Page 10
Page 11
9189 RF Gateway
1
Learning About the 9189 RF Gateway The 9189 RF Gateway provides non RF devices, such as printers, with the ability to send data over the RF channels in your data collection network. The gateway adds RF capability with all the features, without affecting the performance of the device. Some of the Intermec devices commonly used with the gateway are: •
JANUS 2010 Hand-Held Data Collection Computer
•
94XX Portable Readers
•
951X Online Reader Series
•
9540 Industrial Terminal
•
9550 Transaction Manager
•
9560 Time and Attendance Terminal
•
86XX Printer Series
•
4XXX Printer Series
•
3XXX Printer Series
The gateway determines whether or not a data collection device is connected and properly configured by continuously polling the devices. If the device does not respond after six polling attempts, the gateway lowers its operating power, but continues polling the data collection devices. If a device eventually responds, full power and RF communications can begin.
1-3
Page 12
9189 900 MHz RF Gateway User’s Manual
Understanding the Gateway Components This figure shows the components of the gateway. Four status LEDs, a RS-232 interface connector, and the power switch are located on the top of the gateway. You can access the rechargeable NiCad batteries through the lower portion of the unit. 9189 Gateway Components Antenna
Power Switch RS-232 Port Interface
I
ON
O
OFF
®
TX
FAULT
DATA
9189 CONNECT
Status Lights
9189U.001
CAUTION
Caution The antenna must be attached before turning on the gateway. The internal radio could be damaged if the antenna is not attached. Conseil Si l'antenna n'est pas attachée avant que la gateway soit mise sous tension, la radio interne peut être endommagée.
1-4
Page 13
9189 RF Gateway
1
Understanding the Gateway Status LEDs The gateway has four status LEDs. During power up and self tests, all LEDs are on. If all tests pass, the LEDs will show the status descrubed in the 9189 Status LEDs table. If any of the self tests fail, the LEDs blink in one of the patterns listed in the 9189 LED Patterns table. 9189 Status LEDs LED
Description
Connect
Lights when the gateway has established communications with the 9180 controller. Turns off whenever the gateway cannot transmit to the controller.
Data
Lights when the gateway has data stored in its buffer.
Fault
Flashes when an error condition has been detected.
Tx
Lights when the gateway is transmitting data.
9189 LED Patterns Fault
Connect
Data
Fault
Tx
ROM Test blinking blinking blinking blinking
RAM Test blinking blinking blinking off
Internal RAM blinking blinking off blinking
CAUTION
Caution Do not turn the gateway off when the Data LED is on. Doing so may result in erroneous communications between the gateway and the rest of the system. Conseil N'éteignez pas la gateway lorsque la diode électroluminescente Données est allumée. Si vous l'éteignez, vous risquez de provoquer des communications erronées entre la gateway et le reste du système.
1-5
Page 14
9189 900 MHz RF Gateway User’s Manual
About the RS-232 Port Interface The gateway connects to other devices with a 10-pin, RS-232 interface. This table lists the pin assignments for the interface. Pin
Function
Pin
Function
1
Shield Ground
4
Request to Send
2
RFG Received Data
5
Clear to Send
3
RFG Transmitted Data
7
Ground
Supplying Power for the Gateway The gateway is powered by an internal NiCad battery or an external power supply. The NiCad battery allows the gateway to be used with portable data collection devices. However, if the gateway is connected to a stationary device such as a printer, you should use the external power supply.
Installing the Internal Battery Pack The internal battery pack contains NiCad batteries that you can recharge using Intermec’s battery pack charger (40ZA02). Battery life is dependent on the gateway’s activity. If the gateway transmits frequently, the batteries will drain faster. Typically, a fully charged NiCad pack will last 8 hours when the gateway is operating at a 50% duty cycle. Caution The internal battery pack must be installed in the gateway when using an external power supply. Failure to comply may result in equipment damage. Conseil Le jeu de piles interne doit être installé dans la gateway lors de l'utilisation d'une source de courant externe. Si ce n'est pas le cas, vous risquez d'endommager l'équipement.
1-6
Page 15
9189 RF Gateway
1
To install the battery pack •
Position the pack as shown in this figure and tighten the screw.
Battery Pack
9189U.002
Connecting the External Power Supply An external power supply can be attached to the connector on the side of the gateway, as shown in the figure on the next page. These Intermec power supplies are appropriate for use with the gateway: •
120 VAC, 50/60 Hz (Intermec P/N 042684)
•
100 VAC, 50/60 Hz (Intermec P/N 043230)
•
220 VAC, 50/60 Hz (Intermec P/N 045652)
Caution The internal battery pack must be installed in the gateway when using an external power supply. Failure to comply may result in equipment damage. Conseil Le jeu de piles interne doit être installé dans la gateway lors de l'utilisation d'une source de courant externe. Si ce n'est pas le cas, vous risquez d'endommager l'équipement.
1-7
Page 16
9189 900 MHz RF Gateway User’s Manual
Connecting an External Supply
TX
®
FA UL T DA TA
91
89
CO NN EC T
9189U.003
About the Accessories Several accessories are available for use with the gateway. Contact your local Intermec representative for ordering information.
Carrying Case When you use the gateway with a portable reader such as the Intermec TRAKKER 944X, you should protect it against accidental bumps and drops with a carrying case (Intermec P/N 055121). The belt of the case snaps around your waist to provide simple, out-of-the-way operation. A zippered flap lets you access the NiCad battery pack. Refer to the following figure.
1-8
Page 17
9189 RF Gateway
1
Since you cannot see the LEDs when you wear the case, you should configure the gateway to relay low battery warnings to the device. For help, see the RFPC Error Reporting Mode command. 9189 Carrying Case
TX
FAULT
DATA
Battery Pack Access
9189U.004
Cables Each cable has one end that connects to the RS-232 port interface on the gateway and the other end has a connector specific to the device. Refer to the user’s manual for the device for more information on RS-232 connections. To connect the gateway to a device, use one of the cables in this table. Part Number
Data Collection Device
059775
J2010 reader, optical link cable
060076
J2010 reader, JD2010A communications dock
057458
944X TRAKKER reader
054647
9460/9462 TRAKKER reader
054648
4XXX, 86XX, and 3XXX printers and 95XX readers
1-9
Page 18
9189 900 MHz RF Gateway User’s Manual
Configuring the Gateway You need to configure the gateway properly before it can communicate with the RFDC system. You can set the configuration parameters using a combination of DIP switches and software. Before you configure the gateway, you need this information: •
Local device address of the gateway. Note: The gateway’s default local address is mA. To avoid addressing conflicts with other devices, assign an address other than mA.
•
Initial RF channel. If you have two BRUs and you would like to be able to roam between them, you will need a second RF channel.
•
Device-specific parameters. For help, see “Software Parameters” later in this chapter.
This table lists all the parameters and the method for setting them. Note that the RF Channel is set with both switches and software.
1-10
Parameter
Switches
Software
Data Bits
Yes
No
Default Configuration
Yes
Yes
Downline POL/SEL Delay
No
Yes
Device Line Speed
Yes
No
Device Protocol
Yes
No
Local Address
Yes
No
RF Channel
Yes
Yes
RF Duty Cycle Period
No
Yes
RF Hardware Duty Cycle
No
Yes
RF Interactive Response Delay
No
Yes
RF Repeat Count
No
Yes
RF Retry Limit
No
Yes
RFNC/BRU Address
No
Yes
RFPC Error Reporting Mode
No
Yes