Page 10

This page is a scan with no text; see it in the PDF.

Page 11

9189 RF Gateway

1

Learning About the 9189 RF Gateway The 9189 RF Gateway provides non RF devices, such as printers, with the ability to send data over the RF channels in your data collection network. The gateway adds RF capability with all the features, without affecting the performance of the device. Some of the Intermec devices commonly used with the gateway are: •

JANUS 2010 Hand-Held Data Collection Computer

•

94XX Portable Readers

•

951X Online Reader Series

•

9540 Industrial Terminal

•

9550 Transaction Manager

•

9560 Time and Attendance Terminal

•

86XX Printer Series

•

4XXX Printer Series

•

3XXX Printer Series

The gateway determines whether or not a data collection device is connected and properly configured by continuously polling the devices. If the device does not respond after six polling attempts, the gateway lowers its operating power, but continues polling the data collection devices. If a device eventually responds, full power and RF communications can begin.

1-3

Page 12

9189 900 MHz RF Gateway User’s Manual

Understanding the Gateway Components This figure shows the components of the gateway. Four status LEDs, a RS-232 interface connector, and the power switch are located on the top of the gateway. You can access the rechargeable NiCad batteries through the lower portion of the unit. 9189 Gateway Components Antenna

Power Switch RS-232 Port Interface

I

ON

O

OFF

®

TX

FAULT

DATA

9189 CONNECT

Status Lights

9189U.001

CAUTION

Caution The antenna must be attached before turning on the gateway. The internal radio could be damaged if the antenna is not attached. Conseil Si l'antenna n'est pas attachée avant que la gateway soit mise sous tension, la radio interne peut être endommagée.

1-4

Page 13

9189 RF Gateway

1

Understanding the Gateway Status LEDs The gateway has four status LEDs. During power up and self tests, all LEDs are on. If all tests pass, the LEDs will show the status descrubed in the 9189 Status LEDs table. If any of the self tests fail, the LEDs blink in one of the patterns listed in the 9189 LED Patterns table. 9189 Status LEDs LED

Description

Connect

Lights when the gateway has established communications with the 9180 controller. Turns off whenever the gateway cannot transmit to the controller.

Data

Lights when the gateway has data stored in its buffer.

Fault

Flashes when an error condition has been detected.

Tx

Lights when the gateway is transmitting data.

9189 LED Patterns Fault

Connect

Data

Fault

Tx

ROM Test blinking blinking blinking blinking

RAM Test blinking blinking blinking off

Internal RAM blinking blinking off blinking

CAUTION

Caution Do not turn the gateway off when the Data LED is on. Doing so may result in erroneous communications between the gateway and the rest of the system. Conseil N'éteignez pas la gateway lorsque la diode électroluminescente Données est allumée. Si vous l'éteignez, vous risquez de provoquer des communications erronées entre la gateway et le reste du système.

1-5

Page 14

9189 900 MHz RF Gateway User’s Manual

About the RS-232 Port Interface The gateway connects to other devices with a 10-pin, RS-232 interface. This table lists the pin assignments for the interface. Pin

Function

Pin

Function

1

Shield Ground

4

Request to Send

2

RFG Received Data

5

Clear to Send

3

RFG Transmitted Data

7

Ground

Supplying Power for the Gateway The gateway is powered by an internal NiCad battery or an external power supply. The NiCad battery allows the gateway to be used with portable data collection devices. However, if the gateway is connected to a stationary device such as a printer, you should use the external power supply.

Installing the Internal Battery Pack The internal battery pack contains NiCad batteries that you can recharge using Intermec’s battery pack charger (40ZA02). Battery life is dependent on the gateway’s activity. If the gateway transmits frequently, the batteries will drain faster. Typically, a fully charged NiCad pack will last 8 hours when the gateway is operating at a 50% duty cycle. Caution The internal battery pack must be installed in the gateway when using an external power supply. Failure to comply may result in equipment damage. Conseil Le jeu de piles interne doit être installé dans la gateway lors de l'utilisation d'une source de courant externe. Si ce n'est pas le cas, vous risquez d'endommager l'équipement.

1-6

Page 15

9189 RF Gateway

1

To install the battery pack •

Position the pack as shown in this figure and tighten the screw.

Battery Pack

9189U.002

Connecting the External Power Supply An external power supply can be attached to the connector on the side of the gateway, as shown in the figure on the next page. These Intermec power supplies are appropriate for use with the gateway: •

120 VAC, 50/60 Hz (Intermec P/N 042684)

•

100 VAC, 50/60 Hz (Intermec P/N 043230)

•

220 VAC, 50/60 Hz (Intermec P/N 045652)

Caution The internal battery pack must be installed in the gateway when using an external power supply. Failure to comply may result in equipment damage. Conseil Le jeu de piles interne doit être installé dans la gateway lors de l'utilisation d'une source de courant externe. Si ce n'est pas le cas, vous risquez d'endommager l'équipement.

1-7

Page 16

9189 900 MHz RF Gateway User’s Manual

Connecting an External Supply

TX

®

FA UL T DA TA

91

89

CO NN EC T

9189U.003

About the Accessories Several accessories are available for use with the gateway. Contact your local Intermec representative for ordering information.

Carrying Case When you use the gateway with a portable reader such as the Intermec TRAKKER 944X, you should protect it against accidental bumps and drops with a carrying case (Intermec P/N 055121). The belt of the case snaps around your waist to provide simple, out-of-the-way operation. A zippered flap lets you access the NiCad battery pack. Refer to the following figure.

1-8

Page 17

9189 RF Gateway

1

Since you cannot see the LEDs when you wear the case, you should configure the gateway to relay low battery warnings to the device. For help, see the RFPC Error Reporting Mode command. 9189 Carrying Case

TX

FAULT

DATA

Battery Pack Access

9189U.004

Cables Each cable has one end that connects to the RS-232 port interface on the gateway and the other end has a connector specific to the device. Refer to the user’s manual for the device for more information on RS-232 connections. To connect the gateway to a device, use one of the cables in this table. Part Number

Data Collection Device

059775

J2010 reader, optical link cable

060076

J2010 reader, JD2010A communications dock

057458

944X TRAKKER reader

054647

9460/9462 TRAKKER reader

054648

4XXX, 86XX, and 3XXX printers and 95XX readers

1-9

Page 18

9189 900 MHz RF Gateway User’s Manual

Configuring the Gateway You need to configure the gateway properly before it can communicate with the RFDC system. You can set the configuration parameters using a combination of DIP switches and software. Before you configure the gateway, you need this information: •

Local device address of the gateway. Note: The gateway’s default local address is mA. To avoid addressing conflicts with other devices, assign an address other than mA.

•

Initial RF channel. If you have two BRUs and you would like to be able to roam between them, you will need a second RF channel.

•

Device-specific parameters. For help, see “Software Parameters” later in this chapter.

This table lists all the parameters and the method for setting them. Note that the RF Channel is set with both switches and software.

1-10

Parameter

Switches

Software

Data Bits

Yes

No

Default Configuration

Yes

Yes

Downline POL/SEL Delay

No

Yes

Device Line Speed

Yes

No

Device Protocol

Yes

No

Local Address

Yes

No

RF Channel

Yes

Yes

RF Duty Cycle Period

No

Yes

RF Hardware Duty Cycle

No

Yes

RF Interactive Response Delay

No

Yes

RF Repeat Count

No

Yes

RF Retry Limit

No

Yes

RFNC/BRU Address

No

Yes

RFPC Error Reporting Mode

No

Yes