described in Steps 1 through 3. 8. Use a pointed object to move switch 1 on SW2 to the off position. 9. Set DIP switches to any new configuration. 10. Turn the gateway’s power switch on. Note: After you change your DIP switch settings, you need to set your software parameters.
Restoring the Default Configuration 1. Turn the gateway’s power switch off. 2. If an external power supply is being used, disconnect it. 3. Remove the internal NiCad battery pack by loosening the screw on the bottom of the gateway. The DIP switches are located in the rear of the battery compartment. 4. Use a pointed object to move switch 1 on SW2 to the on position. 5. Replace the NiCad battery pack and reconnect any equipment removed in the previous steps. 6. Turn the gateway’s power switch on. All software parameters are now reset.
1-13
Page 22
9189 900 MHz RF Gateway User’s Manual
RF Channel You need to set the RF channel using the DIP switches and the software command. Switches 2 through 4 on SW2 determine which of seven RF channels the gateway will operate on. For help, see “Channel Select” later in this chapter for the software command. SW2 Switches RF Channel
2
3
4
924 MHz off off off
921 MHz on off off
918 MHz off on off
915 MHz on on off
912 MHz off off on
909 MHz on off on
906 MHz off on on
Baud Rate Switches 5 and 6 of SW2 determine the baud rate at which the gateway communicates with the data collection device. There are four possible speeds. SW2 Switches Baud Rate
5
6
19200 off off
9600 off on
4800 on off
2400 on on
Protocol Switch 7 on SW2 determines the protocol of the data collection device. Set the switch to off for Polling Mode D.
Data Bits Switch 8 on SW2 sets the number of data bits for the gateway’s communication. Set the switch to off for seven data bits and on for eight. If the device is configured to Polling Mode D, the gateway must be set to seven data bits.
1-14
Page 23
9189 RF Gateway
1
Address Switches 1 through 7 on SW3 set the gateway’s address. The following tables list all 128 addresses and the corresponding switch settings. 9189 Address Switch Settings ADDRESS LOCAL
HOST
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
Ú............ SW3 SWITCHES ............¿ 1
2
3
4
5
6
7
MA
OFF
OFF
OFF
OFF
OFF
OFF
OFF
MB
ON
OFF
OFF
OFF
OFF
OFF
OFF
MC
OFF
ON
OFF
OFF
OFF
OFF
OFF
MD
ON
ON
OFF
OFF
OFF
OFF
OFF
ME
OFF
OFF
ON
OFF
OFF
OFF
OFF
MF
ON
OFF
ON
OFF
OFF
OFF
OFF
MG
OFF
ON
ON
OFF
OFF
OFF
OFF
MH
ON
ON
ON
OFF
OFF
OFF
OFF
MI
OFF
OFF
OFF
ON
OFF
OFF
OFF
MJ
ON
OFF
OFF
ON
OFF
OFF
OFF
MK
OFF
ON
OFF
ON
OFF
OFF
OFF
ML
ON
ON
OFF
ON
OFF
OFF
OFF
MM
OFF
OFF
ON
ON
OFF
OFF
OFF
MN
ON
OFF
ON
ON
OFF
OFF
OFF
MO
OFF
ON
ON
ON
OFF
OFF
OFF
MP
ON
ON
ON
ON
OFF
OFF
OFF
MQ
OFF
OFF
OFF
OFF
ON
OFF
OFF
MR
ON
OFF
OFF
OFF
ON
OFF
OFF
MS
OFF
ON
OFF
OFF
ON
OFF
OFF
MT
ON
ON
OFF
OFF
ON
OFF
OFF
MU
OFF
OFF
ON
OFF
ON
OFF
OFF
MV
ON
OFF
ON
OFF
ON
OFF
OFF
MW
OFF
ON
ON
OFF
ON
OFF
OFF
MX
ON
ON
ON
OFF
ON
OFF
OFF
MY
OFF
OFF
OFF
ON
ON
OFF
OFF
MZ
ON
OFF
OFF
ON
ON
OFF
OFF
M0
OFF
ON
OFF
ON
ON
OFF
OFF
M1
ON
ON
OFF
ON
ON
OFF
OFF
M2
OFF
OFF
ON
ON
ON
OFF
OFF
M3
ON
OFF
ON
ON
ON
OFF
OFF
M4
OFF
ON
ON
ON
ON
OFF
OFF
M5
ON
ON
ON
ON
ON
OFF
OFF
NA
OFF
OFF
OFF
OFF
OFF
ON
OFF
NB
ON
OFF
OFF
OFF
OFF
ON
OFF
NC
OFF
ON
OFF
OFF
OFF
ON
OFF
ND
ON
ON
OFF
OFF
OFF
ON
OFF
NE
OFF
OFF
ON
OFF
OFF
ON
OFF
NF
ON
OFF
ON
OFF
OFF
ON
OFF
NG
OFF
ON
ON
OFF
OFF
ON
OFF
NH
ON
ON
ON
OFF
OFF
ON
OFF
NI
OFF
OFF
OFF
ON
OFF
ON
OFF
NJ
ON
OFF
OFF
ON
OFF
ON
OFF
1-15
Page 24
9189 900 MHz RF Gateway User’s Manual
9189 Address Switch Settings (continued) ADDRESS LOCAL
HOST
43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88
1-16
Ú............ SW3 SWITCHES ............¿ 1
2
3
4
5
6
7
NK
OFF
ON
OFF
ON
OFF
ON
OFF
NL
ON
ON
OFF
ON
OFF
ON
OFF
NM
OFF
OFF
ON
ON
OFF
ON
OFF
NN
ON
OFF
ON
ON
OFF
ON
OFF
NO
OFF
ON
ON
ON
OFF
ON
OFF
NP
ON
ON
ON
ON
OFF
ON
OFF
NQ
OFF
OFF
OFF
OFF
ON
ON
OFF
NR
ON
OFF
OFF
OFF
ON
ON
OFF
NS
OFF
ON
OFF
OFF
ON
ON
OFF
NT
ON
ON
OFF
OFF
ON
ON
OFF
NU
OFF
OFF
ON
OFF
ON
ON
OFF
NV
ON
OFF
ON
OFF
ON
ON
OFF
NW
OFF
ON
ON
OFF
ON
ON
OFF
NX
ON
ON
ON
OFF
ON
ON
OFF
NY
OFF
OFF
OFF
ON
ON
ON
OFF
NZ
ON
OFF
OFF
ON
ON
ON
OFF
N0
OFF
ON
OFF
ON
ON
ON
OFF
N1
ON
ON
OFF
ON
ON
ON
OFF
N2
OFF
OFF
ON
ON
ON
ON
OFF
N3
ON
OFF
ON
ON
ON
ON
OFF
N4
OFF
ON
ON
ON
ON
ON
OFF
N5
ON
ON
ON
ON
ON
ON
OFF
OA
OFF
OFF
OFF
OFF
OFF
OFF
ON
OB
ON
OFF
OFF
OFF
OFF
OFF
ON
OC
OFF
ON
OFF
OFF
OFF
OFF
ON
OD
ON
ON
OFF
OFF
OFF
OFF
ON
OE
OFF
OFF
ON
OFF
OFF
OFF
ON
OF
ON
OFF
ON
OFF
OFF
OFF
ON
OG
OFF
ON
ON
OFF
OFF
OFF
ON
OH
ON
ON
ON
OFF
OFF
OFF
ON
OI
OFF
OFF
OFF
ON
OFF
OFF
ON
OJ
ON
OFF
OFF
ON
OFF
OFF
ON
OK
OFF
ON
OFF
ON
OFF
OFF
ON
OL
ON
ON
OFF
ON
OFF
OFF
ON
OM
OFF
OFF
ON
ON
OFF
OFF
ON
ON
ON
OFF
ON
ON
OFF
OFF
ON
OO
OFF
ON
ON
ON
OFF
OFF
ON
OP
ON
ON
ON
ON
OFF
OFF
ON
OQ
OFF
OFF
OFF
OFF
ON
OFF
ON
OR
ON
OFF
OFF
OFF
ON
OFF
ON
OS
OFF
ON
OFF
OFF
ON
OFF
ON
OT
ON
ON
OFF
OFF
ON
OFF
ON
OU
OFF
OFF
ON
OFF
ON
OFF
ON
OV
ON
OFF
ON
OFF
ON
OFF
ON
OW
OFF
ON
ON
OFF
ON
OFF
ON
OX
ON
ON
ON
OFF
ON
OFF
ON
Page 25
9189 RF Gateway
1
9189 Address Switch Settings (continued) ADDRESS LOCAL
HOST
89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128
Ú............ SW3 SWITCHES ............¿ 1
2
3
4
5
6
7
OY
OFF
OFF
OFF
ON
ON
OFF
ON
OZ
ON
OFF
OFF
ON
ON
OFF
ON
O0
OFF
ON
OFF
ON
ON
OFF
ON
O1
ON
ON
OFF
ON
ON
OFF
ON
O2
OFF
OFF
ON
ON
ON
OFF
ON
O3
ON
OFF
ON
ON
ON
OFF
ON
O4
OFF
ON
ON
ON
ON
OFF
ON
O5
ON
ON
ON
ON
ON
OFF
ON
PA
OFF
OFF
OFF
OFF
OFF
ON
ON
PB
ON
OFF
OFF
OFF
OFF
ON
ON
PC
OFF
ON
OFF
OFF
OFF
ON
ON
PD
ON
ON
OFF
OFF
OFF
ON
ON
PE
OFF
OFF
ON
OFF
OFF
ON
ON
PF
ON
OFF
ON
OFF
OFF
ON
ON
PG
OFF
ON
ON
OFF
OFF
ON
ON
PH
ON
ON
ON
OFF
OFF
ON
ON
PI
OFF
OFF
OFF
ON
OFF
ON
ON
PJ
ON
OFF
OFF
ON
OFF
ON
ON
PK
OFF
ON
OFF
ON
OFF
ON
ON
PL
ON
ON
OFF
ON
OFF
ON
ON
PM
OFF
OFF
ON
ON
OFF
ON
ON
PN
ON
OFF
ON
ON
OFF
ON
ON
PO
OFF
ON
ON
ON
OFF
ON
ON
PP
ON
ON
ON
ON
OFF
ON
ON
PQ
OFF
OFF
OFF
OFF
ON
ON
ON
PR
ON
OFF
OFF
OFF
ON
ON
ON
PS
OFF
ON
OFF
OFF
ON
ON
ON
PT
ON
ON
OFF
OFF
ON
ON
ON
PU
OFF
OFF
ON
OFF
ON
ON
ON
PV
ON
OFF
ON
OFF
ON
ON
ON
PW
OFF
ON
ON
OFF
ON
ON
ON
PX
ON
ON
ON
OFF
ON
ON
ON
PY
OFF
OFF
OFF
ON
ON
ON
ON
PZ
ON
OFF
OFF
ON
ON
ON
ON
P0
OFF
ON
OFF
ON
ON
ON
ON
P1
ON
ON
OFF
ON
ON
ON
ON
P2
OFF
OFF
ON
ON
ON
ON
ON
P3
ON
OFF
ON
ON
ON
ON
ON
P4
OFF
ON
ON
ON
ON
ON
ON
P5
ON
ON
ON
ON
ON
ON
ON
1-17
Page 26
9189 900 MHz RF Gateway User’s Manual
Setting the Software Parameters In addition to the DIP switches, the gateway uses software configuration parameters. Since the gateway has no direct user interface, the software parameters must be entered from the host or from a data collection device. The device can send configuration commands with an input device such as a scanner, or with an IRL program. Default values for all software parameters are listed in the 9189 Default Parameters table on the next page.
Using a Data Collection Device You cannot use the gateway to communicate with the RF system and host computer until you configure its parameters. Therefore, to program the software parameters, you must connect the gateway to a reader or other data collection device that can provide input to the gateway. This device may be any of these Intermec products: •
JANUS 2010 Hand-Held Data Collection Computer
•
944X Portable Reader Series
•
9460 Portable Reader
•
951X Online Reader Series
•
9540 Industrial Terminal
•
9550 Transaction Manager
•
9560 Time and Attendance Terminal
Once the gateway is configured, you can remove the reader and connect the gateway to any other device. 9189 Default Parameters
1-18
Parameter
Default
Acknowledgment Delay
0 (40 ms)
Channel Search
0, 0 (924 MHz, disabled)
Channel Select*
0 (924 MHz)
Downline POL/SEL Delay
0 (40 ms)
Duty Cycle Percent
5 (50% duty cycle on)
Duty Cycle Period
10 (1 second)
Local Address*
0 (disabled)
Loopback
0 (disabled)
Network ID
000
Page 27
9189 RF Gateway
1
9189 Default Parameters (continued) Parameter
Default
Repeat Count
0 (no repeats)
Retry Limit
0 (3 retries)
RFNC/BRU Address
0 (controller 0, BRU 0)
RFPC Error Reporting Mode
0 (disabled)
Time Broadcast Receipt *switch dependent
0 (disabled)
Using Configuration Command Strings You can set the software parameters by sending configuration command strings to the gateway.
Formatting Command Strings All command strings, whether they are from the host or a data collection device, must adhere to a specific format: 1. Before you enter a command string, you must put the gateway into Configuration mode by entering the Enter Configuration command (..$+). 2. Enter the configuration command and applicable data. For example, to set the hardware duty cycle to 60%, the command is RY6. 3. Terminate the string with the Exit Configuration command ($-). Combining these three components produces a string similar to the following: ..$+RY6$-
The command string may contain more than one parameter. For example, to set the hardware duty cycle to 60% and the retry limit to 4, construct the following string: ..$+RY6RL4$-
1-19